Zoom out
Zoom in
Vorherige Seite
1/29
Nächste Seite
LG Room
Air Conditioner
OWNER'S MANUAL
LG
MODELS: AS - W096_Series
W126_Series
C09AW_Series
C12AW_Series
C18AW_Series
C24AW_Series
IMPORTANT
• Please read this owner's manual carefully and thoroughly
before installing and operating your room air conditioner.
• Please retain this owner's manual for future reference after
reading it thoroughly.
Prior to installation, this air-
conditioning unit must be
submitted for approval by the
utility service which provides
electricity (EN 61000-3 Norm).
website http://www.lgservice.com
ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH GREEK
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Inhalt der Seiten


  • Page 1

    website http://www.lgservice.com

    ITALIANO

    LG Room
    Air Conditioner
    OWNER'S MANUAL
    Prior to installation, this airconditioning unit must be
    submitted for approval by the
    utility service which provides
    electricity (EN 61000-3 Norm).

    ESPAÑOL

    MODELS: AS - W096_Series
    W126_Series
    C09AW_Series
    C12AW_Series
    C18AW_Series
    C24AW_Series

    ENGLISH

    LG

    FRANÇAIS
    DEUTSCH
    • Please read this owner's manual carefully and thoroughly
    before installing and operating your room air conditioner.
    • Please retain this owner's manual for future reference after
    reading it thoroughly.

    GREEK

    IMPORTANT



  • Page 2

    Room Air Conditioner Owner’s Manual

    TABLE OF CONTENTS
    Safety Precautions.........................3

    FOR YOUR RECORDS
    Write the model and serial numbers here:
    Model #

    Prior to Operation ..........................6

    Serial #
    You can find them on a label on the side of each unit.
    Dealer's Name

    Introduction ....................................7

    Electrical Safety .............................8

    Operating Instructions.................10

    Maintenance and Service ............24

    Date Purchased
    ■ Staple your receipt to this page in the event you need
    it to prove date of purchase or for warranty issues.

    READ THIS MANUAL
    Inside you will find many helpful hints on how to use
    and maintain your air conditioner properly. Just a little
    preventive care on your part can save you a great deal
    of time and money over the life of your air conditioner.
    You'll find many answers to common problems in the
    chart of troubleshooting tips. If you review our chart of
    Troubleshooting Tips first, you may not need to call
    for service at all.

    PRECAUTION
    • Contact the authorized service technician for
    repair or maintenance of this unit.
    • Contact the installer for installation of this unit.
    • The air conditioner is not intended for use by
    young children or invalids without supervision.
    • Young children should be supervised to ensure
    that they do not play with the air conditioner.
    • When the power cord is to be replaced,
    replacement work shall be performed by
    authorized personnel only using only genuine
    replacement parts.
    • Installation work must be performed in
    accordance with the National Electric Code by
    qualified and authorized personnel only.

    2 Room Air Conditioner



  • Page 3

    Safety Precautions

    Safety Precautions

    This symbol indicates the possibility of death or serious injury.
    This symbol indicates the possibility of injury or damage to properties only.
    ■ The meanings of the symbols used in this manual are as shown below.

    Be sure not to do.
    Be sure to follow the instruction.

    ■ Installation
    Always perform grounding.

    • Otherwise, it may cause
    electrical shock.

    Securely attach the
    electrical part cover to the
    indoor unit and the service
    panel to the outdoor unit.
    • If the electrical part cover of the
    indoor unit and the service
    panel of the outdoor unit are not
    attached securely, it could result
    in a fire or electric shock due to
    dust, water, etc.

    Ensure that an installation
    frame of the outdoor unit is
    not damaged due to use for
    a long time.
    • It may cause injury or an
    accident.

    Don’t use a power cord, a
    plug or a loose socket
    which is damaged.

    • Otherwise, it may cause a fire
    or electrical shock.

    Always install an air leakage
    breaker and a dedicated
    switching board.
    • No installation may cause a fire
    and electrical shock.

    Do not disassemble or
    repair the product
    randomly.
    • It will cause a fire or electrical
    shock.

    For installation of the product,
    always contact the service
    center or a professional
    installation agency.
    • Otherwise, it may cause a fire,
    electrical shock, explosion or
    injury.

    Do not keep or use
    flammable gases or
    combustibles near the air
    conditioner.
    • Otherwise, it may cause a fire
    or the failure of product.

    Do not install the product at
    a place that ther is concern
    of falling down.
    • Otherwise, it may result in
    personal injury.

    Use caution when
    unpacking and installing.
    • Sharp edges may cause injury.

    Owner's Manual 3

    ENGLISH

    To prevent the injury of the user or other people and property damage, the following instructions must be
    followed.
    ■ Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified
    by the following indications.



  • Page 4

    Safety Precautions

    ■ Operation
    Do not share the outlet with
    other appliances.

