2. Preconditions for installation
The appliance can only be sold in the countries mentioned
in the type plate.
2.1 Regulations
Gas safety (installation & use) Regulations 1998.
It is the law in GB that a competent Person in accordance
with the above regulations installs all gas appliances.
Failure to install appliances correctly could lead to
prosecution.
It is in your interest , and that of safety, to ensure compliance
with the law.
Caravan & holiday homes:
the installation must meet the following standards Bs 5482:2
LPG and EN721 ventilation.
2.2 Location
The appliance should be sited in a well ventilated room where
it will not be exposed to temperatures below freezing.
To prevent corrosion, the combustion air must not contain
any corrosive substances. Substances classed as corrosion-
promoting include halogenated hydrocarbons such as are
found in solvents, paints, adhesives, aerosol propellants and
various household cleaners. Appropriate measures should
be taken where necessary.
With the exception of the flue pipe, the surface temperature
of the appliance is below 85 °C. No special safety measures
are therefore necessary.
Site appliance as shown in Fig. 5.
Always site appliance in a location not exposed to
temperatures below freezing. If this is not possible, the
appliance must be switched off and drained and the batteries
removed whenever there is a risk of freezing.
Do not install the appliance in rooms where the free volume
is less than 8 m
3
.
Air admission
The room where the appliance is to be installed should be
provided of fresh air inlet areas according with the below
table.
Minimum requirements are listed above. Local regulations
should allways be observed.
2.3 Fixing the appliance
Remove the temperature control and the output control.
Remove the outer case by sliding it forwards and then lifting
upwards.
Fix the appliance using the sleeves and hooks supplied so
that it is vertical.
Never allow the appliance to rest against water or gas
pipes.
2.4 Water connection
It is advisable to drain the appliance before installing it as
any dirt or grit inside it could reduce the water flow rate and,
To prevent problems caused by sudden pressure fluctuations
in the water supply, it is advisable to fit a non-return valve
to the water outlet.
2.5 Gas connection
Take care to ensure dirt is not allowed to enter gas inlet.
Make sure that the type of gas specified on the appliance
type plate is the same as that supplied by the gas authorities.
Select pipe diameter to suit output of instantaneous water
heater being installed.
Fit gas service cock as close to appliance as possible.
Fig. 4 Water connection
in extreme cases, could completely clog up the appliance.
Mark hot water (fig.4, pos.B) and cold water pipes (fig.4,
pos.A) so as to prevent confusion.
Connect pipe to automatic water valve using the connecting
kit supplied.
Appliance Minimum area
WR 8
WR 11
60 cm
2
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch WR8..P... wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info