7.2 Automatic group cleaning and degreasing of the brew groups
A brew group cleaner (in powder or tablet form) is available at your specialized dealer. The cleaning is carried out
using the blind filter included with delivery.
1 Heat up the machine.
2 Insert the blind filter into the porta filter.
3 Fill the blind filter with the group cleaning powder or with one tablet.
4 Clamp the porta filter into the brew group.
5 Start the brew group cleaning mode by simultaneously pressing the Star-button and button no. 1 on the key pad
of the respective brew group. The cleaning mode commences, a flashing light appears on the control panel
which blinks on and off in several intervals. The cleaning program stops automatically after five cleaning cycles
(the pump runs for 15 seconds, turns off for 20 seconds, runs for 15 seconds, etc.).
6 Remove the porta filter with the blind filter and rinse it with fresh water. Then clamp it back into the brew group.
7 Start the cleaning cycle again without using detergent and repeat step no. 5.
8 Afterwards, unclamp the porta filter, take out the blind filter and reinsert the coffee filter into the porta filter.
Clamp the porta filter back into the brew group.
Caution!
Beware of hot water sprayings while cleaning the brew group.
7.3 Draining the boiler
1 Heat up the machine and then switch the machine off.
2 Interrupt the water supply by closing down the fixed water connection.
3 Open the hot water valve (caution: hot water may spray).
4 The water is released into the collection container through the drainage hose.
5 When the boiler is empty, close the hot water valve.
(If you have any questions, please contact your specialised dealer.)
7.4 Maintenance
Replacing the group gasket and the shower screen
1. Switch off the machine, disconnect the power cord and make sure that the machine is cooled down to room
temperature.
2. It is recommended to remove all the removable parts (cup warming tray, water tank, drip tray), then turn the
machine over.
3. Loosen the countersunk screw in the middle of the brew group and the shower plate with an Allen key
(3 mm)
4. The shower screen and the shower holder (brass) can be removed easily.
5. Under the shower holder is a thin ring, the gasket of the shower plate (item. no. C449900790).
6. The group gasket (item no. C449900229) can only be removed by inserting a thin screwdriver between shower
holder and group gasket. Pry out the group gasket (the old group gasket will be damaged / destroyed).
7. Clean the groove completely, before installing the new group gasket. When inserting the group gasket, make
sure that the bevelled side (side with ECM on it) is facing upwards so that it is no longer visible.
8. Press the group gasket gradually into the pre-cleaned groove.
9. Then screw in the shower plate (item no. C519900102) and the shower holder.
10. In order to ensure that the group gasket is inserted properly, carefully clamp a portafilter without filter into the
brew group.
21

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Ecm Compact HX-2 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info