    Do not use the damaged
    power cord.

    • It will cause an electric shock or
    a fire due to heat generation.

    • Otherwise, it may cause a fire
    or electrical shock.

    Take care so that the power
    cord may not be pulled
    during operation.

    Unplug the unit if strange
    sounds, smell, or smoke
    comes from it.

    • Otherwise, it may cause a fire
    or electrical shock.

    Take the power plug out if
    necessary, holding the head
    of the plug and do not touch
    it with wet hands.

    • Otherwise, it may cause
    electrical shock or a fire.

    Do not use the power cord
    near the heating tools.

    • Otherwise, it may cause a fire
    or electrical shock.

    • Otherwise, it may cause a fire
    and electrical shock.

    Do not allow water to run
    into electrical parts.

    Hold the plug by the head
    when taking it out.

    • Otherwise, it may cause the
    failure of machine or electrical
    shock.

    • It may cause electric shock and
    damage.

    Ventilate the room well
    when using this appliance
    together with a stove, etc.

    When cleaning the unit, first
    make sure the power and
    breaker are turned off.

    • An oxygen shortage may occur.

    Do not step on the
    indoor/outdoor unit and do
    not put anything on it.
    • It may cause an injury through
    dropping of the unit or falling
    down.

    Take care so that children
    may not step on the outdoor
    unit.
    • Otherwise, children may be
    seriously injured due to falling
    down.

    4 Room Air Conditioner

    • Otherwise, it may cause
    electrical shock.

    Do not place a heavy object
    on the power cord.
    • Otherwise, it may cause a fire
    or electrical shock.

    Do not modify or extend the
    power cord randomly.
    • Otherwise, it may cause a fire
    or electrical shock.

    Keep the flames away.

    • Otherwise, it may cause a fire.

    Do not open the suction
    inlet of the indoor/outdoor
    unit during operation.
    • Otherwise, it may electrical
    shock and failure.

    Never touch the metal parts
    of the unit when removing
    the filter.
    • They are sharp and may cause
    injury.

    Turn off the main power
    switch when not using the
    product for a long time.
    • Otherwise, it may cause the
    failure of product or a fire.

    When the product is
    submerged into water, always
    contact the service center.
    • Otherwise, it may cause a fire
    or electrical shock.



  • Page 5

    Safety Precautions

    ■ Installation

    • Otherwise, it may cause water leakage.

    Always inspect gas leakage after the
    installation and repair of product.
    • Otherwise, it may cause the failure of product.

    Install the product so that the noise or hot
    wind from the outdoor unit may not cause
    any damage to the neighbors.
    • Otherwise, it may cause dispute with the
    neighbors.
    Keep level parallel in installing the product.

    • Otherwise, it may cause vibration or water
    leakage.

    ■ Operation
    Avoid excessive cooling and perform
    ventilation sometimes.

    • Otherwise, it may do harm to your health.

    When gas leaks, open the window for
    ventilation before operating the unit.

    • Otherwise, it may cause explosion, and a fire.

    Do not place obstacles around the flow inlet
    or outlet.

    • Otherwise, it may cause the failure of appliance or
    an accident.

    Do not insert the hands or bars through the
    air inlet or outlet during operation.

    • Otherwise, it may cause personal injury.

    Use a soft cloth to clean. Do not use wax,
    thinner, or a strong detergent.

    • The appearance of the air conditioner may
    deteriorate, change color, or develop surface
    flaws.

    Do not use an appliance for special
    purposes such as preserving animals
    vegetables, precision machine, or art
    articles.
    • Otherwise, it may damage your properties.

    Always insert the filter securely. Clean it
    every two weeks.

    • Operation without the filter will cause failure.

    Do not drink water coming out of the air
    conditioner.

    • Otherwise, it may cause stomachache.

    Owner's Manual 5

    ENGLISH

    Install the drain hose to ensure that drain
    can be securely done.



  • Page 6

    Prior to Operation

    Prior to Operation
    Preparing for Operation
    1. Contact an installation specialist for installation.
    2. Plug in the power plug properly.
    3. Use a dedicated circuit.
    4. Do not use an extension cord.
    5. Do not start/stop operation by plugging/unplugging the power cord.
    6. If the cord/plug is damaged, replace it with only an authorized replacement part.

    Usage
    1. Being exposed to direct airflow for a long time may be hazardous to your health. Do not expose
    occupants, pets, or plants to direct airflow for a long time.
    2. Due to the possibility of oxygen deficiency, ventilate the room when using the appliance together with
    stoves or other heating devices.
    3. Do not use this air conditioner for non-specified special purpose (e.g. preserving precision devices,
    food, pets, plants, or art objects). Such use may damage your properties.

    Cleaning and Maintenance
    1. Do not touch the metal parts of the unit when removing the filter. Injury can occur.
    2. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation,
    leading to electric shock.
    3. When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at a
    very high speed during operation. There is a possibility of injury if the unit’s power is triggered while
    cleaning inner parts of the unit.

