Zoom out
Zoom in
Vorherige Seite
1/8
Nächste Seite
AS1-GSM REV.1.1 01/02/2013
AS1-GSM
GSM based intercom and access control
Installation and user manual
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Inhalt der Seiten


  • Page 1

    AS1-GSM
    GSM based intercom and access control
    Installation and user manual

    AS1-GSM REV.1.1 01/02/2013



  • Page 2

    Table of contents

    1
    2
    3
    4

    Functions ..................................................................................................................................3
    Features ...................................................................................................................................3
    Application area........................................................................................................................3
    Operation .................................................................................................................................4
    4.1 Visitor mode .....................................................................................................................4
    4.2 Listen-in mode .................................................................................................................4
    4.3 Relay output control (gate opening) .................................................................................4
    4.4 Voltage output control (electric lock activation) ................................................................4
    4.5 Forwarding incoming SMS messages..............................................................................4
    5 Settings ....................................................................................................................................5
    5.1 Response SMS explanation .............................................................................................5
    6 LED indications ........................................................................................................................6
    7 Installation ................................................................................................................................6
    7.1 Mounting ..........................................................................................................................6
    7.2 Putting into operation .......................................................................................................6
    8 Wiring diagram .........................................................................................................................7
    9 Surface mounting…………………………………………………………………………...………...8
    10 Technical specification ............................................................................................................8

    2



  • Page 3

    The AS1-GSM is an intercom unit which as a cell phone can call the owner’s mobile or landline
    phone. By pressing the call button on the intercom, it makes the voice connection in a few
    seconds, just like when talking via a conventional intercom system. This way it makes possible
    for the owner to receive the visitor’s calls and talk to them at anytime and anywhere, even when
    not at home.
    The unit does not need internal handset, any special installation or complicated wiring, it needs
    power only and an active SIM card.

    1 Functions







    Intercom
    Listen-in mode
    Electric door lock control via DTMF codes
    Electric gate control by free call
    SMS forwarding
    Programming through SMS message

    2 Features








    GSM communication in full duplex mode
    2 configurable phone number for communication
    4 configurable phone numbers for electric gate control
    1 relay output with independent N.O. contact, supports 1A@24V max. load
    12V/1A voltage output with short circuit and overcurrent protection for electric lock control
    Local control of the voltage output using a separate input
    Supports prepaid SIM cards by forwarding the received balance information in SMS

    3 Application area




    Wireless intercom
    Gate/door opener
    Emergency call device

    3



  • Page 4

    4 Operation
    4.1

    Visitor mode

    When the visitor pushes the call button, the device initiates a voice call to the configured phone
    number. If the called party accepts the call, the communication establishes for the configured
    duration. During the call, the connection cannot be interrupted nor by making a call to the device,
    nor by pressing the button again. The call is ended automatically when the configured
    communication time expires, or the called party can hang up the call at anytime on his/her
    phone. The call is ended automatically if the called party does not answer or is not available.
    A new call is initiated only if the button is pressed again.
    A call to the second telephone number can be initiated for 60 seconds after the first call is
    ended, by pressing the call button on the intercom again. The maximum duration of the call is
    the same as in case of the first call.
    4.2

    Listen-in mode

    The intercom unit can be called from any phone number. In this case the unit accepts the call
    without ringing and the voice connection establishes. The call can be ended on the caller’s
    phone or by pressing the call button on the unit.
    If the call is initiated from a phone number which is configured in the unit as gate opener
    number, the device will consider the call as a gate opening call. In this case voice
    connection is not established, but the relay output is activated. To make a “listen-in” call
    from such phone number, use the #31# code in front of the number, this hides the caller’s phone
    number (e.g.: #31#0036301234567).
    4.3

    Relay output control (gate opening)

    The unit can activate an independent, normally open relay output by free call, using caller
    (phone number) identification. Up to 10 user phone numbers can be configured for this function.
    To use this function, caller identification service should be activated at the GSM service provider
    on the SIM card inserted in the unit, as well as the caller should send the ID (phone number)
    when calling. When receiving a control call, the unit identifies the caller, rejects the call and
    activates the relay output.
    4.4

    Voltage output control (electric lock activation)

    The voltage output can be activated for the configured duration during the phone conversation.
    This makes possible to control directly an electric lock. The activation of the output can be done
    by the called party by pressing any number or character key on the phone, thereby sending a
    DTMF code. The voltage output can also be activated locally, by closing the “INPUT” input on
    the unit. In this case the device will activate the output still for the configured duration. In case of
    a short circuit or overcurrent the output turns off, then it operates again after the termination of
    the fault.
    4.5

    Forwarding incoming SMS messages

    The unit forwards the SMS messages received on its SIM card (e.g. balance information in case
    of a prepaid card) to the phone number set with the TEL command. After forwarding, the
    received message is deleted from the SIM card. If there is no phone number configured, the unit
    deletes the incoming messages without forwarding. A forwarded SMS message looks as follows:
    SMS forward from „the sender’s phone number”: …the forwarded message...

    4



  • Page 5

    5 Settings
    Configuration of the unit is possible by sending the appropriate commands in SMS to the
    module’s phone number. It is possible to send more commands (settings) in the same SMS, but
    the length of the message must not exceed 140 characters! Each message must begin with the
    password using the PWD=password# command and each command must end with # character,
    else the module does not apply the modifications. The following table contains the configuring
    and query commands:
    Configuration commands
    PWD= 1234#

    Password for programming, default setting:1234

    PWC=new password#

    Changing the password. The password is a 4-digit number.

    RESET#

    Resetting the settings and the password to default.

