Using PFL / AFL Allen & Heath are renowned for bringing you
the most comprehensive engineer’s monitoring system in consoles at
this price point. We recognise the importance of correct gain structure
and signal handling. The GL2400 includes LED meters for every
input channel and main output, as well as a pair of high resolution
meters dedicated to monitor duty only. In monitor mode the M fader
and associated controls become a full featured PFL/AFL monitor feed
for the engineer’s listen wedge.
The input channels provide PFL (pre-fade listen) so that each source
can be checked using the meters and headphones before you bring
the fader up. You can even use PFL while the channel is muted to
prevent the signal reaching the house and monitor speakers until you
have checked it and are ready.
All the main, aux and matrix outputs provide AFL (after-fade listen) so
that you can check the exact level leaving the console. Once again,
the AFL switch gets its source before the output mute switch so that
you can check the signal before you send it to its destination. This
can be very important when you are feeding remote destinations such
as broadcast and recording.
The Decibel the ‘Bell’ is the unit of sound level. Decibel is 1/10
Bell, a more conveniently sized unit. dB = 20 log (Vo / Vi) where Vi
and Vo are two signal voltages, in and out (ignoring the impedances).
The dB is used to express the relationship between two levels, chosen
because of the logarithmic way our ears respond to sound. The ‘dB’
relates one level to another. For example, a preamp with a gain of
40dB (100x) would produce an output of +10dBu for an input of -
30dBu. Several audio standards exist to relate a signal level to a
known reference. Audio engineers need to deal with a variety of
equipment standards, for example, a -10dBV CD player plugged into a
console with +4dBu outputs connected to a 0dBu input DSP speaker
manager, or an operator using an SPL (sound pressure level) meter to
measure sound intensity.
dBu Relative to 0.775Vrms – professional standard
0dBu = 0.775V +4dBu = 1.228V
dBV Relative to 1Vrms - consumer audio standard
0dBV = 1V -10dBV = 316mV = -8dBu
dB-A Sound pressure with a filter contour to approximate
the response of the human ear. Three curves A, B,
C exist for different loudness.
dBfs Relative to signal maximum before clip (full scale)
Using Inserts The GL2400 channel inserts operate at 0dBu,
the output inserts operate at -2dBu. In practice this makes little
difference as long as the inserted equipment is intended for line level
operation (-6 to +4dBu). Simply set the gain through the device to
unity (0dB) with the bypass switch pressed (if available). With the
effect switched in, use the console channel gain control to make any
further adjustments needed. This keeps the gain structure correct
through the channel signal path.
With nothing plugged into the insert, the channel signal is routed
through a switching (‘normalling’) contact in the socket. As soon as a
jack is plugged into the socket the contact is opened and the signal
path broken so that the external device can be patched in series with
the signal.
AFL
dB
SEND
INSERT
RETURN
TIP
RING
If you suspect the insert
socket to be faulty or
intermittent through excessive
wear or contamination, test for
this by plugging in a jack with
its tip shorted to its ring
contact. This bypasses the
contact in the socket. Clean
using suitable electrical
contact cleaner.
Tech talk…
For an audio circuit stage:
Pi = Input signal power
Po = Output signal power
The Decibel is defined as:
dB = 10 log (Po / Pi)
= 10 log (Vo
2
/Ro / Vi
2
/Ri)
If input and output impedances
Ri and R0 are the same, then:
dB = 20 log (Vo / Vi)
dBm is defined as 1mW into
600 ohms = 0.775V
dBu = 0.775V ignoring the
600 ohms as we assume high
input and low output
impedance and therefore
maximum voltage transfer
between stages, appropriate
for modern audio.
25

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Allen-Heath GL 2400 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info