    Service
    For repair and maintenance, contact your authorized service dealer.

    6 Room Air Conditioner



  • Page 7

    Introduction

    Introduction
    Symbols used in this Manual

    This symbol alerts you to hazards that may cause harm to the
    air conditioner.
    NOTICE

    This symbol indicates special notes.

    Features
    WARNING: This appliance should be installed in accordance with national wiring
    regulations. This guide acts as a guide to help to explain product features.

    Indoor

    Air Inlet
    NANO Plasma Filter

    Air Filter
    Air Discharge
    Front Panel
    Power Cord
    Signal Receptor
    Power button

    Outdoor
    Air Intake Vents
    Connecting
    Wires

    Piping

    Air Outlet Vents
    Base Plate

    Drain Hose

    Owner's Manual 7

    ENGLISH

    This symbol alerts you to the risk of electric shock.



  • Page 8

    Electrical Safety

    Electrical Safety
    WARNING: This appliance must be properly grounded.
    To minimize the risk of electric shock, you must alway plug into a grounded oulet.

    Preferred method

    Ensure proper ground
    exists before use

    WARNING: Do not cut or remove the grounding prong from the
    power plug.
    WARNING: Attaching the adapter ground terminal to the wall
    receptacle cover screw does not ground the appliance unless the
    cover screw is metal and not insulated, and the wall receptacle is
    grounded through the house wiring.
    WARNING: If you have any doubt whether the air conditioner is
    properly grounded, have the wall receptacle and circuit checked by
    a qualified electrician.

    8 Room Air Conditioner



  • Page 9

    Electrical Safety

    Temporary Use of an Adapter

    Temporary method
    Adapter Plug
    Metal Screw

    Receptacle Cover

    WARNING: Never use the appliance with a broken adapter.

    Temporary Use of an Extension Cord
    We strongly discourage the use of an extension cord due to potential safety hazards. For temporary
    situations, use only CSA certified and UL listed 3-wire grounded extension cords, rated 15 A, 125 V.

    Owner's Manual 9

    ENGLISH

    We strongly discourage the use of an adapter due to potential safety hazards. For temporary
    connections, use only a UL-listed adapter, available from most local hardware stores. Ensure that the
    large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection.
    To disconnect the power cord from the adapter, use one hand on each to avoid damaging the ground
    terminal. Avoid frequently unplugging the power cord as this can lead to eventual ground terminal
    damage.



  • Page 10

    Operating Instructions

    Operating Instructions
    Remote Controller
    1. Remove the battery cover by pulling it according to the arrow
    direction.
    2. Insert new batteries making sure that the (+) and (-) of battery are
    installed correctly.
    3. Reattach the cover by sliding it back into position.

    NOTICE Use 2 AAA(1.5volt) batteries.
    Do not use rechargeable batteries.

    Storage and Tips for using the Remote Controller
    • The remote controller may be stored by mounting
    it on a wall.

    • To operate the room air conditioner, aim the
    remote controller at the signal receptor.

    Signal Receptor
    Receives the signals from the remote control.(Signal receiving sound: two short beeps or one long beep.)

    Operation Indication Lamps
    On/Off

    : Lights up during the system operation.

    Sleep Mode

    : Lights up during Sleep Mode Auto operation.

    Timer

    : Lights up during Timer operation.

    Preheat Mode

    : Lights up during Defrost Mode or Hot
    Start operation (Heat pump model only)

    Display

    : Indicates the setting temperature.

    PLASMA Plasma
    Energy-Saving

    Operation
    indicator

    Cooling
    heating
    dehumidification

    Shape of
    display

    Setting
    temp.

    : Light up during PLASAM purification
    operation.(optional)

    Operation indicating
    lamps

    : Light up during Energy-Saving cooling mode operation. (optional)

    A.I operation mode
    Standard

    10 Room Air Conditioner

    Too hot

    Hot

    Comfortable

    Cold

    Jet
    Test
    Energy-saving
    Too cold (Cool, Heat) cooling mode operation



  • Page 11

    Operating Instructions

    Remote Control Operations
    The controls will look like the following.

    1. START/STOP BUTTON
    Operation starts when this button is pressed
    and stops when the button is pressed again.
    2. OPERATION MODE SELECTION BUTTON
    Used to select the operation mode.
    3. ROOM TEMPERATURE SETTING BUTTONS
    Used to select the room temperature.
    4. INDOOR FAN SPEED SELECTOR
    Used to select fan speed in four steps
    low, medium, high and CHAOS.

    5

    5. JET COOL / HEAT
    Used to start or stop the speed cooling or heating.
    (Speed cooling or heating operates super high fan
    speed in cooling or heating mode.)

