PO
SAVE THESE INSTRUCTIONS
(119PO) ULTRA XTR™ RECTANGULAR / PRISM FRAME™ POOLS ENGLISH 7.5” X 10.3” PANTONE 295U 11/07/2018
English
Page 5
Barriers for Residential Swimming Pool Guidelines:
Anoutdoorswimmingpool,includinganinground,aboveground,orongroundpool,hottub,orspa,shouldbe
providedwithabarrierwhichcomplieswiththefollowing:
1.
Thetopofthebarriershouldbeatleast48inchesabovegrademeasuredonthesideofthebarrierwhich
facesawayfromtheswimmingpool.Themaximumverticalclearancebetweengradeandthebottomof
the barrier should be 4 inches measured on the side of the barrier which faces away from the swimming
pool.Wherethetopofthepoolstructureisabovegrade,suchasanabovegroundpool,thebarriermay
beatgroundlevel,suchasthepoolstructure,ormountedontopofthepoolstructure.Wherethebarrieris
mountedontopofthepoolstructure,themaximumverticalclearancebetweenthetopofthepoolstructure
and the bottom of the barrier should be 4 inches.
2.
Openings in the barrier should not allow passage of a 4-inch diameter sphere.
3.
Solidbarriers,whichdonothaveopenings,suchasamasonryorstonewall,shouldnotcontain
indentations or protrusions except for normal construction tolerances and tooled masonry joints.
4.
Wherethebarrieriscomposedofhorizontalandverticalmembersandthedistancebetweenthetopsofthe
horizontalmembersislessthan45inches,thehorizontalmembersshouldbelocatedontheswimmingpool
sideofthefence.Spacingbetweenverticalmembersshouldnotexceed1-3/4inchesinwidth.Wherethere
aredecorativecutouts,spacingwithinthecutoutsshouldnotexceed1-3/4inchesinwidth.
5.
Wherethebarrieriscomposedofhorizontalandverticalmembersandthedistancebetweenthetops
ofthehorizontalmembersis45inchesormore,spacingbetweenverticalmembersshouldnotexceed
4inches.Wheretherearedecorativecutouts,spacingwithinthecutoutsshouldnotexceed1-3/4inchesin
width.
6.
Maximummeshsizeforchainlinkfencesshouldnotexceed
1-1/4
inchsquareunlessthefenceisprovided
withslatsfastenedatthetoporthebottomwhichreducetheopeningstonomorethan1-3/4inches.
7.
Wherethebarrieriscomposedofdiagonalmembers,suchasalatticefence,themaximumopeningformed
bythediagonalmembersshouldbenomorethan1-3/4inches.
8.
AccessgatestothepoolshouldcomplywithSectionI,Paragraphs1through7,andshouldbeequipped
toaccommodatealockingdevice.Pedestrianaccessgatesshouldopenoutward,awayfromthepool,and
shouldbeself-closingandhaveaselflatchingdevice.Gatesotherthanpedestrianaccessgatesshould
haveaself-latchingdevice.Wherethereleasemechanismoftheself-latchingdeviceislocatedlessthan
54inchesfromthebottomofthegate,(a)thereleasemechanismshouldbelocatedonthepoolsideofthe
gateatleast3inchesbelowthetopofthegateand(b)thegateandbarriershouldhavenoopeninggreater
than 1/2 inch within 18 inches of the release mechanism.
9.
Whereawallofadwellingservesaspartofthebarrier,oneofthefollowingshouldapply:
(a) All doors with direct access to the pool through that wall should be equipped with an alarm which
produces an audible warning when the door and its screen, if present, are opened. The alarm should
soundcontinuouslyforaminimumof30secondswithin7secondsafterthedoorisopened.Alarms
shouldmeettherequirementsofUL2017General-PurposeSignalingDevicesandSystems,
Section77.Thealarmshouldhaveaminimumsoundpressureratingof85dBAat10feetandthe
soundofthealarmshouldbedistinctivefromotherhouseholdsounds,suchassmokealarms,
telephones, and door bells. The alarm should automatically reset under all conditions. The alarm should
beequippedwithmanualmeans,suchastouchpadsorswitches,totemporarilydeactivatethealarm
forasingleopeningofthedoorfromeitherdirection.Suchdeactivationshouldlastfornomorethan
15seconds.Thedeactivationtouchpadsorswitchesshouldbelocatedatleast54inchesabovethe
threshold of the door.
(b)
ThepoolshouldbeequippedwithapowersafetycoverwhichcomplieswithASTMF1346-91listed
below.
(c)
Othermeansofprotection,suchasself-closingdoorswithself-latchingdevices,areacceptablesolong
asthedegreeofprotectionaffordedisnotlessthantheprotectionaffordedby(a)or(b)described
above.
10.
Whereanabovegroundpoolstructureisusedasabarrierorwherethebarrierismountedontopofthe
poolstructure,andthemeansofaccessisaladderorsteps,then(a)theladdertothepoolorsteps
shouldbecapableofbeingsecured,lockedorremovedtopreventaccess,or(b)theladderorsteps
shouldbesurroundedbyabarrier.Whentheladderorstepsaresecured,locked,orremoved,any
opening created should not allow the passage of a 4-inch diameter sphere.
Barriers should be located so as to prohibit permanent structures, equipment or similar objects from being
used to climb the barriers.
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Intex 26797 Prism Frame wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Intex 26797 Prism Frame

Intex 26797 Prism Frame Bedienungsanleitung - Deutsch - 15 seiten

Intex 26797 Prism Frame Bedienungsanleitung - Holländisch - 16 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info