GB
Application
Can be used in conjunction with:
Pressurised storage heaters
Thermally controlled instantaneous heaters
Hydraulically controlled instantaneous heaters
Operation with unpressurised storage heaters (= open water
heaters) is not possible.
Technical data
Flow pressure
- min. 0.5 bar
- recommended 1 - 5 bar
Operating pressure max. 10 bar
Test pressure 16 bar
A pressure reducing valve must be fitted in the supply line if
static pressures exceed 5 bar to satisfy noise level ratings.
Avoid major pressure differences between hot and cold water
supply.
Flow rate at 3 bar flow pressure: approx. 27 l/min
Temperature
Hot water inlet: max. 80 °C
Recommended (energy saving): 60 °C
Scalding protection possible by fitting a temperature limiter
(see Replacement parts, fold-out page II, Prod. no.: 46 375).
Water connection hot - left
cold - right
Note (29 067):
This fitting can be combined with head and hand shower sets
by using a 3-way diverter.
Important note:
Never install shut-off valves in the outlet pipe (mixed
water) downstream of any built-in mixer.
Installation
Prepare the wall for the installation.
Prepare the holes for the single lever mixer and slots for the
pipes.
Align single lever mixer using fitting template and fit,
see fold-out page I, Figs. [1] and [2].
Permissible tolerances are given on the dimensional
drawing.
The arrow on the fitting template must point upwards.
To align place a spirit level on the cam on the fitting
template (A), see Fig. [1].
The finished surface of the wall (B) must lie within the
area (X) of the fitting template, see Fig. [2].
The cold water supply must be connected on the right, hot
water supply on the left.
Connect pipes.
Open cold and hot-water supply and check connections
for water-tightness.
Flush piping system prior and after installation of fitting
thoroughly (Consider EN 806)!
Plaster and tile the wall.
Do not remove the fitting template before final installation.
Final installation
Remove fitting template.
Note:
First fit the diverter (D) if installing trim set 29 061, see fold-out
page I, Fig. [3].
1. Remove screw plug (E).
2. Screw diverter (D) into position using 17mm socket spanner
and tighten.
Flow rate limiter
This mixer is fitted with a flow rate limiter, permitting an
infinitely variable individual reduction in flow rate. The highest
possible flow rate is set at the factory before despatch.
The use of flow rate limiters in combination with hydraulic
instantaneous heaters is not recommended.
To activate, see Fig. [4].
Install escutcheon and lever, see Figs. [5] and [6].
If the escutcheon can not be pushed far enough onto the cap,
an extension (see replacement parts, fold-out page II,
Prod. no.: 46 807 = 25mm / 46 808 = 50mm) must also be
installed.
Additionally seal the top edge of the escutcheon with silicone
when fitting against a particularly rough surface (deep tile
joints, highly textured tile).
Check mixer for correct operation, see fold-out page III,
Fig. [7].
Function of automatic diverter (D), see Fig. [8].
Pulling the lever will release water delivery.
On the bath mixer, water will always emerge from the lower
outlet first (e.g. bath outlet).
Pressing diverter (D) shuts off the flow of water to the bath and
delivers water to the shower outlet.
When the mixer is closed, the diverter is released
automatically so that when the mixer is opened again, water
will always emerge from the lower outlet first (e.g. bath outlet).
Maintenance
Inspect and clean all parts, replace as necessary and lubricate
with special grease.
Shut off hot and cold water supply.
I. Replacing the cartridge (F), see fold-out page III, Figs. [9]
to [11].
Observe the correct installation position!
Ensure that the cartridge seals engage in the grooves of the
housing. Fit screws (G) and tighten evenly and alternately.
II. Diverter (D), see fold-out page III, Figs. [9] to [11].
Replacement parts, see fold-out page II (* = special
accessories).
Care
For directions on the care of this fitting, refer to the
accompanying Care Instructions.
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Grohe 29067 BauMetric wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info