    1

    6
    3

    6. CHAOS SWING BUTTON
    Used to stop or start louver movement and
    set the desired up/down airflow direction.

    10

    7. ON/OFF TIMER BUTTONS
    Used to set the time of starting and stopping operation.
    (See page 21)

    4
    2
    7
    11
    8
    13

    CANCEL
    ON

    OFF

    9
    12

    SET
    AUTO CLEAN

    15

    17

    8. TIME SETTING BUTTONS
    Used to adjust the time. (See page 21)

    14
    16

    9. TIMER SET/CANCEL BUTTON
    Used to set the timer when the desired time is obtained and
    to cancel the Timer operation. (See page 21)
    10. SLEEP MODE AUTO BUTTON
    Used to set Sleep Mode Auto operation.
    (See page 21)

    Flip-up door
    (opened)

    12. ROOM TEMPERATURE CHECKING BUTTON
    Used to check the room temperature.

    Operation Mode

    13. PLASMA(OPTIONAL)
    Used to start or stop the plasma-purification function.
    (See page 19)

    Cooling Operation
    Auto Operation or Auto Changeover

    14. HORIZONTAL AIRFLOW DIRECTION CONTROL
    BUTTON (NOT ON ALL MODELS)
    Used to set the desired horizontal airflow direction.
    (See page 22)

    Healthy Dehumidification Operation

    15. RESET BUTTON
    Used prior to resetting time or after replacing batteries.

    Heating Operation

    • Cooling Model(

    ), Heat Pump Model(

    11. ENERGY-SAVING COOLING MODE BUTTON
    (OPTIONAL)
    Used to set Energy-Save in cooling mode.

    )

    16. 2nd F BUTTON
    Used prior to using modes printed in blue at the bottom of
    buttons. (See page 20)
    17. AUTO CLEAN(OPTIONAL)
    Used to set Auto Clean mode.

    Owner's Manual 11

    ENGLISH

    Signal transmitter



  • Page 12

    Operating Instructions

    Cooling operation

    1

    Press the Start/Stop button.
    The unit will respond with
    a beep.

    2

    Open the door on the remote control.
    To select Cooling Operation or Healthy Dehumidification
    Operation.

    Cooling

    3
    ON

    Auto
    changeover

    Healthy
    Dehumidification

    Heating
    (Heat pump model only)

    Press the Jet Cool button to operate the speed cooling mode
    and the unit will operate in super high fan speed on cooling
    mode for 30 minutes.
    To raise the temperature

    To lower the temperature

    4

    To cancel the Jet Cool mode, press
    the Jet Cool button or the fan speed
    button or the room temperature setting
    button again and the unit will operate in
    high fan speed on cooling mode.

    Natural wind by the CHAOS logic
    ❏ For fresher feeling, press the Indoor fan speed selector and set to CHAOS mode. In this mode, the wind
    blows like a natural breeze by automatically changing fan speed according to the CHAOS logic.

    12 Room Air Conditioner



  • Page 13

    Operating Instructions

    Auto changeover operation

    ENGLISH

    1

    Press the Start/Stop button.
    The unit will respond with
    a beep.

    2

    Open the door of the remote controller. To select Auto Changeover
    Operation, press the Operation Mode Selection button.
    Each time the button is pressed, the operation mode is shifted in the
    direction of the arrow.

    Cooling

    3

    Auto
    changeover

    Healthy
    Dehumidification

    Heating
    (Heat pump model only)

    Close the door of the remote controller. Set the temperature
    lower than the room temperature. The temperature can be
    set within a range of 18°C~30°C at intervals of 1°C.
    To raise the temperature

    ON

    To lower the temperature

    4

    Set the fan speed again with the door
    of the remote controller still closed.
    You can select the fan speed in four
    steps-low, medium, high and CHAOS.
    Each time the button is pressed, the
    fan speed mode is shifted.

    During Auto changeover Operation
    ❏ The air conditioner changes the operation mode automatically to keep indoor temperature. When room
    temperature vary over ±2°C with respect to setting temperature, air conditioner keeps the room
    temperature within ±2°C with respect to setting temperature by auto changeover mode.

    Owner's Manual 13



  • Page 14

    Operating Instructions

    Auto operation (Optional)

    1

    Press the Start/Stop button.
    The unit will respond with
    a beep.

    2

    Open the door of the remote controller. To select Auto
    Operation, press the operation mode selection button.
    Each time the button is pressed, the operation mode is
    shifted in the direction of the arrow.

    Cooling

    ON

    3

    Auto

    Healthy
    Dehumidification

    Heating
    (Heat pump model only)

    The temperature and fan speed are automatically set by the
    electronic controls based on the actual room temperature. If
    you want to change the set temperature, press the Room
    Temperature Setting buttons. The cooler or warmer you feel,
    the more times (up to two times) you should press the button.
    The set temperature will be changed automatically.

