All the alarms are indicated with a buzzer (3 second beep every 10 seconds) The buzzer can be silenced by
pressing a key.
Chamber probe alarm
The alarm triggers if there is a fault with the chamber probe. The TEMPERATURE display shows the "Pr1" label
and the buzzer emits a sound. Any cycle in progress is interrupted, all the outputs are deactivated (except for light,
technical cabinet fans) and the buzzer emits a sound.
Core probe alarm
This alarm triggers if there is a fault with the core probe a core probe cooking cycle. The DISPA2 display shows the
"Pr2" label and the buzzer emits a sound. Any cycle in progress is interrupted, all the outputs are deactivated
(except for light, technical cabinet fans) and the buzzer emits a sound.
If the cycle in progress is timed, no signal is provided.
Motor circuit breaker
In the presence of a motor circuit breaker alarm, the display DISPA1 shows the "ALL" label flashing and the display
TIME is OFF. Any cycle in progress is interrupted, all the outputs are deactivated (except for light, fan speed,
technical cabinet fans) and the buzzer emits a sound.