AS-80 access system control unit MKM51600
1
The AS-80 access system control unit
The AS-80 access control system can operate electric devices such as
door locks, gates or security systems. It consists of two parts - a JA-80H
keypad and/or JA-80N RFID card reader (delivered separately) and the
AS-80 control unit with built-in backup power. One or two keypads can
be wired to each control unit (e.g. they can be installed on both sides of
a single door).
A separate control unit with a built-in backup power supply placed in a
protected (indoor) area insures maximum security.
Communication via the cable from the keypad to the control unit is
encrypted with a sophisticated code protocol. This ensures that there is
no other way to operate the device than by entering a valid access code.
The system can handle 120 user codes and RFID cards. An exit button
can be used for easy door opening from inside.
The keypad itself is made of solid plastic, has a backlight for easy
operation and it is suitable for vandal-proof outdoor applications.
Installation
Installation shall only be undertaken by technicians holding a certificate
issued by an authorized distributor.
Up to 2 keypads / readers (JA-80N/H) can be connected to the AS-80
unit. The first keypad must be set as a master and all programming can
only be done using the master keypad. The second (slave) controller
can be a keypad or an RFID reader.
A keypad or reader can be installed outdoors (IP-65).
1. remove the front panel - unscrew the back-housing screw
2. fix the bottom housing onto the desired place (check that the tamper spring
is properly pushed down).
3. connect the keypad’s cable to the control unit’s AS-80 terminals using
8-wire shielded cable, max. length 150 m
4. put the front panel back and fix it using the screw
5. fix the AS-80 unit onto the desired place
6. connect the cable in the AS-80 unit according to the description below
Note, if you change a master keypad, you must set the system up again!
If a second keypad is used then it should be placed at least 50cm from
the master keypad.
Control unit terminal descriptions:
C1, NC1, NO1 relay switch-over contact, max.1.5 A / 24 V
C2, NC2, NO2 relay switch-over contact, max.1.5 A / 24 V
TMP, TMP NC tamper output, max. 0.1 A / 25 V;
IN, COM Exit button switch input
Connection of the keypad / reader to the AS-80 unit
Keypad wire terminal in the control unit
Red + 12V
Blue GND
Green CLK
Brown DTA
Yellow not connected (used for entering setting mode, it
should be isolated after installation)
Pink not connected
Grey, White TMP
LED indicators on the control unit:
Red 1 ON=output relay 1 is triggered
Red 2 ON=output relay 2 is triggered
Green ON=Power on
LED indicators on the keypad:
Status Open System
Red Green - User mode
Green Green - Service mode
Red Green - The relay is switched on (door is
open)
Red Green - Waiting for confirmation by a
flashing code/RFID card
- - Orange Master and Installer codes are
not programmed
First powering-up
1. Set the keypad’s/reader’s operation mode. The first keypad (or if
only one keypad will be used in the system) must be set as a master. A
second keypad/reader can be added to the system at any time and must
be set as a slave.
To open setting mode:
1. Disconnect the power
2. Disconnect the DTA (Brown) and connect it to the yellow wire
3. Restore the power (the keypad starts continuously sounding)
4. Disconnect the Brown and Yellow wires
To set the JA-80H keypad as a master:
press 0 and when the keypad beeps press 4
To set the keypad / reader as a slave:
If you have a JA-80H keypad, press 0 and when the keypad beeps
press 0 again
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Jablotron AS-80 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info