    To raise the temperature

    To lower the temperature

    During Auto Operation
    ❏ You cannot control the indoor fan speed. It has already been set by the Fuzzy rule.
    ❏ If the system is not operating as desired, manually switch to another mode. The system will not
    automatically switch from the cooling mode to the heating mode, or from heating mode to cooling
    mode, it must be done by manually resetting.
    ❏ During Auto Operation, pressing the chaos swing button makes the horizontal louvers swing up and
    down automatically. If you want to stop auto-swing, press the chaos swing button again.

    14 Room Air Conditioner



  • Page 15

    Operating Instructions

    Healthy dehumidification operation

    Press the Start/Stop button.
    The unit will respond with
    a beep.

    2

    Open the door of the remote controller. To select Healthy
    Dehumidification Operation, press the Operation Mode
    Selection button.
    Each time the button is pressed, the operation mode is
    shifted in the direction of the arrow.

    Cooling

    3
    ON

    ENGLISH

    1

    Auto
    changeover

    Healthy
    Dehumidification

    Heating
    (Heat pump model only)

    Set the fan speed again with the door
    of the remote controller still closed.
    You can select the fan speed in four
    steps-low, medium, high, or CHAOS.
    Each time the button is pressed, the
    fan speed mode is shifted.

    Natural wind by the CHAOS logic
    ❏ For fresher feeling, press the Indoor Fan Speed Selector and set
    to CHAOS mode. In this mode, the wind blows like a natural
    breeze by automatically changing fan speed according to the
    CHAOS logic.

    During Healthy Dehumidification Operation
    ❏ If you select the dehumidification mode on the operation selection button, the A/C starts to run the
    dehumidification function. It automatically sets the room temp. and airflow volume to the best
    condition for dehumidification, based on the sensed current room temp.
    In this case, however, the setting temp. is not displayed on the remote controller and you are not able to
    control the room temp. either.
    ❏ During the healthy dehumidification function, the airflow volume is automatically set according to the
    optimization algorithm responding to the current room temp. status, so that the room condition is kept
    healthy and comfortable even in the very humid season.

    Owner's Manual 15



  • Page 16

    Operating Instructions

    Heating operation (Heat pump model only)

    1

    Press the Start/Stop button.
    The unit will respond with
    a beep.

    2

    Open the door of the remote controller. To select Heating
    Operation, press the Operation Mode Selection button.
    Each time the button is pressed, the operation mode is
    shifted in the direction of the arrow.

    Cooling

    3
    ON

    Auto
    changeover

    Healthy
    Dehumidification

    Heating
    (Heat pump model only)

    Close the door of the remote controller.
    Set the temperature higher than the room temperature.
    The temperature can be set within a range of 16°C~30°C at
    intervals of 1°C.
    To raise the temperature

    To lower the temperature

    4

    Set the fan speed again with the door of the
    remote controller still closed. You can
    select the fan speed in four steps–low,
    medium, high and CHAOS. Each time the
    button is pressed, the fan speed mode is
    shifted.

    Natural wind by the CHAOS logic
    ❏ For fresher feeling, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the
    wind blows like a natural breeze by automatically changing fan speed according to the CHAOS logic.

    16 Room Air Conditioner



  • Page 17

    Operating Instructions

    Jet cool operation

    ENGLISH

    1

    Press the Start/Stop button.
    The unit will respond with
    a beep.

    2

    Press the Jet Cool button to operate the speed cooling mode
    and the unit will operate at super high fan speed on cooling
    mode for 30 minutes.

    Auto
    changeover

    Cooling

    Healthy
    Dehumidification

    Heating
    (Heat pump model only)

    3

    To cancel the Jet Cool mode, press the Jet
    Cool button, the fan speed button or the room
    temperature setting button again and the unit
    will operate at high fan speed on cooling
    mode.

    4

    To cancel the Jet Cool mode, press the Jet Cool button or
    the fan speed button or the room temperature setting button
    again and the unit will operate in high fan speed on cooling
    mode.

    ON

    or

    or

    NOTICE
    ❏ During the JET COOL function at any moment, the A/C starts to blow the cool air at extremely high
    speed for 30 minutes setting the room temp. automatically to 18°C. It is especially used to cool the
    room temp. quickly in a hot summer.
    In heat pump mode, neuro fuzzy mode, or auto changeover mode however, the JET COOL function
    is not available.
    ❏ In order to return to the normal cooling mode from the JET COOL mode, just press the operation
    mode selection button, airflow volume selection, temp. setting button or the JET COOL button again.

    Owner's Manual 17



  • Page 18

    Operating Instructions

    Jet heat operation (Optional)

    1

    Press the Start/Stop button.
    The unit will respond with
    a beep.

    2

    Open the door of the remote controller.
    To select Heating Operation.