    TEL=phone number#

    Setting the primary phone number to be called when pressing the
    button (in international format)

    TEL2=phone number#

    Secondary telephone number in case the first telephone number
    is unavailable.

    TIME=duration#

    Maximal duration of the conversation. (60-600 seconds)
    Default setting: 60 seconds

    RTIME= duration#

    Duration of the relay output activation.
    (1-100 seconds)
    Default setting: 3 seconds

    VTIME= duration#

    Duration of the voltage output (- OUT +) activation.
    (1-100 seconds).
    Default setting: 5 seconds

    RTEL= phone number#

    Setting the phone numbers for relay output activation.
    (max. 4 user)

    STATUS?#

    Query of the settings and the phone numbers set for relay output
    activation.

    Example: PWD=1234#TEL=00363012345678#TIME=120#RTEL=00363012345678#
    5.1

    Response SMS explanation

    After sending the configuration SMS, the unit sends back two SMS messages containing the
    modified setting and the phone numbers set for relay output activation. It sends the same
    messages when querying the status with the STATUS?# command, as shown in the following
    example:
    TEL: 00363012345678
    CALL TIME: 120
    SIGNAL: GOOD

    RTEL: 00363012345678

    the phone number called on button pressing: 00363012345678
    conversation duration (limited to 120 seconds)
    GSM signal (BAD / GOOD / EXCELLENT).
    If the indication is BAD, find a more suitable place for the unit or
    the GSM antenna, or a higher gain GSM antenna is necessary.
    phone number(s) authorized to activate the relay output.

    5



  • Page 6

    6 LED indications
    LED
    GSM OK

    Color
    Is lit if the unit is connected to the network and field strength
    green is appropriate.
    Appropriate field strength: 2 (on the scale of 0-5)

    red

    GSM / SIM ERROR

    CALL IN PROGRESS

    Is lit continuously if the unit is not connected to the network.
    The following cases are possible:
    - the GSM antenna is not connected or is faulty
    - the SIM card is not inserted, or PIN code request is not
    deactivated, or the card is faulty.

    green Call or conversation is in progress.

    VOLTAGE OUT

    red

    Voltage output activated (e.g. electric lock control)

    RELAY CONTROL

    red

    Relay output activated (e.g. gate control)

    7 Installation
    7.1

    Mounting







    7.2

    Measure the GSM signal with your mobile phone. It may happen that in the desired place of
    installation the signal strength is not satisfactory. In this case you can move the unit or the
    GSM antenna in a more suitable place before installation.
    Do not mount the unit where it could be affected by strong electromagnetic disturbances.
    Do not mount the unit in wet places or in places with a high degree of humidity.
    Connecting the antenna: the GSM antenna can be connected to the SMA connector. The
    antenna supplied with the unit provides good transmission under normal reception
    circumstances. In case of having signal strength problems or/and wave interference (fading),
    use other type of antenna or find a more suitable place for the unit.
    Inserting the SIM card: turn the SIM card with the metallic contact surface downwards
    towards the panel, and the cut corner should point towards the panel’s center. Insert the
    card in this position in the socket and press until it clicks. To remove the SIM card, push it
    towards the socket then pull it out.
    Putting into operation








    Disable PIN code request, voicemail and missed call notification service on the SIM card.
    Enable caller identification and caller ID sending service on the SIM card at the GSM service
    provider.
    Make sure the SIM card is inserted properly into its socket.
    Make sure the antenna is fixed properly into the SMA connector.
    Make sure the wiring is done as shown in the wiring diagram.
    Power up the unit (12-24V AC/ DC). Make sure the power supply is sufficient for the
    operation of the unit. If operating from a 16V AC transformer, the necessary current is min.
    300mA (5VA).

    6



  • Page 7

    8 Wiring diagram

    1.
    2.
    3.
    4.
    5.
    6.
    7.
    8.
    9.
    10.
    11.

    Call button input
    Local input for voltage output control
    Relay output - normally open contact (max. 24V DC/1A)
    Voltage output 12V DC/1A
    Supply voltage input 14-24V AC/DC
    Speaker output
    SIM card socket
    GSM antenna connector (SMA type)
    Status indicator LED’s
    Microphone input
    USB connector (only for maintenance)
    7



  • Page 8

    9 Surface mounting

    10 Technical specification










    Supply voltage:
    Nominal consumption:
    Maximum consumption:
    Max. load of the relay output:
    Voltage output / max. load:
    Operating temperature:
    Transmission frequency:
    Contents of package:
    Warranty:

    12-24V AC/DC
    100mA
    400mA @ 12VDC, 200mA @ 24VDC
    max. 1A @ 24V DC
    12V DC / max. 1A
    -20ºC - +70ºC
    GSM 900/1800 MHz (GSM 2G network)
    AS1-GSM unit, GSM antenna, security screws
    1 year
    8






Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Estom AS1-GSM wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Holen Sie sich Ihr Benutzerhandbuch per E-Mail

Geben Sie Ihre E-Mail-Adresse ein, um das Handbuch zu erhalten von Estom AS1-GSM in der Sprache / Sprachen: Englisch als Anhang in Ihrer E-Mail.

Das Handbuch ist 1,43 mb groß.

 

Sie erhalten das Handbuch in Ihrer E-Mail innerhalb von Minuten. Wenn Sie keine E-Mail erhalten haben, haben Sie wahrscheinlich die falsche E-Mail-Adresse eingegeben oder Ihre Mailbox ist zu voll. Darüber hinaus kann es sein, dass Ihr ISP eine maximale Größe für E-Mails empfangen kann.

Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info