14. OVERVIEW
Indicator (LED)
Supervision mode without acoustical monitoring
Supervision mode with acoustical monitoring
Supervision mode inactive
During phone connection
Alarm independent of alarm unit state (armed or disarmed)
active on„Default value“
1)
Cause of alarm
I II III
Entry-Delay Connection mode Announcement
Emergency (Sensor-2)
2)
Delayed Hands-free connection „Emergency call activated“
Sensor-3
3)
Un-delayed Listening-in connection „Alarm due to sensor 3“
1.) Default values without en without consideration of user specific programming in accordance to section 5
2.) Emergency call activation according to section 5.2.2: An emergency call will be triggered, if the button has been
activated for one second. After a pre alarm period of 20 seconds EasyAlarm
®
starts dialling calling number(s) and a
hands-free connection is established. During the pre warning period the alarm can be cancelled by pressing the
emergency button respectively by pressing key 0 .
3.) Sensor-3 activation according to 5.3.1.
Alarms only if alarm unit is armed
active on
„Default value“
1)
Cause of alarm
I II III
Entry-Delay Connection mode Announcement
Sensor 1
4)
Un-delayed Listening-in connection Alarm due to sensor 1“
Presence verification
5)
10 Minutes/30
Seconds
Hands-free connection
“Alarm due to presence
verification”
Sensor 2
6)
Un-delayed Listening-in connection Alarm due to sensor 2“
Noise (Babyphone)
7)
Un-delayed Listening-in connection „Alarm due to noise
Mains power loss
1 Minute Hands-free connection „Alarm due to power failure “
4.) Sensor-1 activation according to 5.1.1.
5.) Sensor-1 can be used to verify if a person is present ( section 5.1.2), i.e. an alarm will be triggered if no motion is
detected within 24h. Before starting the alarm there is a pre warning period of ten minutes. If activation is detected
(motion detected or emergency button pressed) within this period, the alarm is cancelled, otherwise EasyAlarm
®
establishes a hands-free connection
6.) Sensor-2 activation according to 5.2.
7.) Noise monitoring according to 5.4: To avoid false alarm while acoustical monitoring, close windows and try to
eliminate sources of noise.
8.) EasyAlarm
®
monitors mains voltage and triggers an alarm if power loss is longer than 10 to 20 minutes (=> time-out
according to section 10.4). During a pre warning period of 1 minute the following message is announced „Alarm due
to power failure“. After this period EasyAlarm® dials the programmed number and a hands-free connection is
established. If EasyAlar does not detect mains power during start up the monitoring remains inactive => „Power
failure“ is announced ! As soon as mains power is detected, EasyAlarm® starts to supervise mains power
Alarm release renewed
After an alarm EasyAlarm® remains inactive during a waiting period of two minutes. Only if at expiration of this
waiting period an alarm event occurs again, a new alarm is released. After an alarms through to sensor-1/2/3 a renewed
alerting comes off only if to the alarm contact returned to the state of rest.
Tone-dialling commands
DTMF => Every valid command will be signalled
0 Terminate phone connection and acknowledge alarm
1 Switching to hands-free mode and restart connection time-out
2 Repeat announcements (Individual message / Cause of alarm)
3 Restart connection time-out (2 minutes)
4 Deactivate output (i.e. switching off alarm siren)
5 Announcement of current supervision mode as well as condition of the output
6 Activate output (i.e. switching on the alarm siren)
7 Change to inactive supervision mode (I, II, III) => monitoring for noise, sensor-1, sensor-2, mains failure and
presence verification inactive. Emergency call and sensor-3 alarm are still possible.
8 Terminate phone connection without acknowledgment
9 Change to active supervision mode (I, II, III) => All monitoring functions re-activated
Noise
Nois
4 seconds
4 seconds
4 seconds 4 seconds
Telephone connection
32

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für EasyAlarm CONTROL wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von EasyAlarm CONTROL

EasyAlarm CONTROL Bedienungsanleitung - Deutsch - 32 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info