    Cooling

    Auto
    changeover

    Healthy
    Dehumidification

    Heating
    (Heat pump model only)

    3

    Press the Jet Heat button to operate the
    speed heating mode and the unit will
    operate at super high fan speed on heating
    mode for 60 minutes.

    4

    To cancel the Jet Heat mode, press the Jet Heat button,
    the fan speed button or the room temperature setting
    button again and the unit will operate at high fan speed on
    heating mode.

    ON

    or

    or

    NOTICE

    ❏ During the JET HEAT function at any moment, the A/C starts to blow the heat air at extremely high speed for
    60 minutes setting the room temp. automatically to 30°C. It is especially used to heat the room temp. quickly
    in a cool winter.
    On cooling, healthy dehumidification mode or auto changeover mode, however, the JET HEAT function is not
    available.
    ❏ In order to return to the normal heating mode from the JET HEAT mode, just press the operation mode
    selection button, airflow volume selection, temp. setting button or the JET HEAT button again.

    18 Room Air Conditioner



  • Page 19

    Operating Instructions

    PLASMA purification operation(Optional)

    ENGLISH

    1

    Press the Start/Stop button.
    The unit will respond with a
    beep.

    2

    Open the door of the remote
    controller. Press the PLASMA
    button.
    Operation will start when the button
    is pressed and stop when the button
    is pressed again.

    3

    Set the fan speed again with the door of the remote
    controller closed. You can select the fan speed in four
    steps-low, medium, high or CHAOS.
    Each time the button is pressed, the fan
    speed mode is shifted.
    ❈ Air purifying operation ( PLASMA) can be
    with cooling, Heating or any other operations.

    NANO PLASMA Air Purifying Operation only
    If you press the only PLASMA button, only
    PLASMA purification function operates.
    Then, fan speed is low. You can select the fan
    speed in four steps-low, medium, high or
    CHAOS.
    Each time the button (
    ) is pressed, the fan
    speed mode is shifted.

    Owner's Manual 19



  • Page 20

    Operating Instructions

    2nd F operation

    1

    Press the Start/Stop button.
    The unit will respond with
    a beep.

    2

    Open the door of the remote control and press the 2nd
    Function button to operate functions printed in blue unter
    buttons.
    (Check the indication of 2nd function on the display of the
    remote controller.)
    These buttons can set the timer as follows:

    ON

    OFF

    SET

    CANCEL
    ON

    OFF

    SET
    AUTO CLEAN

    3

    2nd function disappears in a short time automatically or when
    the button is pressed again.

    For more details, refer to functions next pages.

    20 Room Air Conditioner



  • Page 21

    Operating Instructions

    Additional Features
    Sleep mode
    2. The Timer is programmed in one-hour increments by pressing the Sleep Mode Auto button 1 to 7 times. The
    sleep mode is available for 1 to 7 times. To alter the time period in steps of 1 hour, press the Sleep Mode
    Button while aiming at air conditioner.
    3. Make sure the Sleep Mode Auto LED lights up.
    To cancel the Sleep Mode, press the sleep Mode Auto button several times until the star
    (
    ) disappears from the operation display.
    NOTICE The Sleep Mode will be operated at slow fan speed (cooling) or medium fan speed (heat pump
    only) for a comfortable sleep.
    In sleep mode: Chaos Swing function does not operate.
    In cooling mode or healthydehumidification mode:
    The temperature will automatically rise by 1°C over the next 30 minutes and by 2°C in 1 hour for a comfortable
    sleep.

    Setting the time
    1. Time can be set only when you press the Reset button. Having replacing the batteries,
    you should press the reset buttons to reset the time. Press the Start/Stop button.
    2. Press 2nd F button and check if 2nd F icon is on.
    3. Press the Time Setting buttons until the desired time is set.
    CANCEL

    4. Press the Timer SET button.
    NOTICE

    SET

    Check the indicator for A.M. and P.M.

    Delay start/Pre-set stop
    1. Make sure the time is set correctly on the display of the remote controller.
    2. Press 2nd F button.
    3. Press the ON/OFF Timer buttons to turn Timer on or off.

    ON

    OFF

    4. Press the Time Setting buttons until the desired time is set.
    5. To set the selected time, press the Timer setting button aiming the remote controller at the
    signal receptor.

    CANCEL
    SET

    To cancel the timer setting
    CANCEL
    Check if 2nd F icon is off.
    Press the Timer Cancel button aiming the remote controller at the signal receptor.
    SET
    (The timer lamp on the air conditioner and the display will go out.)

    NOTICE

    Select one of the following four types of operation.

    Delay OFF Timer

    Delay ON Timer

    with the unit running

    Delay OFF and ON Timer Delay ON and OFF Timer

    Owner's Manual 21

    ENGLISH

    1. Press the Sleep Mode Auto button to set the time you want the unit to stop automatically.



  • Page 22

    Operating Instructions

    Vertical Airflow Direction Control
    The up/down airflow (Vertical Airflow) can be adjusted
    by using the remote control.

