The following table shows the factory pre-set programme,
which may be re-instated at any time by performing a
RESET.
Days 1 to 5 (Weekdays) Days 6 & 7 (Weekend)
Setting Time Temp. Setting Time Temp.
1 6:30 20 1 7:00 20
2 8:30 15 2 16:00 21
3 11:30 20 3 23:00 15
4 13:30 15 4 0:00 15
5 16:30 21 5 1:00 15
6 22:30 15 6 1:59 15
The factory pre-set programme for days 6 & 7 (Saturday
and Sunday) provides full heating throughout the day
until 23:00, after which the 15°C may be raised manually
to the level required using the s button. The manual
over-ride will last for up to one hour until midnight (0:00)
after which it can be used up to twice again to provide full
heating until 1:59 if required.
CHANGING THE SETTINGS
While reviewing the settings the switching time and
control temperature may be changed using the + and -
(time) and s and t (temperature) buttons.
When changing the switching times it is not possible to
set the times out of sequence.
This important feature works like this:
Both number 1 time settings can be placed at any time of
the day, although they would usually be in the morning.
Each of the time settings 2 to 6 can only be placed
between the previous setting and 1:59.
When using the - button to change settings 2 to 6 the
button stops responding when the previous setting time
is reached. While using the + button to change settings
2 to 5, as later settings in the sequence are reached the
time continues to advance, (until 1:59 if the button is held
down), and all later settings reached are then changed to
the same time as the one being set.
Should this happen unintentionally and settings 2 to 6 are
all at the same undesirable time, use the PROG button to
get back to setting 1, days 1 to 5, then review and change
all the times and temperatures to the required settings. If
any times are intentionally set to the same time then the
temperature associated with the higher setting number
will be used to control the room temperature.
INITIAL START-UP
Slide the battery cover to the left to
reveal the programming buttons
(PROG, +, -). Slide the cover further
left to reveal the battery compartment.
Fit the batteries (supplied) making sure
the + ends align with the symbols at the back of the
compartment. RESET the TP5E as described below.
The blank display changes to that shown in fig. 1. (If the
actual air temperature in the proximity of the unit is higher
than 20°C the flame symbol will not be displayed). Slide
the battery cover to the right but leave the buttons visible.
RESET
The TP5E may be reset to the factory pre-set programme,
12:00 on day 1, and 20°C by pressing and holding down
the four buttons, temperature s and t , time + and -, until
the display becomes blank. This may be necessary after
a severe electrical storm or serious fluctuations in the
electricity supply, indicated by a malfunction or spurious
information such as 18:88 on the display.
SETTING THE CLOCK
Press the PROG button once; the colon
stops blinking, (see fig. 2). Use the +
and - buttons to set the time. Pressing
and releasing these buttons changes
the time by one minute, holding these
buttons down changes the time quickly.
When the time is correct press the
PROG button to start the clock; now
only the colon and day number are
displayed, (see fig. 3). Use the + and -
buttons to select the correct day
number. (It is intended that day 1 is
Monday, therefore days 6 and 7 are
Saturday and Sunday - the weekend).
Press PROG to display the first setting,
(see fig. 4).
REVIEWING THE EXISTING
SETTINGS
Now each press of the PROG button
shows, in sequence, the twelve set
times and their associated control
temperatures, starting at setting 1, days
1 to 5, and finishing at setting 6, days 6
& 7, (see figs. 4 to 6). Pressing PROG
while setting 6, days 6 & 7 is shown
returns the TP5E to RUN mode.
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Danfoss TP5E wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Danfoss TP5E

Danfoss TP5E Bedienungsanleitung - Holländisch - 2 seiten

Danfoss TP5E Bedienungsanleitung - Französisch - 1 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info