The display is divided into three parts in order to show several parameters simultaneously. The
selection of the parameters for the individual display areas is done with the keys 3, 2 and 9. The
grid symbols on the keys indicate the display area.
Each time you press an individual key, the display is switched to the next parameter.
Key 3 switches the display area on the left top,
Key 2 switches the display area on the right top,
Key 9 shifts the display area on the bottom.
Presetting the tariff and alarm limit for the current and rated power
Some of the parameters in the display on the top right and on the bottom can be set individual-
ly. However, the parameters can only be set one after the other. Make sure only the appropri-
ate parameter is selected in the display. The setting will be completed, if no button is pushed for
about 10 seconds.
The measuring instrument has options for individually setting the electricity tariffs (cost/kWh) and
alarm limits for the max. current (A) or the max. electrical power. When the set current or power
values are exceeded a signal is emitted.
Setting the electricity tariff „wcost/kWh“:
Press the key „F“ (2) repeatedly, until „W“ appears in the upper right display.
Press the key „
“ (9) repeatedly, until the display shows „COST/kWh v“.
The „SET“ key (8) activates the settings menu. The first digit flashes. If you press the key again,
the decimal place will change.
With the keys „S“ (3) and „F“ (2), the value can be changed.
To complete the setting, press the key „
“ (9) or wait for approx. 10s. The setting is completed.
Setting the alarm limit for max. current and max. rated power:
Press the key „
“ (9) repeatedly, until the lower display shows „TOTAL kWh“.
Press the key „F“ (2) repeatedly, until the display shows „OVERLOAD“.
The „SET“ key (8) activates the settings menu. The last set unit (W or A) flashes.
With the keys „S“ (3) and „F“ (2) the unit can be changed.
„W“ corresponds to the effective power in Watt
„A“ corresponds to the current in ampere.
The „SET“ key (8) confirms the selection and switches to the next digit input. The first digit flash-
es. If you press the key again, the decimal place will change.
With the keys „S“ (3) and „F“ (2), the value can be changed.
To complete the setting, press the key „
“ (9) or wait for approx. 10s. The setting is completed.
Operation
If the product is overloaded, it may be damaged . The warranty/guarantee will
become void in these cases.
Do not plug together several energy cost measuring instruments.
The device is not approved for use in areas where there is a risk of explosions.
Avoid areas with strong magnetic fields (motors etc.).
Avoid blows or strong vibrations, as well as the use in direct sunlight.
Plug the energy cost measuring instrument into a domestic wall socket with earth protection and
230 V AC voltage.
Make sure that the electric device you wish to measure is switched off. Connect the mains plug
of the electrical device to the earthed socket (1).
Switch on the electric device and wait a few seconds until the measuring instrument shows the
first measured data.
The following displays can be switched between using the control keys:
Display on the top right
The key „S“ (3) switches the functions in the upper left display. Every time you press the key,
you switch the display.
Mains voltage, mains frequency, power factor, mains voltage ...
230 3680
6.20
V W
TOTAL kWh
50 3680
6.20
W
TOTAL kWh
Hz
0.98
3680
6.20
W
TOTAL kWh
POWER
FACTOR
Display on top right
The key „F“ (2) switches the functions for the upper right display. Every time you press the key,
you switch the display.
Effective power, max. measured power, alarm limit (W or A), cost forecast (to switch between
day/month/year use the „SET“ key), current consumption, max. measured current consumption,
effective power ...
The MAX values can be cleared in the relevant display by pressing the „SET“ key (8) for approx.
3s. A short beep confirms the deletion process.
Display on the bottom
The key „
“ (9) switches the functions of the lower display. Every time you press the key, you
switch the display.
Electrical work (total power consumption), electricity tariff, total electricity costs, total operating
time, electrical work (total power consumption) ...
The total operating time can be deleted in the displayed function "TOTAL TIME". To do this, set
the display on the top right (6) to "A" and press the key "SET" (8) and hold it for approx.
3 seconds. A short beep will confirm the deletion process.
Maintenance and Cleaning
For cleaning, always unplug the device. Clean the device with a dry, anti-static cleaning cloth
without any chemical cleaning agent.
Electronic products are raw material and do not belong in the household waste.
When the device has reached the end of its service life, please dispose of it, accord-
ing to the current statutory requirements, at your local collecting site. Disposal in the
domestic waste is not permitted!
Disposal of used batteries!
As a consumer you are required (Battery Ordinance) to responsibly dispose of all used batter-
ies and rechargeable batteries; it is forbidden to throw them away with the normal house-
hold waste!
Contaminated batteries/rechargeable batteries are labelled with these symbols to
indicate that disposal in the domestic waste is forbidden. The symbols for the rele-
vant heavy metals are: Cd = Cadmium, Hg = Mercury, Pb = Lead. You can
dispose of your used batteries/rechargeable batteries free of charge at your com-
munity’s collection point or any place where batteries/rechargeable batteries are
sold! You thus fulfil the legal requirements and make your contribution to pro-
tecting the environment!
Technical Data
Parameter Value Accuracy
(for 23°C (+/- 5°C))
Operating voltage 230 V/AC 50 Hz
Power consumption <1 W
Max. power/current 3680 W/16A
Measuring range for voltage (V) 190 – 276 V +/-3%
Measuring range for current (A) 0.005 – 16.00 A +/-(3% + 0.01 A)
Measuring range for effective power (W) 1 – 3680 W +/-(3% + 2 W)
Measuring range for frequency (Hz) 45 – 65 Hz +/-2 Hz
Measuring range kWh 0.00 – 9999.99 kWh +/-(5% + 0.1 kWh)
Measuring range for power factor 0,70 – 1,00 +/- 0.1 (for >1A, sine,
50 – 60 Hz)
Button cell batteries 2 x LR44
Dimensions (HxWxD) in mm 130 x 63 x 80
Weight approx. 160 g
Ambient conditions 5 - 40 °C/max. 90%rH (not condensing)
Operating altitude: max. 2000 m (above MSL)
230 3680
6.20
VW
TOTAL kWh
230 3680
0.024
VW
TOTAL kWh COST/kWh
230 3680
02:05:34
VW
TOTAL kWh TIME
230 3680
VW
TOTAL kWh
0. 5
230 25
6.20
V W
TOTAL kWh
230 48
6.20
V W
TOTAL kWh
MAX
230 3000
6.20
V W
TOTAL kWh
OVERLOAD
230 0.50
6.20
V
TOTAL kWh
FORECAST
DAY
230 0. 06
6.20
V
TOTAL kWh
A
230
0.208
6.20
V
TOTAL kWh
MAX
A
These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data pro-
cessing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in technology and equipment reserved.
© Copyright 2009 by Conrad Electronic SE.
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

basetech-cost-control-3000

Suche zurücksetzen

  • das Basetech control 3000 ist sehr schwirig zu Bedinnen .
    Schon die Zeichen auf dem Gerät sind nicht geradwe selbsterklärend
    Vor allem bin ich bisher noch nicht darauf gekommen wie ich alle Werte wieder auf Nullstell.Dies finde ich eine wichtige funktion um ein neues Gerät zu messen. Eingereicht am 21-4-2020 13:21

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Basetech COST CONTROL 3000 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info