What is a room t hermos tat?
... an explanation for householders
A ro om t her m os t a t sim pl y sw i tc he s th e hea t ing
sy s te m on a nd o f f a s ne ce ss ar y. It wo rk s by s en si ng
th e air t em pe ra tu re, s wi t chi ng o n th e he at ing w he n
th e air t em pe ra tu re f al ls b el ow th e th er m os t at s e t t ing ,
an d sw it ch in g it o f f on ce t hi s se t te mp er at ur e ha s
been reached.
T urn in g a roo m th er mo s t at t o a hig he r se t t in g wi ll no t
make t he r oo m he at u p any f as t er. How q uic k ly t he
ro om he at s u p de pe nd s on t he d es ign o f th e he at ing
sy s te m, f or ex am ple , th e siz e of b oil er a nd r ad iat or s .
Ne it he r do es t he s et ti ng a f f ec t how q uic k ly t he r oo m
co ol s dow n. Turn ing a r oo m th er mo s t at t o a low er
se t t in g wil l re sul t i n th e roo m be in g con t rol le d at a
lower temperature, and sav es energy .
Th e he at in g sy s te m wi ll no t wo rk i f a ti me s wi tc h or
pro gr am me r ha s sw i tch ed i t o f f.
Th e way t o se t an d us e yo ur ro om t he rm os t a t is t o
fi n d t he lo we s t te mpe r at ure s e t t ing t ha t yo u are
co mfo r t a bl e wi th , and t he n le ave i t al on e to do i t s jo b.
Th e be s t wa y to do t hi s is t o se t th e ro om t her m os t at
to a l ow te mp er at ur e – say 18 ºC – a nd t he n tu rn i t up
by on e de gr ee ea ch d ay un t il yo u are c om fo r t ab le
wi th t he t em pe ra tu re. You wo n’t h ave t o adj us t t he
th er mo s t at f ur th er. Any a dju s t me nt ab ov e thi s se t t in g
wi ll wa s te e ne rg y and c os t y ou m ore m on ey.
If y our h ea ti ng s ys t em i s a bo ile r wi t h ra dia to rs , t her e
wi ll us ua lly b e on ly o ne r oom t h er mo s ta t to c on tr ol t he
whole house. But you can have dif ferent temperatures
in individual rooms by inst alling thermos ta tic radiator
va lve s ( TR Vs) on ind iv id ual r a dia to rs . If y ou d on’ t
hav e TR Vs, yo u sh ou ld c hoo s e a tem pe ra t ure t ha t is
rea so na bl e for t he w ho le h ou se. I f yo u do ha ve T RVs,
you c a n ch oo se a s li ght l y hig he r se t t ing t o ma ke
sure that even the coldest room is comfortable, then
pr eve nt an y ove rh ea ti ng in o th er r oo ms by a dju s t ing
the TRV s.
Roo m th er m os t at s n ee d a f re e fl o w of ai r to s en se
th e te mp er at ure , so t hey m us t n ot b e co ver ed by
cu r t ai ns o r bl oc ked by f ur n it ur e. Ne ar by el ec tr ic
fi r es , te le vi sio ns , wa ll or t a ble l am ps m ay pr eve nt t he
thermos tat from working properly .
MiS tat
TM
N
Ro om Thermos t at
Model : N 1 1 0R
Cu s to me r Se r v ic e T el: 0 84 5 1 30 5522
Cu s to me r Se r v ic e Fax : 08 45 130 0622
T echnical Helpline: 0845 1 30 7 7 22
Website: w w w.dray toncont rols .co.uk
Email: customer. care@draytoncontrols .co .uk
l
@Dray tonControls
x
/Dray tonControls
EU De si gn Re gs :- 0021806 38 -1 / 2 /3
Us er G uid e 06 4901 91 001 Is s F
HOM EO WNER Guide
HOM EO WNER Guide
Symbol in
dis play
Function Description
Comfor t setting
Se le c t s t he c omf or t se t t in g. T he p re - se t va lue i s us ed e ac h ti me w hen a c t iv at ed ,
ad jus t a bl e wi th in t he us er s e t t ing s (se e s te p 3).
Eco setting
Se le c t s t he Ec o se t t in g. T he p re -s e t val ue i s us ed e ac h tim e wh en a c t iv at ed,
ad jus t a bl e in th e us er s e t t ing s (se e s tep 3).
None
Home screen
In dic a te s th at t he p re - se t tem pe r at ure s we re c han ge d vi a +/- key
S t e p 1: Ke ys and Display - MiStat
RF Pack: M iStat N1 1 0R
St e p 2: +hr (Timer )
MiStat
Pre s s +hr to s t a r t t he T im er. The p r ior u se d
te mpe r at ure a nd t im e wi ll be d is pl aye d and t h e
temperature wi ll fl ash.
MiStat
Pre s s +/- t o ad jus t +h r te mp er at ur e, th en pr es s ( )
t o c o n fi r m .
Pre s s +/- t o ad jus t +h r pe ri od b et we en 0 an d 23 ho ur s .
Pre s s (
) t o c o n fi r m .
S t e p 3: Additional User Se t tings
ID Fe atu re: Descri ption: Factor y Pre-Set:
1 M A X-T E M P
It w il l no t be p os si bl e to s et a
higher temperature
If M A X-TE MP a nd M IN -TEM P ar e se t to t h e
sa me v al ue, i t wi ll n ot b e po s sib le t o ch an ge
te mp er at ur e wi t h th e +/- keys .
