The JA-63E wired keypad 2 / 2 MKP51001
The JA-63E digital bus wired keypad
The JA-63E keypad is designed to control and program alarm systems of
Jablotron’s JA-6x series. The keypad is equipped with backlit keys, built-in LED
signalling, acoustic signalling, and a display. It conveys information about the
system status in a convenient way. The keypad communicates via the control
panel digital bus. You can connect the keypad to the control panel via an RJ
cable or via a standard communication cable connected to terminals. Multiple
JA-63E keypads can be connected to a single control panel.
Any undesirable mishandling of the keypad (like opening its housing or tea-
ring the keypad off its position) will trigger tamper signalling. In addition, the
number of attempts to enter an access code is checked not to exceed a given
limit.
Installation
Select the desired keypad location close to the building’s entrance.
1. Open the keypad’s rear housing (by pressing the two tabs on the left or
right side).
2. Route all required cables through the hole in the rear housing and install
the housing to the desired location.
3. Connect the digital bus cable either to the terminal board or to an RJ
connector.
4. Close the keypad’s housing (attach the front housing on one side and
push it on the other side).
5. Switching on the control panel power makes the keypad ready for op-
eration.
Tabs
Tabs
SYSTEM 6 0
Installation notes:
Multiple JA-63E keypads in the system must be wired in parallel. Inlet
cables can be split directly in the control panel, in a converter, in the keypad or
in a junction box. RJ cable connection and connection to terminals can be
used in combination.
A connecting cable must be wired so that the corresponding positions
(terminals) are connected. When you use a self-made RJ cable, be careful to
connect identically coloured wire ends to identically marked positions (termi-
nals).
If the keypad does not function after being connected, disconnect the
inlet cable and check if the corresponding positions (terminals) in the control
panel and the keypad are connected.
Operation
The keypad can operate and program the system to the full extent as it is
described in the control panel manual.
The following table describes the meaning of symbols on the keypad LED
indicators:
Alarm
Power supply
Tamper
Set (Armed)
Fault
Battery
Wireless communication indication
Functions F1 through F0 can be used as described in the control panel ma-
nual. Besides this, there are 4 extra keys with the following functions:
Setting (Arm-
ing)
(equal to F1
entry)
Door opening
(equal to F3 entry)
Partial setting
(equal to F2
entry)
Panic (access under
duress)
(equal to F7, before
access code entry)
Remote system access
The JA-63E keypad allows you to remotely operate or program a JA-6x
system via a phone line using a JA-60U modem. Such operation requires the
system to be equipped with a telephone communicator with the remote access
feature enabled (see the security system installation manual).
Note: Remote system access via the JA-63E keypad is only possible using a
JA-60U modem of DY62012 version or higher.
Connecting remotely to the system: Connect the JA-60U modem to the
phone line. Connect the JA-63E keypad cable to the modem’s data connector.
After powering up the modem, the keypad will show a u on the display to
indicate that it is ready to establish a connection.
The initial connection is established by keying in:
xxxxxxxx F1 y F2 ttt...t F3 nnn...n F d
where:
xxxxxxxx is an 8-digit access code for system remote access
y answering machine bypass (a so-called second call) 0-
not bypassed, 1-bypassed
ttt...t call back tel. number – if call back is not requested just
enter F3 after F2
nnn...n the remote system tel. number (a pause can be specified
by keying in F0)
d dialling method: 4-tone, 5-pulse
After the d parameter is entered, the modem will establish a connection
and the keypad will display the remote system status. The keypad then beha-
ves the same way as if it had been connected directly to the system. Depen-
ding on the quality, the telephone line might be slower in its response. A JA-
63 remote connection disables the 4 big keys on the keypad’s right side. Use
keys F0 to F9 instead.
The connection is terminated by pressing key .
A re-connection (using the same modem) is established by entering F6. The
connection parameters are memorized.
If you perform a call to a control panel which has the same access code
but a different telephone number, you do not need to re-enter the whole con-
necting sequence. Instead, it is sufficient to key in nnn...n F4 – i.e. the control
panel tel. number followed by one of the F4/F5 keys (depending on the
tone/pulse dialling method).
Technical specifications
Connection with a cable to the JA-6x digital bus connector
Connecting cable 4 core cable with RJ connectors (4/4 1:1) or
ordinary telephone cable (terminals)
Length of the inlet cable max. 100 m when a paired cable is used
Power supply 10 –14 V (taken from the digital bus)
Power consumption 25mA
Enclosure IP40
Dimensions 125 x 145 x 30 mm
Complies with EN 50131-1, EN 50131-3 grade 2
Environmental class II indoor general -10 to +40°C
EMC EN 50130-4,EN 55022
Contents of the kit: JA-63E keypad, 4 m of connecting cable,
4 rawl plugs, 4 screws, 2 RJ-44 connectors.
Accessories – for keypad connection (can be ordered separately):
RJ-40 converter from RJ connector to 4 terminals
RJ-21 RJ connector splitter (2/1)
RJ-44 cable connector (4P/4C)
RJ-00 crimping tool for RJ connectors
CT-04 cable for RJ connectors
JABLOTRON ALARMS a.s hereby declares that the JA-63E is in compliance
with the essential requirements and other relevant provisions of Directive
2004/108/EC. The original of the conformity assessment can be found at
www.jablotron.com
, Technical Support section.
Note: Although this product does not
contain any harmful materials we
suggest you return the product to the
dealer or directly to the producer after
use. See www.jablotron.com for details.

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Jablotron JA-63E wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info