SPECIFICATIONS
Input voltage ........................................................................... 9.5 to 16 VDC
Current
Typical ..................................................................................... 15 mA
Maximum ................................................................................. 25 mA
Electrical configuration ....................................................................... Form C
Relay rating ....................................................................... 16 V, 50 mA max.
Tamper switch rating ....................................................... 12 V, 50 mA max.
Detection range ............................................................ 0.9 m - 7.6 m x 360°
Alarm response ................................................................................... 4 sec.
Minimum glass size ............................................................. 30.5 cm x 61 cm
Recommended glass thickness:
Plate ........................................................................ 2.5 mm - 6.5 mm
Tempered .................................................................. 3 mm 6.5 mm
Wired ...................................................................................... 6.5 mm
Laminated .............................................................................. 6.5 mm
Operating temperature ....................................................................0° - 50°C
Relative humidity .................................................. 10 - 90% non-condensing
Round housing dimensions: ............................................. 2 x 10 cm (D x Æ)
Rectangle housing dimensions: ....................... 11.5 x 7 x 2 cm (H x W x D)
Color ................................................................................................. White
Field wiring size ......................................................................... 18-24 AWG
SETTING THE R ANGE
The detector has a spring clip (J3) to set room size. See Figure 4. Use the
following table to determine what setting to use for an application.
Setting Description
Open Sets the range for 1.5 m to 7.6 m. Use for rooms
30 m² and larger. Default
Closed Sets the range 1 m to 3 m. Use for rooms smaller
than 30 m².
TESTING THE D ETECTOR
Use a Sentrol 5709C hand-held tester to verify detector range and operation.
To test the detector:
1. Set the tester to the appropriate glass-type setting. Use the tempered
setting if you are unsure about the glass type.
2. Put the detector in test mode as follows:
- Hold the tester close to the detector. See Figure 5.
- Activate the tester.
The LED on the detector lights for 4 seconds and then starts flashing to
indicate the detector is in test mode. The relay opens for 4 seconds, then
returns to standby.
3. Hold the tester near the surface of the glass to be protected and aim the
speaker at the detector. Be sure the tester is at the point on the glass
farthest from the detector. If closed curtains are present, hold the tester
behind them. See Figure 6.
4. Press the test button on the tester. The LED on the detector should stay
on for 4 seconds to indicate the glass is within detection range of the
detector. If the LED does not stay on for 4 seconds, move the detector
and retest.
UNDERSTANDING THE LED
The red LED located on the front of the detector indicates the status of the
unit as follows:
Status LED indication
Power on Flashes when power is applied.
Clap test/Alarm
memory In response to the clap test:
Flashes twice to indicate the detector has power
and is functioning properly.
Or
On for 4 seconds to indicate the detector has
alarmed.
Alarm On for 4 seconds with relay when breaking glass
is detected.
Test mode On for 4 seconds with relay, then flashes for 60
seconds. Each test trigger resets the test mode
clock and the LED restarts flashing for 60
seconds.
USING THE H AND-CLAP T EST AND A LARM M EMORY
Check the alarm memory and detector operation with the hand-clap test as
follows:
1. Standing under the detector, clap your hands together.
2. Observe the LED on the detector.
If the detector has power and is functioning properly, the LED quickly
flashes twice.
If the detector has alarmed, the LED will light for 4 seconds. Cycle the
power to clear the alarm memory.
The hand-clap test is intended as a functional test and is not an accurate
indication of detector range.
J3 Spring clip
Figure 4 - Detector Knockout Locations
Figure 5 Using the Tester
Figure 6 - Testing the Range
• Single
• Continuous
Plate •
Tempered •
Laminated •
Battery LED
Battery is OK if LED
stays on during test
5709C
Shatter Series Tester
Use for testing:
ShatterPro
Shatterbox
Shatterbox II
ShatterSwitch
SENTROL
2.5 cm
Knockouts
Knockouts
Slot
J3
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Aritech SHATTERPRO 3 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info