    1. Press the Start/Stop button to start the unit.
    2. Press Chaos Swing button and the louvers will
    swing up and down.
    Press the Chaos Swing button
    again to set the vertical louver
    at the desired airflow direction.

    NOTICE
    ❏ If you press the CHAOS swing button, the horizontal airflow
    direction is changed automatically based on the CHAOS
    algorithm to distribute the air in the room evenly and at the
    same time to make the human body feel most comfortable,
    as if enjoying a natural breeze.
    ❏ Always use the remote control to adjust the up/down
    airflow direction. Manually moving the vertical airflow
    direction louver by hand, could damage the air
    conditioner.
    ❏ When the unit is shut off, the up/down airflow direction
    louver will close the air outlet vent of the system.

    Horizontal Airflow Direction Control (Optional)
    The left/right(Horizontal Airflow) can be adjusted by using the remote control.
    Press the Start/Stop button to start the unit.
    Open the door on the remote control. Press the Airflow Direction Start/Stop button and the
    louvers will swing left and right. Press the Horizontal Airflow Direction Control Button again to
    set the horizontal louver at the desired airflow direction.

    Energy-Saving Cooling Mode (Optional)
    Energy-Saving Cooling Mode Can save energy in Cooling and Healthy Dehumidification Operation, because it can
    operate efficiently by setting body-adaptation time according to the change of time and temperature and adjusting
    automatically desired temperature.
    1. Press the Start/Stop button to start the unit.
    2. Open the door on the remote control.
    Select Cooling Operation or Healthy Dehumidification Operation.
    3. Press the Energy-Saving Cooling Mode button.
    4. To cancel the Energy-Saving Cooling Mode, press the Energy-Saving Cooling Model
    button and unit will operate in previous Mode(Cooling or Healty Dehumidification
    Mode).

    22 Room Air Conditioner



  • Page 23

    Operating Instructions

    Auto clean(Optional)

    NOTICE

    This function is to remove unpleasant smells from mold and other bacteria in the air-conditioner, and to remove
    humidity automatically during humidly summer, which supplies the indoor with purified air.

    Forced operation
    Operation procedures when the remote control can't be used.
    The operation will be started if the power button is pressed.
    If you want to stop operation, re-press the button.

    Cooling Model
    Operating mode
    Indoor FAN Speed
    Setting Temperature

    Cooling
    High
    22°C

    Room Temp. ≥ 24°C
    Cooling
    High
    22°C

    Heat pump Model
    21°C ≤ Room Temp. < 24°C
    Healthy Dehumidification
    High
    23°C

    Power
    button

    Room Temp. < 21°C
    Heating
    High
    24°C

    Test operation
    During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room
    temperature and resets in 18 minutes.
    During test operation, if remote controller signal is received, the unit operates as remote controller sets.
    If you want to use this operation, open the front panel upward and Press the power button let it be pressed for
    about 3 seconds.
    If you want to stop the operation, re-press the button.

    Auto restart
    In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate
    procedures automatically to the previous operating conditions.
    So there is no need of activating this function by pressing any key or button.
    In the initial mode, the fan operates at a low speed and the compressor starts 2.5~3 minutes later.
    As the compressor starts, the fan speed also resumes its previous setting mode.

    Helpful information
    High
    Speed

    Fan speed and cooling capacity.
    The cooling capacity indicated in the specification is the value when the
    fan speed is set to high, and the capacity will be lower at low or medium
    fan speed.
    High fan speed is recommended when you wish to cool the room quickly.

    Owner's Manual 23

    ENGLISH

    AUTO CLEAN

    1. Whenever you press the Auto Clean button, Auto Clean Function will be reserved and cancelled.
    2. Auto Clean function works before and after cooling or dehumidification mode. For details, refer
    to the below points.
    3. When the unit is started after the reservation of Auto Clean ,the Cool Start function operates and
    indoor Fan is started after 20 seconds.
    4. When you press Start/Stop button to turn off the unit after the you have reserved Auto Clean
    function, the air-conditioner circulates the indoor air in the Auto Clean mode with no more
    Cooling or Dehumidification operation. For Cooling only model, it lasts for 30 minutes for Heat
    pump model, for 16 minutes.
    5. If you press the auto clean button again during the product operation , Auto Clean function will
    be cancelled.



  • Page 24

    Maintenance and Service

    Maintenance and Service
    Indoor Unit
    WARNING: Turn the system off before cleaning.
    To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives.
    NOTICE

    Supply power must be disconnected before cleaning the indoor unit.

    1. Open the upside of Front Panel

    Front panel

    2. Put up the Front panel.
    The hook of panel comes off.

    Panel hook

    3. Come down the panel and then remove the air filter.
    Air filters

    WARNING: Don’t touch the PLASMA Filter
    within 10 seconds after opening the inlet
    grille, it may cause electric shock.
    4. Clean it wi a soft brush and the vacuum cleaner.
    If it is very dirty, wash it with water.

