802371
2
Zoom out
Zoom in
Vorherige Seite
1/2
Nächste Seite
2
Measuring steps
1. Remove the battery compartment cover and insert the
batteries as shown in Figure 1. Securely re-fit the battery
compartment cover.
2. Press the power / function button on the front panel to
switch on the device.
3. Squeeze one end of the device to open it and place an
index finger inside. Allow the device to gently close on the
finger as shown in Figure 2. (Index, middle or ring fingers
can be used for a reading)
Keep the finger and device still with as little movement as
possible and allow the device to take a measurement.
Ensure the finger is inserted far enough into the sensor so
that the fingernail is just opposite to the light emitted
from the sensor.
Figure 1 Figure 2
Do not perform SpO² monitoring and NIBP (Non-invasive
blood pressure) measurements on the same arm
simultaneously. Obstruction of blood flow during NIBP
measurements may adversely affect the reading of the
SpO² value.
Do not use the Pulse Oximeter to measure patients whose
pulse rate is lower than 30bpm, as this may cause incorrect
results.
Ensure there is no contamination and/or scars on the tested
finger as the result indicated may be incorrect due to the
signal received by the sensor being affected.
When used on various patients, the product is prone to
cross contamination, which should be prevented and
controlled by the user. Disinfection is recommended before
using the product on other patients.
The highest temperature threshold of the sensor contacts
with a patient’s skin is 41°C.
Repeat use may require the use of different fingers to
obtain a measurement.
Factors affecting measurement accuracy
Incorrect placement of the finger may affect the accuracy of
the measurement.
The measurements also depend on absorption of a special
wavelength ray by oxidized hemoglobin and
deoxyhemoglobin. Concentration of nonfunctional
hemoglobin may affect the accuracy of the measurement.
Always consult a doctor if in doubt.
Shock, anemia, hypothermia and the application of
vasoconstriction drug may decrease arterial blood flow to
an unmeasurable level.
Pigment, or deep color (for example: nail polish, artificial
nails, dye or pigmented cream) may cause inaccurate
measurements.
Rotate the display
To rotate the display for convenient reading, when the
result has been displayed on the screen, short press the
“POWER/FUNCTION” button once.
Auto switch off
The product will switch off automatically after 10 seconds
of no signal being detected.
Transfer of measurement results
to your smartphone (via Bluetooth)
Thanks to the integrated Bluetooth function, you can
transfer the measurement results to your smartphone.
1. Switch on the Bluetooth function on your smartphone.
2. Download and install the app "SMART WEAR".
ANDROID IOS
3. When installing, follow the steps described in the app
and connect to the SP001 device.
4. The next measurement is automatically transferred
from the Pulse Oximeter to your smartphone.
5. This allows you to save the measurements as an image,
send them or share them with others.
Lanyard placement
1. Thread the thinner end of the lanyard through the hole.
2. Thread the thicker end of the lace through the threaded
end before pulling it tightly.
Cleaning and disinfection
Clean the product with cotton or damp soft cloth.
After cleaning, wipe dry and allow to full air dry.
Disinfection
The recommended disinfectants include: ethanol 70%,
isopropanol 70%, glutaraldehyde (2%) solution
disinfectants.
Clean the product as instructed above.
Disinfect the product with cotton or soft cloth moistened
with one of the recommended disinfectants.
After disinfection, be sure to wipe off the disinfectant left
on the product with a soft cloth moistened with water.
Allow the product to air dry.
Never immerse the device in liquid.
We recommend cleaning and disinfecting the product when
necessary or when used with different patients.
Never use cleaning agents/disinfectants other than those
recommended.
Never permit high-pressure and high-temperature
disinfection of the device.
Always switch off the device and remove the batteries
before cleaning or disinfecting.
Disposal
Dispose of packaging
Before disposal, please ensure separation of
the different packaging included with this
product. Cardboard must be disposed of as
paper while foil or plastics must be recycled.
Disposal of Waste Electrical and Electronic
Equipment and/or Battery by users in private
households in the European Union.
This symbol on the product or on the packaging indicates
that this cannot be disposed of as a household waste. You
must dispose of your waste equipment and/or battery by
handling it over to the applicable take-back scheme for the
recycling of electrical and electronic equipment and/or
battery. For more information about recycling of this
equipment and/or battery, please contact your city office,
the shop where you purchased the equipment or your
household waste disposal service. The recycling of materials
will help to conserve natural resources and ensure that it is
recycled in a manner that protects human health and
environment.
Declaration of conformity
We hereby declare that the CE marking has been affixed to
this product in accordance with the essential requirements
and relevant provisions of the European directives.
The declaration of conformity can be downloaded here:
www.easypix.info/download/pdf/
doc_pulseoximeter_po2.pdf
This explanation is given for the manufacturer / importer
easypix GmbH
Em Parkveedel 11
50733 Köln, Germany
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Easypix PO2 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Easypix PO2

Easypix PO2 Bedienungsanleitung - Deutsch - 2 seiten

Easypix PO2 Bedienungsanleitung - Holländisch - 2 seiten

Easypix PO2 Bedienungsanleitung - Französisch - 2 seiten

Easypix PO2 Bedienungsanleitung - Italienisch - 2 seiten

Easypix PO2 Bedienungsanleitung - Portugiesisch - 2 seiten

Easypix PO2 Bedienungsanleitung - Spanisch - 2 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info