• When connecting the PW-630MA to a computer Ensure that the computer conforms to IEC60950.
•Please make sure you place the Platform on a level and stable surface. If the equipment is used when the Platform is
unstable because not all feet are on the surface, there may be a risk of stumbling or inaccurate measurement.
Never jump on the Platform, there may be a risk of stumbling and malfunction of the equipment.
• When handling printer unit, avoid any sharp edges.
For the PW-630MA; Ensure you use the original AC Adapter (MODEL: SA25-0535U). Using an AC Adapter other than the
original one may cause malfunction.
Do not insert or remove the plug by the cable.
This equipment incorporates a fuse for electrical equipment (2A, 125V). If an AC Adapter other than the original one is
used or there is a large surge in electric current, the fuse will blow for safety purposes. If the fuse has blown, the equipment
must be inspected again. The fuse is located inside the equipment and users cannot disassemble the equipment easily.
Therefore, please contact your nearest Tanita branch office or dealer to change the fuse.
• Do not jump on the scale.
Do not step on the rail.
• Do not place a finger into the gap or hole of this equipment.
You may get injured.
Before use
(cautions for safety)
4
Safety Notes
Before use
(cautions for safety)
5
Do not lean the product against the wall where people and objects pass by.
Someone may touch the product and it may fall down.
Caution Symbols
Thank you for purchasing this precision crafted Tanita product. For optimum performance and safety, please
familiarize yourself with the Caution Symbols below. These symbols are designed to alert the user to potential
hazards when using this equipment. Ignoring these Caution Symbols may result in serious injury, or damage to
the product.
Please be sure to review before proceeding with the INSTRUCTION MANUAL.
Inserting and Removing the Power Cord
To reduce the risk of electric shock or product damage, never insert or remove the power cord with wet
hands.
Do not under any circumstances dismantle or alter the device, as this could result in electric shock or
injury as well as adversely affect the precision of measurements.
To prevent fire hazard
Use only a correctly wired (100 - 240V AC) outlet, and do not use a multiple outlet extension cable.
Measurements for physically disabled persons
Physically disabled persons should not attempt to take measurements alone, but instead should have
their caretakers assist them in using the device.
This symbol indicates the possibility of serious injury if the product is
mishandled or instructions are ignored.
This symbol indicates the possibility of physical injury or equipment
damage if instructions are ignored.
This symbol indicates general precautions that should be taken when
using this product.
This is a precision manufactured and accurately calibrated product. Please observe the following
instructions.
Users must not disassemble or adjust this equipment. This should be done by trained maintenance agents or certification
offices designated under the NAWI directive.
Never disassemble or adjust the equipment, as this may cause malfunctions. The equipment should only be inspected in
accordance with the regulations in each country.
• When not in use for a long time, unplug the AC Adapter from the wall socket.
•Donot wipe the equipment with corrosive chemicals (benzine, cleaner, etc.). Please use a neutral detergent to clean the
equipment.
• Avoid subjecting the equipment to excessive shocks or vibrations.
• When disposing of this unit, please do so in accordance with the prevailing regulations in each country.
If an unauthorised person attempts to disassemble or repair any of the part, the warranty will become invalid. When the
unit malfunctions, please consult your nearest Tanita sales office or agent.
Please observe the following instructions for accurate measurement.
Measurement may not be possible on a surface that is strongly vibrating. In such cases transfer the equipment to a stable
surface with little or no vibration.
In the case to move to a place with a temperature difference of 20˚C or more, leave it before use for 2 hours or more after
moving.
While taking measurements, please keep any persons using transmitters, such as a mobile phone, away from the unit to
avoid causing margin errors.
<Usage Conditions>
Temperature Range for Use : 0˚C - 35˚C
Relative Humidity : 30% - 80% (without condensation)
<Storage Conditions>
Temperature Range of Environment : -10˚C - 60˚C
Range of Relative Humidity : 10% - 90% (without condensation)
To avoid malfunctions, avoid storing the equipment where there is direct sunlight, significant temperature
changes, the risk of dampness, a large amount of dust, in the vicinity of fires, or where there is the risk of
receiving vibrations or shocks.
<Power Source>
Model Name
PW-630MA
Voltage Range
100 - 240VAC
Frequency Range
50 / 60 Hz
Electric Current Range
550 mA
3

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Tanita PW-630MA wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info