763951
19
Zoom out
Zoom in
Vorherige Seite
1/22
Nächste Seite
True-rms Multimeter
Specifications
15
Specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C,
with relative humidity at 0 % to 90 %.
Extended specifications are available at www.fluke.com.
Maximum voltage between any terminal and earth ground........................600 V
Display
Digital .........................................................................................................................6000 counts, updates 4/s
Bar Graph..................................................................................................................33 segments, updates 32/s
Te m p e r a t u re
Operating..................................................................................................................-10 °C to 50 °C
Storage......................................................................................................................-40 °C to 60 °C
Temperature Coefficient.........................................................................................0.1 x (specified accuracy)/°C
(<18 °C or >28 °C)
Altitude
Operating..................................................................................................................2000 meters
Storage......................................................................................................................10 000 meters
Relative Humidity.......................................................................................................95 % to 30 °C, 75 % to 40 °C, 45 % to 50 °C
Battery...........................................................................................................................IEC 6LR61
Battery Life ..................................................................................................................400 hours typical, without backlight
Safety ............................................................................................................................IEC 61010-1: Pollution Degree 2
IEC 61010-2-033
Measurement CAT III 600 V
Ingress Protection.....................................................................................................IEC 60529: IP42 (non-operating)
Electromagnetic Compatibility (EMC)
International ................................................................................................................IEC 61326-1: Portable Electromagnetic
Environment CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy
that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected
to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be
potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and
radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate
protection to radio reception in such environments.
Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test
object.
Korea (KCC) ..............................................................................................................Class A Equipment (Industrial Broadcasting &
Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user
should take notice of it. This equipment is intended for use in business environments and not to be used in
homes.
USA (FCC) .................................................................................................................47 CFR 15 subpart B. This product is
considered an exempt device per clause
15.103.
19

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Fluke 116 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Fluke 116

Fluke 116 Bedienungsanleitung - Deutsch - 22 seiten

Fluke 116 Bedienungsanleitung - Holländisch - 22 seiten

Fluke 116 Kurzanleitung - Alle Sprachen - 2 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info