A7 MIG Welder© Kemppi Oy 2018 1804
INTEGRATION GUIDE
3.3 Power source
Place the machine on a sturdy, level surface that is dry
and will not allow dust or other impurities to enter the
machine’s cooling air ow. Preferably, situate the machine
in a suitable carriage unit so that it is above oor level.
The surface inclination may not exceed 15
degrees.
Ensure the free circulation of cooling air. There
must be at least 20 cm of free space in front
of and behind the machine for cooling-air
circulation.
Protect the machine against heavy rain and direct
sunshine.
Do not operate the machine in the rain.
Never aim the spray of sparks from a grinding machine
toward the equipment.
The power plug
The power source comes without a plug for connection
to the electrical grid. Attach a plug suitable for your
power-supply standard to the power cable. Check the
connections, attach the plug to a socket, and switch the
electrical power on from the welding power source to
verify that the machine works properly.
Switch the machine o, and unplug it from the power
socket before continuing to further steps in the hardware
installation.
If local or national regulations specify that an
alternative power cable is required, the cable must be
replaced in conformity with the regulations. Connection
and installation of the power cable and plug should be
carried out only by a suitably qualied person.
Remove the machines left-hand cover plate to enable
attachment of an electrical cable. The power source unit
can be connected to a 400 V, 3~ power supply.
If changing the power cable, take the following facts
into consideration:
The cable enters the machine through the inlet
ring on the rear panel and is fastened in place
with a cable clamp (05).
The phase conductors of the cable are coupled to
connectors L1, L2, and L3.
The protective ground line, colored green and
yellow, is coupled to the marked connector.
If you are using ve-lead cable, do not connect
the neutral conductor.
05
*
L3
L2
L1
* In S-type cables there is a protective grounding conductor,
green-and-yellow striped.
3.4 Cooling unit
If you use a water-cooled welding torch, you need a
cooling unit installed as part of the welder system. Attach
the cooling unit to the power source. See the detailed
installation instructions in the operating manual delivered
with the cooling unit package.
The cooling hose connections are described in Subsection
3.8.5, “Cooling hoses.
The wire feeder has no connectors for cooling hoses.
Use a special adapter to connect the cooling hoses to the
welding torch cooling connectors.
3.5 Wire feeder
Use a two-part mounting bracket to mount the wire
feeder securely on the robot arm. Fasten the upper part of
the bracket to the bottom of the wire feeder and the lower
part to the robot arm. Finish the installation by putting the
bracket parts together and xing them in place with bolts.
See the illustrated instructions included in the product
delivery package.
Mounting brackets are available for the most commonly
used welding robots. See the complete list at
www.kemppi.com.
The wire feeder connections are described in Section 3.8,
“Interconnection cable set.
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Kemppi A7 MIG Welder 450 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info