708667
5
Zoom out
Zoom in
Vorherige Seite
1/8
Nächste Seite
Indicator
PCB Position
PCB Board
Dip Switches
TEST MODE WALK TESTis displayed.
Press to activate Walk Test. Walk Test Waiting…’ is displayed. Press the ARM button
on the Remote Control; Alarm Panel will beep and the type of the device and button will be on the
display. Press the other buttons on the Remote, as each button is pressed the Alarm Panel will beep
and show the button being pressed on the display. KEEP THE ALARM PANEL IN THE TEST MODE!
PIR Motion Sensor:
PIR Sensors are designed to detect movement.
Insert the 9 Volt battery. The PIR will warm-up during 2-3 minutes. The LED will flash. When it is ready
the LED stops. First check the house code: SW2; switch 1 8 (must be same as Remote Control). You
can divide your detectors over your total home in zones. You can set the alarm zone the PIR detector
will operate on, by switch the dip switches 1, 2 and 3 (of SW3; dipswitch 1-5) in the position according
schedule above. Mark which zone number on the PIR. For walk test mode you put dip 4 of SW3 On.
Dont forget to put back in Off. Test the PIR in the walk test mode. In normal mode the PIR will only send
a mew signal after being triggered after 2 minutes
The PIR sensor incorporates an anti-false alarm for where the Sensor might be affected by e.g. insects,
air temperature etc. We recommend high sensitivity, but in case of affection of (e.c. insects) , you can
adjust dip 5 of SW3 to Off: low sensitivity detection!
Door/window magnet:
The Magnetic Contact consists of two parts; a Detector and a Magnet. They are designed to be fitted
to doors or windows with the Magnet mounted on the moving/opening part.
Mounting the door/wind magnet:
Decide which doors/windows are to be protected by fitting Magnetic
Contact Detectors, (usually the front and back doors. Additional detectors
may also be fitted where required to other vulnerable doors or windows,
(e.g. garage, patio/conservatory doors etc).Ensure that the position selected
for the Magnetic Contact detector is within effective range of the Control Panel, (refer to
‘Testing the Control Panel & Remote Control’). Remove the battery holder, and mount the
detector using either the adhesive tape or screws. Fit the Magnet to the moving part of the door/window
opposite the Detector. Ensure that the parallel gap between the Magnet and Detector is less than 10mm
and that the arrow on the Magnet is pointing towards and aligned with the mark on the Detector.
Mounting the PIR motion sensor:
Household pets should not be allowed into an area protected by a PIR detector! Do not locate the
detector facing a window facing direct sunlight. PIR Detectors are not suitable for use in
conservatories. Do not locate the detector where it is exposed to ventilators. Do not locate the detector
DIP 1 DIP 2 DIP 3
Zone 1 OFF OFF OFF
Zone 2 OFF OFF ON
Zone 3 OFF ON OFF
Zone 4 OFF ON ON
Zone 5 ON OFF OFF
Zone 6 ON OFF ON
E
1 2 3
Open the sensor, take out the battery
connector, and place the battery! Check the
house code; same as PIR and Remote Dip 1-
8 from 1-12. Select the Zone you want: setting
Dip 9-11 according the overview at the PIR.
Mark the Zone number on the magnet.
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Elro AP5500 - Pro Alarm System wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Elro AP5500 - Pro Alarm System

Elro AP5500 - Pro Alarm System Kurzanleitung - Deutsch - 10 seiten

Elro AP5500 - Pro Alarm System Bedienungsanleitung - Englisch - 49 seiten

Elro AP5500 - Pro Alarm System Kurzanleitung - Holländisch - 8 seiten

Elro AP5500 - Pro Alarm System Bedienungsanleitung - Holländisch - 42 seiten

Elro AP5500 - Pro Alarm System Kurzanleitung - Französisch - 9 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info