Bezdrátový akustický detektor rozbití skla JA-60B 2/2 MEY51012
JA-60B WIRELESS GLASS BREAK DETECTOR
The JA-60B is a modern wireless glass break detector that provides
easy and reliable protection against robbery. It ensures extremely high
reliability and false alarm immunity. One sensor covers an entire room,
regardless of the number of windows. A dual technology detection method
(air pressure and sound analysis) is combined with digital processing to
guarantee high sensitivity to the breaking of glass.
A special testing mode enables simple adjustments to the detector.
Regular self testing is performed and the final result is transmitted to a
control panel. Digital hopping code radio communication guarantees highly
secure data transmission. The detector is also protected against
tampering.
Specification:
Detection method acoustic signal analysis
Power voltage 3 V (2x alkaline AAA batteries)
Battery life time typically 1 year
Detection range max. 9 m
Working freguency 433,92 MHz
Communication distance (open air) up to 100 m
Complies with EN 50131-1 grade 2
Environmental class II indoor general, -10 to +40°C
Can be operated according to ERC REC 70-03
Contents of JA-60B set: detector, 2 dowels, 2 screws, 2x AAA batteries
Hereby, Jablotron Ltd., declares that this JA-60B is in compliance
with the essential requirements and other relevant provisions of
Directive 1999/5/EC.
Original of the conformity assessment can be found at the web page
www.jablotron.cz, section Technical support.
Installation
The JA-60B can detect the breaking of glass that is part of the
peripheral walls of the protected area. The glass must be fixed in a
frame and its minimum size must be 0.6 x 0.6 m. The distance
between the detector and the glass should not exceed 9 meters. The
JA-60B can be mounted on a wall or a ceiling. The unit must have an
unobstructed view of the protected glass (in the case of heavy curtains,
mount the unit on the widow frame behind the curtains). The detector
should not be installed close to any metal surfaces or other objects
obstructing radio signal transmission.
Installation procedure:
Open the detector cover by pressing the internal tab.
Attach the detector to the wall or ceiling using the 2 provided screws.
The antenna should be vertical (pointing up or down).
The INS/DEL jumper should be closed if you want the system to react
immediately. Opening the jumper will select for a delayed reaction.
Do not install JA-60B closer than 0.5 m to other wireless detectors.
Enrollment of the detector to the system
Study the installation manual of the receiver unit (control panel) to
learn how to enter the enrolling mode to enroll the detector.
Install the two provided AAA batteries into the detector (polarity is
marked in the detector) and leave it uncovered.
The detector will generate an enrollment signal after the batteries
are installed.
The detector needs about 60 sec. to be ready to recognize glass
breaking after battery installation. This period is indicated with
steady light of the red LED.
Detector testing
Attach the detector’s cover. From this moment the detector will be in
a testing mode for 5 minutes and each triggering will be indicated by
the detector’s LED.
Strike carefully the protected glass with a cushioned instrument.
If the red LED on the detector responds with a short flash, then the
low frequency sensitivity is suitable.
Test the detector’s reaction on all protected glass surfaces.
If the sensitivity is too low, adjust it with the variable resistor
(clockwise direction for higher sensitivity and conversely)
For complete function testing, you can use a suitable glass break
simulator (recommended model GBT-201)
When detecting breaking glass the red LED will light for a longer
period and an alarm message will be transmitted to the receiver.
Five minutes after the cover was attached, the detector will
automatically enter the normal mode and its LED indicator will be
switched off (battery energy saving function). Open and close the
detector‘s cover to reset the testing mode for an additional 5 minutes
if needed.
Notes:
Do not set the sensitivity too high. The device should detect only
intensive strikes.
For maximum protection against false alarms, try to activate any device
in the area that may automatically cycle such as pumps, generators,
heating/air-conditioning, etc. If the cycling device triggers an alarm, mount
the unit in a different location.
Battery testing and replacement
The detector automatically checks the condition of its batteries. If it is
necessary to replace the batteries, the detector will inform the system.
While in a low battery mode, the detector works as normal, but each
low frequency activation is indicated with a flash of the LED. If a low
battery is indicated, it should be replaced as soon as possible (in a
week).
Before the batteries are replaced, the receiver (control panel) must
be put into the mode which allows for the opening of the detector (User
or Programming mode).
Use only high quality alkaline AAA batteries for replacement. After
you remove old batteries, wait 30 sec. before you install new ones.
Possible problems
No reaction after inserting batteries – remove the batteries and check
if they were inserted with the correct polarity, check their voltage
False alarms – some devices can generate frequencies that are similar
to the spectrum of breaking glass. (See paragraph Detector testing)
False alarms occurs when entering the premises - certain noises
(e.g. squeaking doors) can activate the detector – open the jumper
inside to set the JA-60B for delayed reaction
Unstable radio communication – ensure that there isn’t any metal
barrier between the detector and the receiver (control panel) and that the
detector’s antenna is positioned in parallel to the control panel’s antenna
(but they should not be in one line).
Note: Dispose of batteries safely depending on the type of the batteries
and local regulation. Although this product does not contain any harmful
materials we suggest you to return the product to the dealer or directly to
the producer after usage.
Internet: www.jablotron.cz
Tel.: +420 483 559 999
fax: +420 483 559 993
Po d Skalko u 3 3
466 01 Jablonec nad Nisou
Czech Republic
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Jablotron JA-60B wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info