554836
19
Zoom out
Zoom in
Vorherige Seite
1/22
Nächste Seite
fig. 18 continues
Function Sequence Options
Factory
default
Setting to
comply with
EN-50131-1
Notes
Device reactions and section assignment
(detectors, key fobs, control panel and
keypad inputs)
A detector’s natural reaction can be INS,
DEL or Fire (selectable in the detector)
The natural reaction of Control panel &
Keypad wired inputs is DEL
Keyfob natural reactions: (or ) = SET
(arm), (or ) = UNSET (disarm) and both
simultaneously = Panic. If a reaction from 2 to
8 is selected (see opposite), only the key
(or ) and double buttons + ( + )
will have it. The ( ) button has no effect
(can still be used for controlling UC/AC
receivers).
Assignment to sections will only have an
effect on partial arming or if the system is
split (except PG output control)
For partial arming, a pair of keyfob
buttons assigned to section:
A has the effect:
(or ) = SET A, (or ) = SET AB
B has the effect:
(or ) = SET A, (or ) = SET AB
C has the effect:
(or ) = SET ABC, (or ) = UNSET A
In
BC
paira split system, a keyfob button
assigned to section: A=SET/UNSET A, B
=SET/UNSET B, C =SET/UNSET ABC
61
nn r s
Code (card) reactions and section
assignment
A code (card) may have the same kind of
reaction as devices
Assignment of the c
u
ode to sections is
ill
seful for split systems only. In a split
system, a code (card) assigned to C w
SET/UNSET all ABC sections.
62
nn r s
nn = address 01 to 50
r = reaction:
0 disabled (incl. tamper
sensor)
1 Natural – this means:
for detectors = selected by
DIP switch in the detector,
for wired inputs = DELay,
for Codes (cards) =
SET/UNSET
2 Panic
3 Fire
4 24 hours
5 Next DELay
6 INStant
7 SET (arm)
8 PG control (s: 1=PGX,
2=PGY,3=PGX+PGY)
9 SET/UNSET (toggle)
s = section 1=A, 2=B, 3=C -
has to be entered even if the
system is not split and setting
(arming)has no meaning.
all
Natural
in C
When the detector is disabled
(r=0), the tamper sensor is not
triggered,
Natural reaction of control panel
wired inputs (or IN keypad input)
is delayed (DEL)
Enrollment by keying in production codes
nn = address 01 to 50, xxxxxxxx = last 8 digits of the
60 nn
xxxxxx
xx
production code
(below the bar code on the device)
Automatic Daily Setting/Unsetting schedule
n = action sequence index
n
C
f unsplit then AB)
6
en ABC)
hh -
The scheduled actions will
(arming/disarming)
6
hh mm
4 n a
(0 to 9)
a = action:
0 no actio
1 SET ABC
2 UNSET AB
3 SET A
4 SET B (i
5 UNSET A
(if unsplit then ABC)
UNSET B
(if unsplit th
hours, mm - minutes
No action
happen ever
y day
Changing the service code
8080
5 NC
NC
NC = new code (4 digits) enter NC twice
Go to maintenance mode
ode
-
292
switches to maintenance m
Setting the internal clock 4 hh mm DD MM YY
00 :00
1.1.00
Editing keypad text
Text for device names, code names and PG
output names are stored in each individual
keypad.
The menu ca rvice
mode by holding the ? key. Then the
internal keypad menu will be displayed.
Using the arrows or keys 1 and 7 you can
scroll through the menu to Edit text.
Press Editing mode and the name of
the device enrolled to address 01 is then
displayed with a flashing cursor on the
first text character.
Key functions:
1 and 7 text scrolling (see table)
3 and 9 character-selection
(A,B,C,D.......8,9,0)
4 and 6 cursor control (left/right)
2 delete selected character
8 space
 exit editing (& save changes)
Device
Only capital letters can be entered this way. If
there are multiple keypads, each must be edited
individually this way or all of them can be easily
programmed via OLink software
n be entered in Se
JA-83K control panel installation manual - 19 - MKG51101
19

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Jablotron JA-83K wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info