581306
1
Zoom out
Zoom in
Vorherige Seite
1/2
Nächste Seite
Button Placement
RESET - resets programs and clock to
factory settings
SET CLOCK
ECONO
PROGRAM
UP/DOWN
AHEAD/BACK
HOLD
USAGE
- activates ECONO mode programs
- scrolls through program
settings
- sets program temperatures
- sets program times
- disables all programs and keeps
temperature constant
- displays the accumulated system
“ON” time
OPERATION
LCD Display
Press the button to activate or de-activate the ECONO
mode programs. The “ECONO” symbol will appear on the screen
when the ECONO mode is activated.
ECONO
2
Press the button again to
view USAGE THIS WEEK.
USAGE
1
Press the button once to
view USAGE TODAY.
USAGE
*
- USAGE TODAY automatically resets itself daily at midnight.
- USAGE THIS WEEK automatically resets itself at the end of the week
at 00:00:00.
- A new week begins Monday morning.
Days Of The Week
Clock Display; Usage Display
Usage Monitor Function
Temperature Units (
Current Temperature
Heat “ON” Indicator
Program Number
Set Temperature
Power Failure Indicator
HOLD Function
ECONO Mode
Cor° °F)
Programmable Thermostat
HTM311A
DISPLAY / BUTTONS
2
ECONO MODE
OWNER’S
MANUAL
Read and understand this
manual before installation or
use.
FEATURES
!
!
!
!
!
!
!
!
!
!
Ideal for electric baseboards,
convectors and radiant ceiling
heaters
5+1+1 day programming
ECONO mode
12/24 hour clock
Temperature display (
Usage Monitor - keeps track
of accumulated “ON” time
Simple 2-wire installation
Rating: 240V AC, 60Hz
MAXIMUM LOAD: 15A
- 3600W @ 240V
MINIMUM LOAD: 750W
°C or °F)
4
6
11
C
F
C
F
P2
P3 P4
P1
MO TU WE TH FR SA SU
AM
PM
USAGE TODAY THIS WEEK
HOLD ECONO
*
4
1
2
357
6
1
2
3
4
5
6
7
8
8
1
2
3
4
5
6
7
8
9
10
11
2
3
Press the or button to
toggle the time forward or back.
AHEAD BACK
Press the button to start setting.PROGRAM
1
Press the button to enter the ECONO mode.ECONO
4
Press the or button to
toggle the SET temperature up or down.
UP DOWN
5
Press the button for day setting.
The day will be blinking.
SET CLOCK
6
Press the or button to
select the day.
AHEAD BACK
7
Press the button to
advance to the next program setting
and repeat steps .
PROGRAM
36
C
C
P1
MO
AM
*
CAUTION!
Maximum load for this thermostat is 15A, 3600W resistive. DO NOT
exceed this limit; otherwise a potential fire hazard exists.
TO AVOID FIRE, SHOCK, OR DEATH, SHUT OFF POWER SUPPLY AT
THE CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS
OFF BEFORE WIRING.
This product operates at 208/240V AC. Do not install it unless you are
completely familiar and competent with house wiring. Handle with
caution to prevent any risk of electrical shock that could cause serious
injury or death.
For wiring, use COPPER conductors only.
All wiring must comply with applicable codes and regulations.
DO NOT connect voltage different from device rating. This thermostat
will not operate at 120V AC.
Ensure that the heating system is protected by appropriate circuit
breakers or fuses.
INSTALLATION
2
3Mount the new thermostat into
the wall box using the two
screws provided through the
mounting holes. (Remove the
cover if necessary).
Using the wire nuts provided,
securely fasten each wire from
the new thermostat to a wire in
the wall box. Refer to the
diagram. NOTE: ENSURE NO
BARE WIRE IS EXPOSED.
1Remove the old thermostat
carefully and identify the two
wires from the wall box.
4Reconnect power supply.
