166113
4
Zoom out
Zoom in
Vorherige Seite
1/26
Nächste Seite
Connect the fuse holder as close to the vehicle battery
+ as possible, using AWG 5 = 16 mm
2
or heavier cable
(see table on page 2). Use ring crimp terminal cable
to connect to battery +. Apply silicon grease to the
fuse to prevent corrosion.
Connect the battery cable to the +12 Volt terminal
on the amplifier. Model A2, A5 and A7 accepts AWG
4 = 21 mm
2
direct into the terminal. Be sure to use a
rubber grommet or a plastic insulating tube where
the cable passes the firewall or other places where
it can easily be jammed.
Use wire ties to secure to existing cables in the
engine compartment.
Wiring
Power, remote and fan terminals
ULTIMATE A-series
Power terminal for A2, A5, A7
Remote terminal ( REM )
For RCA cable signal input:
Connect the radio power antenna lead = remote
turn on/off from the head unit to the amplifier remote
connection. This turns on the amplifier whenever
the car stereo is turned on.
You can either use the built in remote cable in the
RCA cable itself, or use a separate cable.
Sometimes a small disturbance may enter the
amplifier coming from the remote voltage, through
the built in remote wire and into the RCA cable.
Thus we recommend to use a separate remote wire
and run the RCA lead separate from remote wire,
power cables and speaker cables.
You can insert the cable directly into the amplifier
terminal. If there is no remote voltage available from
the stereo, you must connect to the ignition key,
through the radio, or any accessories fuse.
4
DLS FH1B or
FH2B
fuse holder
Battery 12V
DLS
POWER IN
BATT+ REMOTE GND
Power terminal for A3, A4 & A6
These models have double DC inputs. The termin-
als are internally connected so it´s enough to
connect just one of them. If you want to reduce the
voltage drop to the amplifier, use both inputs. The
extra DC input can also be used for the connection
of a Power Capacitor or an extra battery. See the
example above. These amplifiers requires a
powerful fuse holder like the FH2B with an ANL 150
Amp fuse (when using 2AWG / 33 mm
2
power
cable).
Ground Terminal ( GND )
POWER IN
BATT+ REMOTE GND
FM1 107,3
Fuses
Use only ATC blade type
fuses. Make sure to replace
with the same value. The
value is printed above the
fuse holders. DLS A4 has no
internal fuses, use an
external fuse instead.
POWER IN
BATT+ REMOTE GND
Fan terminal
DLS A3, A4, A5, A6 and A7 has a fan
output terminal. On A3, A4 and A6
the terminal is combined with the
extra DC-terminal. The output is
electronically controlled and starts if
the amplifiers is overheated. The ter-
minal is marked "FAN”.
Use a 12 volt DC fan.The speed of
the fan increases when the tempera-
ture rises. Direct the fan towards the
amplifier cooling ribs. Full speed is
obtained at 70 degrees C. NOTE!
Maximum load on the FAN terminal
is 0,5 Amp.
Power
capacitor
Fuse
150 A
Fan12 V
To remote
on head unit
POWER IN
BAT+ REM GND
POWER IN /POWER CAP
GND FAN OUT POS+
PROTECT
POWER
+
Battery
12 volt
Connect to a good chassis ground. The ground
connection should be clean, unpainted metal to prov-
ide a good electrical connection. Use a wire brush,
a scraper or a piece of an abrasive sheet to clean
the metal. Use a lock washer or two to secure
contact. Protect with silicon grease or by paint
applied afterwards.
Fan 12 V
FAN
- +
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für DLS a 3 ultimate wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info