555003
1
Zoom out
Zoom in
Vorherige Seite
1/2
Nächste Seite
Klávesnice KB-350 Antivandal 4 / 4 MEV51303 Klávesnice KB-350 Antivandal 1 / 4 MEV51303
Reset
If the master code or service code is forgotten or if you connect a new keypad, it is necessary to reset the
control unit. Disconnect power and connect the RESET jumper and after 20sec. reconnect power. After 5
seconds, disconnect the jumper. This procedure will restore the factory default settings (master code = 1234,
service code = 9999, all user codes are erased) and it will also enroll connected keypads to the control unit.
output control
PANIC mode
factory setting:
MC 1234
UC1-UC9 deleted
Code setting
setting deleting
save and exit
save and exit
MC master code
UC1-UC9 user codes
operating
mode
Parameters setting
Output N.1 mode
Output N.2 mode
Panic mode
Number of attempts
Tamper output reaction
New Service Code
values
default
00- latch
xx- pulse (01-99 sec)
0=off, 1=on
0=off, 1=on
1-9 or 0=unlimited
must be entered 2x
Note: Although this product does not contain any harmful materials we suggest you to return the product to
the dealer or directly to the producer after usage.
KB-350M Digital Access Keypad
The KB-350M access control keypad can operate electric devices such as door locks, gates, or security
systems. It consists of two parts - a keypad and a control unit. Both parts are connected by a two-core
cable. One or two keypads can be wired to each control unit (e.g. they can be installed on both sides of a
single door). While one keypad is being accessed, the second keypad is temporarily bypassed.
A separated control unit insures maximum security. The communication in the cable from the keypad to
the control unit is encrypted with a sophisticated floating code protocol. This ensures that there is no other
way to operate the device than by entering a valid access code.
The keypad itself is made of a solid alloy and it is suitable for vandal proof applications.
Specifications
Power 10 – 16 V AC or DC, 60mA no relay on, 120 mA both relays on
Keypad connecting cable 2 core cable, max. 100 m, arbitrary polarity
Output relay (output 1) over-switching contact 1 A / 60 V
Transistor output (output 2) switches to GND – max. current 1.5 A / 25 V
Tamper output max. 100 mA / 25 V (control unit, keypad and cable tamper protection)
Power output rectified voltage from PWR input terminals - max. 1.2 A for max. 5 sec
Access codes 4, 5 or 6 digits, 1 master + 9 user codes (each code can be addressed to output 1
or 2)
Output modes programmable duration of pulse (from 1 to 99 sec.) or latch mode
Number of attempts programmable
Security grade 3 midle to high risk (EN 50131-1)
Keypad working environment outdoor use (class III), -25 °C to 50 °C (EN 50131-1)
Enclosure IP52 (EN 60529), mech. resistance IK08 (EN 50102)
Control unit working envir. indoor – general (class II), -10 °C to +40 °C (EN 50131-1)
Complies with the essential requirements of: 89/336/EC EMC Directive - Protection concerning electromagnetic
compatibility when is used for its intended purpose. Original of the conformity assessment can be found
at the web page www.jablotron.cz, section Technical support.
Installation
Keypad can be installed on a standard electro installation box (screw spacing - 60 mm).
remove front panel - use the provided tool to unscrew the 4 screws
connect the keypad’s terminals with the control unit’s BUS terminals using two wires (twisted pair) (e.g.
SYKFY cable), max. distance – 100 m, arbitrary polarity
up to 2 keypads can be wired in parallel, the total length of all cables should not exceed 100 m
reattach the keypad after powering and testing (see bellow)
Note, if you change or add a keypad, you must reset the control unit!
Control unit can be installed directly on a wall or on an installation box. Terminal descriptions follow:
C, NC, NO over-switching relay contact (output N.1), max. 1 A / 60 V, (C=common, NC=normally closed,
NO=normally opened)
TMP, TMP NC tamper output, max. 0.1 A / 25 V; opens when a control unit is opened, if any keypad is
lost, if the connecting cable is cut or shortened or if a pre-programmed number of attempts to
enter the correct code is exceeded or if a panic sequence is entered (programmable)
OUT transistor output (output N.2), max. 1.5 A / 25 V. It switches to GND when activated.
+E rectified power voltage (from PWR input terminals). It can be used for the powering of an
electric door lock etc. Maximum permanent load is 0.25 A, short period load (max. 5 sec.) -
can be 1.2 A (for electric strike release). Note that a corresponding power supply must be
used to power the unit (RWR terminals).
GND ground terminal of internal power supply
BUS, BUS bus line terminals for keypad connection. Up to 2 keypads can be connected in parallel. Twist
pair (e.g. SYKFY) is recommended, max. length – 100 m. Polarity is arbitrary. The bus is used
for both powering the keypads and for data transfer (a highly secure floating code is used).
Note, if you change keypads, you must reset the control unit.
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Jablotron KB-350M wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info