6GMC-I Messtechnik GmbH
1 Scope of Delivery
1Test instrument
1 Shoulder strap
1 Battery pack
1 KS-PROFiTEST INTRO (Z503L)
1 Factory calibration certificate
1 Condensed operating instructions
1 Supplementary sheet with safety information
1 Comprehensive operating instructions available on the Inter-
net for download at www.gossenmetrawatt.com
2 Application
This test instrument fulfills all requirements of applicable European
and national EC directives. We confirm this with the CE mark. The
relevant declaration of conformity can be obtained from
GMC-I Messtechnik GmbH.
The measuring and test instrument allows for quick and efficient
testing of protective measures in accordance with DIN VDE 0100-
600:2008
(Erection of low-voltage installations; tests – initial tests),
as well as
ÖVE-EN 1 (Austria), NIV/NIN SEV 1000 (Switzerland)
and other country-specific regulations.
The test instrument complies with IEC 61557/EN 61557/
VDE 0413 regulations:
Part 1: General requirements
Part 2: Insulation resistance
Part 3: Loop resistance
Part 4:
Resistance of earth connection and equipotential bonding
Part 5: Earth resistance
Part 6: Effectiveness of residual current devices (RCDs) in TT and
TN systems
Part 7: Phase sequence
Part 10:Electrical safety in low-voltage systems up to 1000 V AC
and 1500 V DC – Equipment for testing, measuring or
monitoring of protective measures
The test instrument is especially well suited for:
•Systems setup
Initial start-up
Periodic testing
Troubleshooting in electrical systems
All of the values required for approval reports (e.g. per ZVEH) can
be measured with this test instrument.
All acquired data can be archived, and measurement and test
reports can be printed out at a PC. This is of special significance
where product liability is concerned.
The applications range of the test instrument covers all alternating
and three-phase current systems with nominal voltages of 230 V /
400 V (300 V / 500 V) and nominal frequencies of 16⅔ / 50 / 60 /
200/ 400Hz.
The following can be measured an tested with the test instrument:
Voltage / frequency / phase sequence
Loop impedance / line impedance
Residual current devices (RCDs)
Earth resistance / earth loop resistance (relative to the mains)
Insulation resistance
Low-value resistance (potential equalization)
Voltage drop
Refer to section 19.3 regarding testing of electrical machines in
accordance with DIN EN 60204.
Refer to section 19.3 for periodic testing in accordance with
DGUV regulation 3 (formerly BGV A3).
2.1 Using Cable Sets and Test Probes
KS-PROFiTEST INTRO (Z503L)
Remote control with measurement key (Z550A), optional
accessory
Measurements per DIN EN 61010-031 may only be performed in
environments in accordance with measuring categories III and IV
with the safety cap attached to the test probe at the end of the
measurement cable.
In order to establish contact inside 4 mm jacks, the safety caps
have to be removed by prying open the snap fastener with a
pointed object (e.g. the other test probe).
See also section 17.1, “Technical Data for Measurement Cables
and Adapters”, beginning on page 52.
2.2 Overview of Included Features
1The so-called live measurement is only advisable if there is no bias current within
the system. Only suitable for motor protection switches with small nominal current
values.
2Currently available languages: D, GB, I, F, E, P, NL, S, N, FIN, CZ, PL
PROFITEST INTRO (M520T)
Testing of residual current devices (RCDs)
UB measurement without tripping the RCD
Tripping time measurement
Measurement of tripping current IF
Selective, SRCDs, PRCDs, type G/R
AC/DC sensitive RCDs, types B and B+, EV, MI
Testing for N-PE reversal
Measurement of loop impedance ZL-PE / ZL-N
Fuse table for systems without RCDs
Without tripping the RCD, fuse table
With 15 mA test current1, without tripping the RCD
Earth resistance RE (mains operation)
Measurement of equipotential bonding RLO
Automatic polarity reversal
Insulation resistance RINS
Variable or rising test voltage (ramp)
Voltage UL-N / UL-PE / UN-PE / f
Special measurements
Phase sequence
Earth leakage resistance RE(INS)
Voltage drop (ΔU)
Features
Selectable user interface language 2
Memory (database for up to 50,000 objects)
RS 232 port for RFID/barcode reader
USB port for data transmission
ETC user PC software
Measuring category: CAT III 600 V / CAT IV 300 V
Factory calibration certificate
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gossen Metrawatt Profitest Intro wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info