Technical data
8
THISION L EVO
60 70 80 100 120 140
Nominal heat output at 80/60°C max/min
kW 56,5/15,5 65,5/15,6 75,3/19,4 92,9/18,7 111,9/22,5 130,4/26,2
Nominal heat output at 50/30°C max/min kW 60,4/17,2 70,0/17,2 79,7/21,2 98,9/20,6 118,5/24,8 137,8/28,9
Nominal heat output at 40/30°C max/min
kW 60,5/17,3 70,0/ 17,4 79,7/21,5 98,9/20,9 118,5/25,2 137,8/29,3
Nominal heat input Hi max/min kW 57,9/16,0 66,8/16,0 76,8/19,8 95,2/19,0 114,3/22,9 133,3/26,7
Modula on ra o - 3,6 4,2 3,9 5,0 5,0 5,0
E ciency at 80/60°C max/min
% 97,6/97,0 98,0/97,5 98,0/97,9 97,6/98,3 97,9/ 98,3 97,8/ 98,3
E ciency at 50/30°C max/min
% 104,4/107,4 104,8/107,3 103,8/107,2 103,9/108,5 103,7/108,4 103,4/108,3
E ciency at 40/30°C max/min
% 104,5/108,3 104,8/108,5 103,8/108,6 103,9/110,0 103,7/109,9 103,4/109,8
E ciency at 36/30°C load 30%
% 107,2 107,2 107,1 107,8 107,9 107,6
RAL 40/30 average
% 108,7 109,1 109,4 109,4 109,1 108,7
Heat Loss (Pstby) W 81,0 81,0 81,0 92,7 92,7 92,7
Max. condensate ow l/h 3,6 4,4 4,3 5,4 6,4 7,1
Gas consump on G20 max/min (10,9 kWh/m
3
)
m
3
/h 5,3/1,5 6,1/1,5 7,0/1,8 8,7/1,7 10,5/2,1 12,2/2,4
Gas consump on G25 max/min (8,34 kWh/m
3
)
m
3
/h 6,9/1,9 8,0/1,9 9,2/2,4 11,4/2,3 13,7/2,7 16,0/3,2
Gas consump on G31 max/min (12,8 kWh/kg)
kg/h 4,5/1,3 5,2/1,3 6,0/1,5 7,4/1,5 8,9/1,8 10,4/2,1
Gas pressure G20
mbar 20
Gas pressure G25
mbar 25
Gas pressure G31 mbar 30/50
Maximum gas pressure
mbar 50
Max. temperature ue gas (high limit)
°C 90
Flue gas temperature at 80/60°C max/min
°C 59/57 60/57 61/58 60/56 63/56 66/57
Flue gas temperature at 50/30°C max/min
°C 43/35 44/34 45/33 44/33 46/33 48/33
Flue gas temperature at 40/30°C max/min
°C 42/33 44/33 44/33 43/32 45/32 47/32
Flue gas temperature at 36/30°C load 30%
°C 34 35 35 33 34 35
Flue gas quan ty max/min
m
3
/h 83/22 98/22 113/27 139/27 168/33 202/38
CO level at 80/60 °C max/min
ppm 75/11 92/11 87/7 67/5 82/4 62/7
CO level at 80/60 °C max/min
mg/kWh 80/11 99/11 94/7 72/5 88/5 67/7
CO year emission EN15502
ppm 35,79 43,76 51,73 41,53 40,76 39,99
CO year emission EN15502
mg/kWh 38,44 47,00 55,56 44,60 43,78 42,95
CO
2
level G20-G25
Max. load
%
8,5 (+0 -0,2) 8,4 (+0 -0,2) 8,4 (+0 -0,2) 8,4 (+0 -0,2) 8,4 (+0 -0,2) 8,2 (+0 -0,2)
Min. load
9,0 (+0 -0,2) 9,0 (+0 -0,2) 9,0 (+0 -0,2) 8,5 (+0 -0,2) 8,5 (+0 -0,2) 8,5 (+0 -0,2)
Restric on ΔCO2 max.load - min. load (G20-G25) % - - - - - <0,3
CO
2
level G31
Max. load
%
9,6 (0 +0,2)
Min. load
9,6 (0 +0,2)
Restric on ΔCO2 max.load - min. load (G31) % CO2 Min. load CO2 Max. load
NO
x
level at 80/60 °C max/min
ppm 26/10 30/11 34/16 26/11 22/15 15/15
NO
x
level at 80/60 °C max/min
mg/kWh 45/17 53/19 60/28 46/19 38/27 26/26
NOx emission EN15502 (ppm)
ppm 13,94 18,78 23,61 28,38 22,61 16,84
NOx emission Hi/Hs EN15502 (mg/kWh)
mg/kWh 24,60/22,15 32,61/29,36 40,61/36,57 46,67/42,03 38,19/34,40 29,71/26,76
NOx class EN15502
6
Max. permissible ue resistance
Pa 167 244 275 173 134 200
Water volume l 6 6 6 9 9 9
Water pressure max/min
bar 8/1 8/1 8/1 8/1 8/1 8/1
Max. water temperature
(High limit thermostat)
°C 100 100 100 100 100 100
Maximum temperature setpoint
°C 90 90 90 90 90 90
Nominal water ow at dT=20 K m
3
/h 2,4 2,8 3,2 4,0 4,8 5,6
Hydraulic resistance at nominal ow rate kPa 15 18 22 7 9 11
Electrical connec on
V 230
Frequency
Hz 50
Mains connec on fuse
A
10
IP class with Appliance Type B23(P) - IP30
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Elco THISION L EVO wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info