RS-1 AND RS-2 REMOTE SYSTEM CONTROL PANELS RS-1 AND RS-2 REMOTE SYSTEM CONTROL PANELS
R S - 1
MAINTAINED CONTACT
REMOTE CONTROL PANEL
The RS-1 Remote System Control Panel is an
attractively finished key switch designed for
use in single-gang wall mount boxes. It can
control, from one location, all Furman power
products that have
remote capability, such
as the Furman AR-PRO,
ASD-120, MiniPort-15,
MiniPort-20, PowerLink,
the PowerPort, PS-
8R, and the PS-PRO.
Multiple units can be
controlled simultane-
ously.
The RS-1 features a
two-position key oper-
ated switch, an indicator
LED, and can be easily
installed in any electrical switch box with a mini-
mum depth of 1-1/4”. On the rear is a printed
circuit board with a standard size terminal strip
for wiring connections.
The RS-1 may also be compatible with other
AC power distribution and sequencing prod-
ucts. Our Technical Support team will be
happy to advise you on your specific installa-
tion needs.
RS-1 SPECIFICATIONS:
Dimensions: 4.75” (H) x 2.75” (W) x 1.25” (D).
Finish: black epoxy powder coat.
R S - 2
MOMENTARY CONTACT
REMOTE CONTROL PANEL
The RS-2 Remote System Control Panel is
identical to the RS-1 in most respects, but with
a momentary function rather that maintained.
The key switch offers an enable/disable func-
tion.
The RS-2 can control
multiple power products
by wiring their control
inputs in parallel. The
RS-2 is ideal for instal-
lations requiring multiple
remote switches. For in-
stallations requiring only
one remote maintained
contact switch, we rec-
ommend the RS-1.
The RS-2 may also be
compatible with other AC power distribution
and sequencing products. Our Technical Sup-
port team will be happy to advise you on your
specific installation needs.
RS-2 SPECIFICATIONS:
Dimensions: 4.75” (H) x 2.75” (W) x 1.25” (D).
Finish: black epoxy powder coat.
RS-1 AND RS-2 WIRING
INSTRUCTIONS
Connecting the RS-1 or RS-2 Remote Control Panel
is easy. For the simplest of installations, a single pair
cable will suffice (standard 24-28 AWG telephone
wire is fine). This allows ON/OFF control only. To
enable the RS-1 or RS-2’s SYSTEM ON indicator, it
will be necessary to run a 2-pair cable.
Both Remote Control Panels are clearly labeled
on the rear panel adjacent to the terminal strip. For
single-pair wiring, connect the +V terminal of your
power product to the +V terminal of the RS-1 or RS-
2.
Next, connect the REM terminal of your power
product to the REM terminal of the RS-1 or RS-2,
and your installation is complete. Most newer Fur-
man products default to ON if the REM input is left
open or tied to GND. This allows normal front panel
operation if the unit is not being used with a remote
control panel.
It is recommended that where long wire runs (> 200
ft.) or noisy environments are encountered, 2-pair
cable be run, even if the indicator is not needed.
This allows rejection of AC noise and interference
by tying the REM input to GND when the unit is on.
For installations using 2-pair cable, +V and REM
connections are identical; just add wires from the
STAT terminal to STAT terminal, and GND terminal
to GND terminal.
Though the connection doesn’t require a shielded
cable, in particularly noisy environments a shielded
cable can be used by connecting the shield between
the GND terminals of the product and the RS-1 or
RS-2.
THREE YEAR
LIMITED WARRANTY
The Furman RS-1 and RS-2 are protected by a
limited three year warranty, covering defects in
materials and workmanship, provided that the
registration card is filled out and returned
by the
FPO
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Furman RS-1 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info