Wiring Diagram: Low Voltage
When installing HE-304 Ceiling Modules in a existing lighting circuit,
conventional light switches should be disconnected and terminated as part of
the installation.
If your lighting circuits using ceiling roses, it is recommended that the current
wiring connections should be re-terminated using a suitable junction box.
Any existing switches currently controlling the light fitting should be
disconnected and suitably terminated.
The HomeEasy Ceiling Module is designed to be connected to the existing
permanently live lighting circuit between a convenient junction box and the
light fitting.
Any existing switches currently controlling the light fitting should be
disconnected and appropriately terminated.
Lighting circuits supplying Ceiling Receivers should always be protected by a 5
Amp rewire-able fuse or equivalent Miniature Circuit Breaker (MCB) located
within the Consumer Unit. Under no circumstances should any protection
devices with higher ratings be used.
** Ceiling Modules, are not designed to be used with loop-in/loop-out wiring, a
suitable junction box needs to be used if its necessary to connect the supply to
further fittings, the unit is designed for permanent installation.
The HE-304 Ceiling Modules are designed to be mounted inside a suitable
enclosed housing, which are dry and adequately ventilated (indoor use).
For outdoor use a suitable IP56 enclosure must be used. The ceiling receiver
module is designed to be maintenance free, but where possible access should
be available when needed.
Instalation Notes:
* All Earth conductors must be suitably sleeved with Green/Yellow
* Ensure that all bare conductor
ends are fully inserted into each
terminal, that all terminal
Standard Ceiling Rose
Standard Ceiling Rose
240V Mains Ring
** Ceiling Module
Earth
Connection to
Standard Light
Connection to
Standard Light
Sutiable Junction Box
Earth Sleaving Must Be Used
Neutral
Live
Earth
Wiring Diagram: Standard Installation
WARNING: Before installing the HomeEasy Ceiling Modules, isolate the circuit at the fuse/MCB board.
Connect the supply Live and Neutral conductors to the HomeEasy Receiver terminals marked L and N SUPPLY.
Connect the cable from the light fitting to theHomeEasy Receiver terminals marked L(Load) and N(Neutral).
For earth continuity the supply and load Earth conductors must be terminated externally using a sutiably insulated terminal block.
Standard Ceiling
Standard Ceiling
240V Mains Ring
** Ceiling Module
Earth Connection
Connection to
Low Voltage Light Fitting
Sutiable Junction Box
Earth Sleaving Must Be Used
Neutral
Live
Earth
Manufacturer
Specified
Transformer
Manufacturer
Specified
Transformer
* All Earth conductors must be suitably sleeved with Green/Yellow
If in any doubt consult a qualified Electrician
L
N
N
L
N
N
Neutral
Neutral
Load Live
Live
L
N
N
L
N
N
Neutral
Neutral
Load Live
Live
Connection to
Low Voltage Light Fitting
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Home Easy HE-304 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info