30°C
2 MIN-TEMP
It w il l no t be p os si bl e to s et a
lower temperature
5°C
3 E CO -T E M P
ECO Temp er a tu re us e d fo r ene rg y s avi ng p er io ds e .g. d ur in g th e ni gh t ( )
16° C
4 COMF- TEMP
Co mf or t T emp er a tu re u se d fo r co mf or t p er io d s e.g. d ur in g th e da y ( )
21° C
DONE
E xi t f rom t h e se t t ing s m enu t o US ER- S
T o enter User Settings
Pre s s + & – keys f or a ppr ox . 5
Seconds to enter the settings
me nu a s sho wn b el ow.
Pre s s Se le c t (
) to en te r th e us er
set tings.
Batter y Handling
Ba t te ri es , r ec ha rg ea bl e or n ot , s ho ul d no t be d is po s ed
of i nt o or di na r y h ou se ho ld w as t e. I ns t ea d, t he y mu s t be
recycled properly to protect the environment and cut down
the waste of precious resources.
Your lo c al w as t e ma na ge me n t au th or it y c a n su pp ly d e ta il s
concerning the proper disposal of batteries.
In c om pl ia nc e wi th t h e EU Di re c t iv e 200 6/66/ EC , t he b ut to n
ce ll b at t er y l oc a te d on t he p ri nt ed c i rc ui t bo ar d in si de t h e
pr od uc t, c an b e r em ove d at t he e n d of t he p ro du c t l if e, by
professional personnel only.
St e p 4: Changing the Bat teries
How do I kn ow when to ch ange
the bat teries ?
Wh en t he b at ter i es s t ar t to r un l ow a b at ter y ic on wi ll
fl a sh i n th e di sp lay t o ind ic a te “l ow b at ter y ” , dur in g
th is t ime t he M iSt a t wi ll f un c ti on n or ma ll y. Whe n
th e ba t t er y i co n alo ne i s sh ow n in t he di sp lay, th e
ba t t er ie s are c om pl ete ly e xh au s ted a nd t he M iSt a t wi ll
ce as e to f un c t ion (se e b elo w). Re -a c t iv at e by re pl ac ing
the batteries.
How to rep lace the b at ter ies
Rem ove t he b at te r y c over s a s sh ow n. Re pl ace t he b at te ri es w it h 2 x 1.5V I EC L R6 (A A) A lk al ine b at te ri es e ns ur ing
correc t orientation. Replace the batter y covers pressing fully home.
Batter y Covers:
Slide out wards
to remove
MiSt at Rear
S t e p 5: Receiv er - K ey & LED
La mp
colour
Mode Ac tion Key
Function
Green Normal Cal l fo r hea t
(boiler is fi r ing)
None
Green
Flashing
Normal RF
communicat ion
None
Off Normal No c all f or h ea t
(bo ile r is n ot
fi r i n g )
None
Red RF l os s
or n ot
bound
No c a ll fo r he at Swit che s
the boiler
On
Amber RF l os s
or n ot
bound
Ca ll f or h ea t Switches the
boiler Of f
LE D: Se e ta bl e be lo w for d et a ils
Key : Se e ta bl e be low f or d et ai ls
MiStat
MiStat
T o se t a sui t ab le t emp er a tu re fo r up t o 23 ho ur s, e.g .
for short term absence.
No w th e ti mer i s r unn ing . Th e t ime w ill b e co un te d
dow n ea ch h ou r .
On ce t he t im e has e la ps ed , con t rol r et ur ns t o th e pr io r
temperature screen.
Th e T ime r c an b e ca nc el le d by pr es si ng
key or by
se t t in g th e +hr p er io d to 0.
T o exi t Us er S e t ti ng s
Pre s s + & – key s for a pp rox . 5
seconds to exit.
If t he re i s no key p re ss ed f or
2 min u tes , t he s ys t em w ill e xi t
th e me nu, a ny ch an ge s wi ll be
saved .
T roubleshooting :
1 Set ting temperature values is restric ted
a
Are Minimum/Maximum tempera tures acti vated?
se e Ho me ow ner G ui de St ep 3 .
2
NO S IG NA L is v is ibl e on t he s cr ee n, no r eac ti on on
key p res s es a nym or e
a
Is t he r ec eiv er p owe re d? (Re d si gna l la mp s hou ld
be visible )
3 LOCKED is display ed
a see Inst allation Guide Step 5 - LOCK
MiStat
Current set temperature
Call for heat indication.
Th is fl am e wi ll be v is ib le
when the heating
temperature is below
th e se t te mp er at ur e.
+hr k ey: P res s t o se t a
suitable temperature
fo r up to 23 h ou rs (s ee
s t e p 2) .
Select key: Pres s
to o pe n and s av e
editor screen s
+ & - key s:
Pre s s to c han ge
th e cu rr en t
temperature.
Current room temperature
Current Set ting,
se e t abl e be lo w
key: Pres s to toggle
bet ween Comfor t
set ting, E co setting a nd
Home
(Room thermos tat only) .
Se e t abl e be lo w.
Customize the controller according to personal requirements.
4 Is t he b at t er y s y mbo l vi si bl e?
a Rep la ce b at t er ie s, s ee H om eow ne r Gu ide S te p 4.
5
STAR TI NG i s vi si bl e on t he sc re en , no re ac t io n on ke y
presse s anymore
a
Is t he r ec eiv er p owe re d? (Re d si gna l la mp s hou ld
be visible )
6
WAI T is v is ibl e on t he s cr ee n, no r eac ti on on ke y
presse s anymore
a
Is t he r ec eiv er p owe re d? (Re d si gna l la mp s hou ld
be visible )
RF transmis sion indication. The
RF s y mb ol w ill b e vi si ble a s
follows ,
Sh or t fl a sh es = R F tr a ns mis s ion
Continuous fl ashing = RF signal
issue