Operating instructions
RDJ10
RF/SET
The RDJ10RF/SET consists of a RDJ10RF wireless temperature controller and a RCR10/433 receiver. The RDJ10RF allows
you to set the desired room temperature (setpoint) at the time you want. The unit features an ergonomic setting knob for ease of
temperature control.
Display
Actual room temperature in ºC
Indicates when there is demand for
heat
The unit is controlling to the selected
comfort temperature
Replace batteries
The unit is controlling to the selected
energy saving temperature
Frost protection: The unit is
controlling continuously to the frost
protection temperature at 5°C
The unit is controlling to the frost
protection temperature at 5 ºC
Energy saving mode: The unit is
controlling continuously to the
energy saving temperature
Indicates when the temperature
setpoint has been changed by the
user. This setpoint will be maintained
until the next switching time. This
function is only active when the unit is
in automatic mode.
Comfort mode: The unit is
controlling continuously to the
comfort temperature
Automatic mode: The unit is
controlling to the selected time and
temperature programs.
Setting knob
Warmer / colder for selecting
the temperature
Programming selector
Battery compartment
2 alkaline batteries type AA, 1.5 V
Time setting position
Operating mode selector
This silder determines how the thermostat
operates
A1
First switch on time
Automatic mode: In this position the thermostat switches at
the programmed times and temperatures
A2
First switch off time
In this position the thermostat ignores all programmed times
and runs permanently at the temperature set in
A3
Second switch on time
In this position the thermostat ignores all programmed times
And runs permanently at the temperature set in
A4
Second switch off time
Frost protection Thermostat runs permanently at 5°c
Comfort (ON) temperature setting
Advance button
Energy saving (OFF) temperature
setting
Switches the operating mode from comfort to energy saving,
or vice versa, until the next switching time
RUN
Set the controller to RUN when all
programming is completed
Introduction
This leaflet provides you easy-to-follow instructions on how to set-
up your RDJ10RF programmable room thermostat.
Contents
Commissioning
Initial power up
How do I set the Clock
How do I set the ON and OFF times
How do I set the comfort (ON) temperature
How do I set the energy saving (OFF) temperature
How do I Change batteries
Configuration instructions for the Siemens RCR10RF/SET
(Wireless RF version only)
Energy savings tips
Commission
Remove the black transit tabs from the
alkaline batteries.
Check to see if the battery holder is in the
correct position.
If no batteries are inserted, fit 2 alkaline
batteries type AA in the battery compartment.
Initial power-up
Once batteries are fitted all symbols will be
displayed on the display screen as shown for
around 2 seconds.
Set Clock
1. Move the vertical slider to position
2. The current time setting flashes.
3. Turn the setting knob counterclockwise -
to decrease the time, or clockwise +
to increase the time.
4. When the correct time is displayed move
the programming vertical l slider to any other
position to confirm your setting.
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Siemens RDJ10RF wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Siemens RDJ10RF

Siemens RDJ10RF Bedienungsanleitung - Deutsch - 2 seiten

Siemens RDJ10RF Bedienungsanleitung - Französisch - 2 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info