Structure
Figure
Clear button
Quitting the programming mode
On / Enter button
Readiness for opening
LED goes on when a valid opening code is entered and programming
is successful.
Battery replacement symbol
When this LED is on, please replace all 3 batteries
(LR6 / AA / 1.5V / Alkaline).
Readiness for entry / programming
The LED goes on when the programming mode is entered. It goes o when
the programming mode is exited again.
Rejected entry / blocking time
The LED goes on when an invalid code is entered or when the programming
is incorrect. In case a wrong code is entered three times in a row, the lock is
blocked for 5 minutes. During this time, the LED ashes. In this status, opening
is not possible, even with a correct opening code.
Dear customer,
Thank you for deciding for a safe with the BURG-WÄCHTER TRSE10 electronics.
This electronics is certied according to VdS class 1 and opening is possible both
with ngerprint and using a Pincode. You have thus acquired a product meeting
extremely high security requirements and developed and manufactured using the
latest technical potential.
Important: Please read the entire User Manual before programming
and store this User Manual at a safe place for future reference at any time
you may need it.
We hope you will enjoy your BURG-WÄCHTER safe.
Your BURG-WÄCHTER KG
Important remarks
In order to enhance the protection against intrusion, the following points
should be observed:
No personal data (e. g. dates of birth) or other data, for which a link can be
derived from the code owner, should be used for coding.
If the code is stored in writing, such document should be consistently stored
safely, so that it is accessible only to the authorized persons.
Attention: Any changes of the Pincode shall be made with the safe
door opened!
When the locking system has been reset to another code, this new code should
be repeatedly used with the safe door opened.
Generally
A Pincode and 10 memory slots for ngerprints are available for opening.
Pincode: 123456 (factory setting)
The Pincode has always 6 digits.
For ngerprint opening, two dierent ngers need to be used, which have to be
dragged over the sensor successively.
When an action has been successfully completed, the green LED goes on.
Technical data
Number of Pincodes 1
Number of
ngerprints
10
Blocking times When a wrong code is entered 3 times, 5 minutes,
subsequently 10 minutes after each wrong entry
Power supply 3 x MIGNON LR6 / AA / ALKALINE
Permissible ambient
conditions
- 15 °C through +50 °C
Up to 95 % rel. air humidity (non condensing)
Menu structure
The individual labels on the keypad indicate numerals and letters. Combinations
of numerals and / or letters are used to program the individual functions. The initial
letters of a programming procedure are composed as a combination of numbers
(to facilitate their remembering). When using these explicit combinations,
the individual submenus are opened.
Opening with Pincode
Press „On / Enter, the yellow LED of the Readiness for entry / programming
icon goes on.
Enter the Pincode. The green LED goes on when entered correctly, the red one
when the entry is rejected.
Turn the rotary handle clockwise to open the door.
Opening with nger
Press „On / Enter, the yellow LED of the Readiness for entry / programming
icon goes on.
Move your 1st nger over the sensor.
The yellow LED goes o, the green LED goes briey on when the nger is
accepted, then the yellow LED goes on again.
Move your 2nd nger over the sensor.
The yellow LED goes o, the green LED goes briey on when the nger is
accepted.
Turn the rotary handle clockwise in order to open the door.
bat
Access to the programming mode to change
the lock settings
Press „On / Enter, the yellow LED of the Readiness for entry/programming
icon goes on.
Type numbers 76 (program mode), the yellow LED goes o.
Press „On / Enter“ and enter the valid Pincode.
When a valid Pincode has been entered, the green LED goes on briey,
subsequently the yellow LED ashes. As long as the yellow „Readiness for
entry / programming“ LED is ashing, you are in the programming mode and
so you can perform various actions.
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Burg-Wachter TRSE 10 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Burg-Wachter TRSE 10

Burg-Wachter TRSE 10 Bedienungsanleitung - Deutsch - 3 seiten

Burg-Wachter TRSE 10 Bedienungsanleitung - Holländisch - 3 seiten

Burg-Wachter TRSE 10 Bedienungsanleitung - Französisch - 3 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info