By briey pressing the “SET” button, the display in the middle and bottom display line can be
switched between the combinations:
- Mains voltage (V) + energy costs (COST)
- Current (A) + (COST/kWh)
- Mains frequency (Hz) + operating time (DAY)
- Power factor (POWER FACTOR) + CO
2
emission (kgCO
2
)
- Power limit for overload indication (W, OVERLOAD)
- Load power consumption (W) + Energy costs (COST)
Simultaneously briey press the “SET” and “ENERGY” buttons to reset the stored time period
for the load operating time.
Simultaneously press the “SET” and “COST” buttons to reset the energy costs (COST).
To reset the energy cost meter and all settings to the default settings, briey press the sunken
“RESET” key, e.g., with a pen. All display segments will briey appear on the display; there-
after, the energy cost meter will once again be operational. All measured data are deleted, all
settings (electricity price, overload limit) are reset.
A reset should also be carried out if only confusing signs appear on the display or
the keys do not work.
Maintenance and cleaning
The product is maintenance-free for you. Maintenance or repair work may be performed only
by qualied personnel or a specialised repair shop. There are no self-serviceable compo-
nents inside the product, that is why you should never open it (apart from inserting/replacing
the batteries, as described in these operating instructions).
Prior to cleaning the measuring device, completely remove it from the mains socket. Remove
the connected load from the socket of the measuring device.
To clean the outside of the product, a dry, soft and clean cloth is sufcient.
Dust can easily be removed using a clean, long-haired brush and a vacuum cleaner.
Never use abrasive cleaning agents, rubbing alcohol or other chemical solutions, since these
could damage the casing or even impair operation.
Disposal
a) Product
Electronic devices are recyclable and do not belong in the household waste. Dispo-
se of an unserviceable device in accordance with the relevant statutory regulations.
Remove any inserted batteries and dispose of them separately from the product.
b) Batteries and rechargeable batteries
As an end user, you are required by law (battery ordinance) to return all used batteries and
rechargeable batteries; it is not permitted to dispose of batteries with normal household waste.
Batteries/rechargeable batteries containing hazardous substances are labelled with
these symbols to indicate that their disposal in household waste is forbidden. The
designations for the heavy metals involved are: Cd = cadmium, Hg = mercury, Pb =
lead.
Used batteries, rechargeable batteries and coin cells can be returned to collection points in
your municipality, our stores or wherever batteries/rechargeable batteries/coin cells are sold.
That way you full your statutory obligations and contribute to the protection of the environment!
Technical data
Operating voltage ......................... 230 V/AC, 50 Hz
Own power consumption .............. approx. 1 W
Max. connection power ................. 3680 W (230 V/AC, 16 A)
Electricity tariff resolution .............. 0.01
Battery type .................................. 2x LR44
The batteries are used to retain data if the energy cost meter is not plugged into a
wall socket.
Operating conditions .................... 0 °C to +50 °C, 20% to 90% relative humidity,
noncondensing
Storage conditions ....................... 0 °C to +50 °C, 10% to 90% relative humidity,
noncondensing
Dimensions (H x W x D) ............... 150 x 76 x 78 mm
Weight .......................................... approx. 200 g
Voltage:
Measurement range ..................... 200 - 276 V/AC
Tolerance ...................................... ±1.5%
Resolution .................................... 0.1V
Frequency:
Measurement range ..................... 45 - 65 Hz
Current:
Measurement range ..................... 0.005 - 16 A
Tolerance ...................................... ±2%
Resolution ..................................... 0.001 A @ 0 - 9.999 A
...................................................... 0.01 A @ 10 - 16 A
Power:
Measurement range ..................... 0.3 - 3680 W
Tolerance ...................................... ±2% + 2 W
Resolution ..................................... 0.1 W @ 0 - 999.9 W
...................................................... 1 W @ 1000 - 3680 W
Power factor:
Measuring range ........................... 0.00 - 1.00
Resolution ..................................... 0.01
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

basetech-em-3000

Suche zurücksetzen

  • guten abend,
    wo wird mir denn angezeigt, wieviel KW bisher verbraucht worden sind, damit ich zb. einen Tagesverbrauch habe? mfG Eingereicht am 13-10-2021 17:06

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Basetech EM-3000 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info