DISCONNECT THE POWER SUPPLY AT THE CIRCUIT BREAKER OR
FUSE BEFORE PROCEEDING WITH THE INSTALLATION.
*
SETTING THE TEMPERATURE DISPLAY ( C F)or
You will now have 16 seconds to set the temperature display to C or F by
pressing the or button. (Factory Default = C).UP DOWN If necessary,
the button may be pressed after 16 seconds to start over.RESET
°°
°°
°
*
Wire Nut
2-Wire Installation:
Wall Box
4-Wire Installation:
Wire Nut
Wall Box
208/240V AC
Line
Electric
Baseboard
Heater
Electric
Baseboard
Heater
208/240V AC
Line 9
10
1
5
78
3
The ECONO mode consists of 2 program settings. You can basically use this
function for an installation at a cottage/vacation home. The 2 program settings
run on a weekly basis. One setting is used to raise the temperature to a
comfortable level while you are there at the cottage, and the second setting is to
bring the temperature back down for energy savings while the cottage is vacant
during the rest of the week.
FOR EXAMPLE:
If you go to your cottage only during the weekends, then you can set the ECONO
programs as such:
P1-SATURDAY-8:30amfor21C;and,
P2-SUNDAY-5:00pmfor15C
This means the cottage will be heated at 21 C between Saturday morning at
8:30 am to Sunday evening at 5:00pm. For the rest of the week from Sunday
evening at 5:00 pm to the next Saturday morning at 8:30 am, the cottage will be
kept at a low temperature level of 15 C for energy savings.
°
°
°
°
By default the ECONO mode is pre-programmed as follows:
P TIME
P1
P2
3:00 pm
10:00 pm
15.0 C (59.0 F)
oo
16.0 C (61.0 F)
oo
FRIDAY
ECONO MODE
To set the ECONO mode programs, follow the steps below:
OPERATION
CURRENT TEMPERATURE DISPLAY
The current (room) temperature is displayed
in the center panel of the LCD screen.
HEAT “ON” INDICATOR
The thermostat displays the symbol when
the heating system is ON and turns it off when
the heating system is OFF.
TEMPORARY OVERRIDE
To change the temperature temporarily,
press the or button to set the desired temperature. The thermostat
will return to the regular program at the next scheduled program time.
UP DOWN
HOLD FUNCTION
This feature is used to hold the thermostat at a constant temperature and
disable all set programs until released.
- Press the button once and use the or button to set the
desired hold temperature. The “HOLD” symbol will appear on the screen
to indicate that the HOLD function is active.
HOLD UP DOWN
- To cancel the HOLD function, press the button again. The “HOLD”
symbol will disappear and the thermostat will return to the programmed
temperature.
HOLD
C
C
P1
FR
PM
ECONO
PROGRAMMING
FOR FRIDAY
PROGRAM
TIME
SET
TEMPERATURE
PROGRAM
NUMBER
ECONO
USAGE MONITOR
This thermostat tracks the system “ON” time, or
the time the heating equipment is running.
C
C
P1
USAGE TODAY
USAGE
DISPLAY
USAGE
MONITOR
FUNCTION
HEAT “ON”
INDICATOR
CURRENT
TEMPERATURE
SET
TEMPERATURE
HOLD
C
C
MO
AM
HOLD
MEMORY BACKUP / POWER FAILURE INDICATOR
This thermostat is equipped with a built-in rechargeable
battery. The internal battery serves to protect the time
and program settings in the case of a power failure.
Under normal conditions the memory will be retained
for several days if the power goes out for that long.
In the event of a power failure, the symbol will
appear on the screen and the time will continue to run.
MO
AM
POWER
FAILURE
INDICATOR
TIME
PAGE 1 PAGE 2 PAGE 3 PAGE 4
PAGE 8 PAGE 9 PAGE 10 PAGE 11
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für UPM HTM311A wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von UPM HTM311A

UPM HTM311A Bedienungsanleitung - Französisch - 2 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info