Floor protection
The floor is to be protected from the radiant heat from
the area of the viewing window (combustion chamber).
In addition, for practical reasons associated with
cleaning it is recommended that you install your pellet
stove on a fireproof base that extends beyond the device
at the back and on the sides by at least 5 cm and at the
front by at least 50 cm. We have floor protection plates
(underlay plates or U plates) in our range of accessories.
If required, you may order them from your specialist
stove dealer. As an alternative, a tile or stone floor is of
course very suitable.
Safety gaps (minimum gaps):
During installation of the stove it is absolutely essential
to observe the official fire protection regulations. Ask
your district heating inspector about this.
The following must be maintained as the minimum
distances from flammable or temperature-sensitive
materials (e.g. furniture, wallpaper, wooden cladding)
and from loadbearing walls. (See drawing):
A 10 cm from the back wall
B 15 cm from the side walls and
C 80 cm in the direction of radiation.
Figure 2: Safety gaps
The chimney (fireplace or flue) must for example be
made of stainless steel or ceramics (glazed internally) so
that it cannot rot. This is necessary because of the low
temperature of flue gases from your pellet stove.
Standard trade flue tubes may be used for the
connection to the fireplace. Approved Flex steel flues
are also suitable.
Since excess pressure may build up at the smoke outlet
because of the way that the pellet stove works with an
induced draught fan, all fume outlet pipes as far as the
intake to the fireplace must be gas-tight. It is also
essential to ensure that the flue tube does not stick out
into the open cross-section of the chimney. The use of
wall lagging is recommended for the insertion into the
chimney. (See Figure 3).
With longer flue gas pipework, horizontal sections and
constrictions must be avoided and specially insulated
flue tubes should be used. Pipework rising in the
direction of the chimney is recommended.
Figure 3: Chimney connection
1 = Wall lagging
2 = Gas-tight pipework
3 = Underlay plate
External air intake:
In airtight buildings, whilst the pellet stove is operating, a
reduction in the oxygen level in the room where the
stove is installed may occur, so adequate ventilation
must be ensured. For this the pellet stove offers you the
option of operating independently of the air in the room.
To do this, connect the air intake elbow located on the
back (diameter: 57 mm) to a hose or a similar suitable
air duct. The end of the air duct must be located in the
open air or in a well-ventilated room within the building.
When installing the pellet stove in combination with
controlled residential room ventilation, the end of the air
intake duct must not be connected to the ventilation
system in an adjacent room with the air connection
system. To ensure sufficient volume of air intake, the
pipe should not be longer than about 3 m and not have
too many bends. This pipe should have a minimum
diameter of 5 cm. (The bigger, the better). If the pipe
goes to the open air, it must end with a downward 90°
bend or with wind protection. (See Figure 4).
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Haas-Sohn PALLAZZA-II 519.08 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Haas-Sohn PALLAZZA-II 519.08

Haas-Sohn PALLAZZA-II 519.08 Bedienungsanleitung und Installationsanweisung - Deutsch - 34 seiten

Haas-Sohn PALLAZZA-II 519.08 Bedienungsanleitung - Französisch - 35 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info