TECHNICAL DATA
Hardware
Power supply Internal power supply unit (110–230 V, 50–60 Hz)
Power consumption 40 W
Environment Temperature range 5–40 °C; humidity 0–95 %; non-condensing
Housing Robust metal housing, 19“ 1U with removable mounting brackets, network connectors on the
front
Number of fans 3
Interfaces
ETH 4 individual 10 / 100 / 1000-Mbps Gigabit Ethernet ports (ETH 1 - ETH 4); 1x Gigabit Ethernet
port (ETH 5). Up to 4 ports can be switched as additional WAN ports with load balancing.
Ethernet ports can be electrically disabled within LCOS conguration.
USB USB 2.0 Hi-Speed host port for connecting USB printers (USB print server) or USB data media
(FAT le system); bi-directional data exchange is possible (max. 480 Mbps)
Serial Interface Serial conguration interface
WAN protocols
Ethernet PPPoE, Multi-PPPoE, ML-PPP, PPTP (PAC or PNS) and plain Ethernet (with or without DHCP),
VLAN, IP
Declaration of conformity
Hereby, LANCOM Systems declares that this device is in compliance with Directives 2014/30/EU and 2014/35/EU.
The full text of the EU declaration of conformity is available at the following internet address:
www.lancom-systems.com/ce/
Package content
Documentation Quick Reference Guide (DE, EN), Installation Guide (DE/EN)
Accessories 2 Ethernet cables, 3 m (kiwi colored connectors); 1 serial conguration cable 1.5 m;
1 IEC power cord 230 V (not for WW devices); 1 grounding screw
MOUNTING AND CONNECTING THE DEVICE
*) The additional power LED statuses are displayed in 5-seconds
rotation if the device is congured to be managed by the LANCOM
Management Cloud.
LANCOM, LANCOM Systems and LCOS are registered trademarks. All other names or descriptions used may be trademarks or registered
trademarks of their owners. Subject to change without notice. No liability for technical errors and/or omissions. 111748/0718
LANCOM ISG-1000
Quick Reference Guide
Cloud-ready
a
USB interface
You can use the USB interface to connect a USB printer or a USB
storage device.
b
Serial conguration interface
Use the included serial conguration cable to connect the serial
interface (COM) to the serial interface of the device you want to
use for conguring / monitoring.
c
SFP / TP Ethernet interfaces (combo ports)
Insert suitable SFP modules into the SFP ports. Choose cables com-
patible with the SFP modules and connect them as described in the
module’s documentation. SFP modules and cables are not included.
d
If desired, alternatively connect the ETH 1 - ETH 4 TP Ethernet inter-
faces to your PC or a LAN switch using one of the enclosed cables
with the kiwi-colored connectors.
e
TP Ethernet interface
Use one of the enclosed cables with the kiwi-colored connec-
tors to connect the interface ETH 5 to your PC or a LAN switch.
f
Reset button
Pressed up to 5 seconds: device restart
Pressed until rst ashing up of all LEDs:
conguration reset and device restart
g
Power connector and grounding point (device back side)
Supply power to the device via the power connector. Please
use the IEC power cable supplied (separately available for WW
devices).
Warning! High touch current.
Connect to earth before
connecting the power supply.
7
8
h
ATTENTION: High touch current possible! Connect to earth
before connecting the power supply. For this purpose, remove
the existing blind screw and use the enclosed grounding screw
instead.
4
Please observe the following when setting up the device
A The mains plug of the device must be freely accessible.
A For devices to be operated on the desktop, please attach the adhesive rubber
footpads.
A Do not rest any objects on top of the device and do not stack multiple devices.
A Keep the ventilation slots on the side of the device clear of obstruction.
A Mount the device into a 19” unit in a server cabinet using the provided screws and mounting brackets.
RESET
COMUSB
TEMP
POWER
ETH 5
ETH 3
ETH 4
ETH 1
ETH 2
LANCOM ISG-1000
a
b c d
e
c d f
RESET
COMUSB
TEMP
POWER
ETH 5
ETH 3
ETH 4
ETH 1
ETH 2
LANCOM ISG-1000
a
b c
ed d
e f
d ETH 1 - ETH 4 - TP (one green and orange LED each)
Both LEDs off No networking device attached
Green, permanently Connection to network device operational,
no data trafc
Green, ickering Data transmission
Orange off 1000 Mbps
Orange, permanently 10 / 100 Mbps
b TEMP
Green, permanently CPU temperature OK
Red, blinking Hardware failure of the fan or CPU
temperature too high; additional acoustic
signal
e ETH 1 - ETH 4 - SFP (one green and orange LED each)
Both LEDs off No networking device attached
Green, permanently Connection to network device operational,
no data trafc
Green, ickering Data transmission
Orange off 1000 Mbps
Orange, permanently 10 / 100 Mbps
a POWER
Off Device switched off
Green, permanently* Device operational, resp. device paired /
claimed and LANCOM Management Cloud
(LMC) accessible
Green / red, blinking No password set. Without a password
the conguration data in the device is
unprotected.
Red, blinking Charge or time limit reached
1x green inverse
blinking*
Connection to the LMC active, pairing OK,
device not claimed
2x green inverse
blinking*
Pairing error, resp. LMC activation code
not available
3x green inverse
blinking*
LMC not accessible, resp. communication
error
c LCD display (rotating in two lines)
A Device name
A Firmware version
A Device temperature
A Date and time
A CPU load
A Memory usage
A Number of VPN tunnels)
A Data transfer in reception direction
A Data transfer in transmission direction
f ETH 5
Both LEDs off No networking device attached
Green, permanently Connection to network device operational,
no data trafc
Green, ickering Data transmission
Orange off 1000 Mbps
Orange, permanently 10 / 100 Mbps
This product contains separate open-source software components which are subject to their own licenses, in particular
the General Public License (GPL). The license information for the device rmware (LCOS) is available on the device‘s
WEBcong interface under “Extras > License information“. If the respective license demands, the source les for the
corresponding software components will be made available on a download server upon request.

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Lancom ISG-1000 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Lancom ISG-1000

Lancom ISG-1000 Kurzanleitung - Deutsch - 1 seiten

Lancom ISG-1000 Installationsanweisung - Deutsch - 17 seiten

Lancom ISG-1000 Installationsanweisung - Englisch - 17 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info