SOUND
Your new Evolution V air conditioner is different from most
cooling systems. Because this is a variable speed system, it is
designed to operate at different speeds depending on the
temperature and humidity conditions. You may notice the sound
coming from the outdoor unit changing from time to time
depending on the weather conditions. The higher speed produces a
higher sound. This change of speed allows the system to operate
more efficiently and maintain comfortable conditions inside the
home as the outdoor temperature rises. You may also hear a slight
hissing sound when near the outdoor unit in the off--cycle. This is
the sound of system pressure equalization which is required to
enable soft and easy starting of the next cycle. These sounds are
normal and do not represent a problem with your system.
ROUTINE MAINTENANCE
Simple, routine maintenance as described below will enhance your
air conditioner systems ability to operate economically and
dependably . Always remember the following safety precautions:
!
WARNING
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal
injury or death.
Before installing, modifying, or servicing system, main
electrical disconnect switch must be in the OFF position.
There may be more than 1 disconnect switch. Lock out and
tag switch with a suitable warning label.
NOTE: There may be more than one electrical disconnect switch.
A07903
Main
Disconnect
Indoor
Disconnect
Outdoor
Disconnect
Thermostat
Fig. 1 -- Electrical Disconnects
CUT HAZARD
Failure to follow this caution may result in personal injury.
Although special care has been taken to minimize sharp edges
in the construction of your unit, be extremely careful and wear
appropriate protective clothing and gloves when handling
parts or reaching into the unit.
CAUTION
!
S Keep Filter Clean
A clogged or improperly installed air filter on your indoor unit will
increase operating costs and shorten the life of the unit. For
detailed filter cleaning information refer to indoor unit literature.
S Do Not Block Floor, Wall or Ceiling Vents
When drapes, furniture, toys or other common household items
block vents, the restricted airflow lessens the system’s efficiency
and life span.
S Do Not Cover or Block Outdoor Unit
The outdoor unit needs unrestricted airflow. Do not cover it or
place items on or next to it. Do not allow grass clippings, leaves, or
other debris to accumulate on the sides or top of the unit. And,
maintain a 12” (304.8 mm) minimum clearance between the
outdoor unit and tall grass, vines, shrubs, etc.
S Check Condensate Drain
Your air conditioner removes humidity from your home during the
cooling season. After a few minutes of operation, water should
trickle from the condensate drain of the indoor coil. Check this
occasionally to be sure the drain system is not clogged. Drainage
will be limited if you live in a very dry environment.
S Do Not Operate Below Minimum Operating Temperatures
in Cooling Mode
Your outdoor unit is not designed to operate below the minimum
temperatures shown below. The minimum temperature depends on
which wall control is being used:
With Evolutionr Connext Control: 40_F(4.4_C)
W ith Thermostat Control: 55_F (12.8_C)
System protections may not allow the unit to operate below these
minimum temperatures.
S Base Pan Drainage
Periodically check for and remove debris that has settled around
the base of your outdoor unit. This will ensure proper drainage of
the base pan and eliminate standing water inside the outdoor unit.
S Level Installation
Your Bryant dealer will install the outdoor unit in a level position.
If the support base settles or shifts and the unit is no longer level,
be sure to re--level it promptly to assure proper drainage. If you
notice water or ice collecting beneath the unit, arrange for it to be
drained away from the unit.
SEA COAST COIL MAINTENANCE
Coastal locations often require additional maintenance of the
outdoor unit due to highly corrosive airborne ocean salt. Although
your new Bryant system is made of galvanized metal and is
protected by top--grade paint, take the additional precaution of
periodically washing all exposed surfaces and the outdoor coil
approximately every 3 months. Consult your installing Bryant
dealer for proper cleaning intervals and procedures for your
geographic area or ask about a service contract for regularly
scheduled professional cleaning and inspections.
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bryant Evolution 189BNV wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info