    5. Reinstall the air filter dried at the shade and then close
    the panel.
    Air filters

    ❏ Never use any of the followings:
    • Water hotter than 40°C
    Could cause deformation and/or discoloration.
    • Volatile substances
    Could damage the surfaces of the air conditioner.

    24 Room Air Conditioner

    Pow

    d er

    G a s o li n e



  • Page 25

    Maintenance and Service

    Outdoor Unit

    NOTICE

    Dirty or clogged coils will reduce the
    operating efficiency of the system and
    cause higher operating costs.

    (Rear)
    Air intake
    vents

    (Side)
    Piping
    Drain Hose

    Air outlet
    vents

    (Rear)

    Air intake
    vents

    (Rear)

    (Side)
    Piping
    Drain Hose

    Air outlet
    vents

    Air intake
    vents

    (Side)
    Piping
    Drain Hose

    Air outlet
    vents

    Cleaning Filter
    • Recomended use period : About 3 months
    1. Open the upside of Front
    panel.

    2. Put up the front panel.
    The hook of panel comes off.

    3. Remove air filter and then pull
    out the nano plasma filter.
    Nano plasma filter

    Front panel

    Panel
    hook

    4. Clean nano plasma filter with
    the vacuum cleaner.

    5. Relocate dried nano plasma
    filter at the shade and then put
    in air filter.

    Nano plasma filter

    Owner's Manual 25

    ENGLISH

    The heat exchanger coils and panel vents of the outdoor unit should be checked regularly.
    If clogged with dirt or soot, the heat exchanger
    and panel vents may be professionally steam cleaned.



  • Page 26

    Maintenance and Service

    When the air conditioner is not going to be used for a long time.
    When air conditioner is not going to be
    used for a long time.

    When the air conditioner is to be used again.

    Operate the air conditioner on mode for 2 to
    3 hours.

    Clean the air filter and install it in the indoor
    unit.
    (Refer to page 24 for cleaning filters.)

    • This will dry out the internal mechanisms.

    Turn off the circuit breaker, and disconnect
    the plug.
    Check that the air inlet and outlet of the
    indoor/outdoor unit are not blocked.

    CAUTION: Turn off the circuit
    breaker when the air conditioner is not
    going to be used for a long time.
    Dirt may collect and may cause a fire.
    Remove the batteries from the remote
    control.

    Operation Tips
    Do not overcool the room.

    Keep blinds or curtains
    closed.

    Keep the room temperature
    uniform.

    This is not good for the health
    and wastes electricity.

    Do not let direct sunshine enter
    the room when the air
    conditioner is in operation.

    Adjust the vertical and
    horizontal airflow direction to
    ensure a uniform temperature
    in the room.

    Make sure that the doors
    and windows are shut tight.

    Clean the air filter regularly.

    Ventilate the room
    occasionally.

    Avoid opening doors and
    windows as much as possible
    to keep the cool air in the room.

    Blockages in the air filter
    reduces the airflow and lowers
    the cooling and dehumidifying
    effects. Clean at least once in
    every two weeks.

    Since windows are kept closed,
    it is a good idea to open them
    and ventilate the room now and
    then.

    26 Room Air Conditioner



  • Page 27

    Maintenance and Service

    Troubleshooting
    Check the following points before requesting repairs or service.... If the fault persists, please contact your dealer
    or service center.

    Explanation

    See page

    The air conditioner does not
    operate.

    • Have you made a mistake in timer operation?
    • Has the fuse blown or has the circuit breaker
    been tripped?

    21
    -

    The room has a peculiar
    odor.

    • Check that this is not a damp smell exuded by
    the walls, carpet, furniture, or cloth items in the
    room.

    -

    It seems that condensation
    is leaking from the air
    conditioner.

    • Condensation occurs when the airflow from
    the air conditioner cools the warm room air.

    -

    Air conditioner does not
    operate for about 3 minutes
    when restarted.

    • This is the protector of the mechanism.
    • Wait about three minutes and operation will
    begin.

    -

    Does not cool or heat
    effectively.

    • Is the air filter dirty? See air filter cleaning
    instructions.
    • Has the temperature been set incorrectly?
    • Are the indoor unit's air inlet or outlet vents
    obstructed?

    The air conditioner
    operation is noisy.

    24
    12, 16
    -

    • For a noise that sounds like water flowing.
    -This is the sound of freon flowing inside the
    air conditioner unit.
    • For a noise that sounds like the compressed
    air releasing into atmosphere.
    -This is the sound of the dehumidifying water
    being processed inside the air conditioning
    unit.

    -

    Remote control display is
    faint, or no display at all.

    • Are the batteries depleted?
    • Are the batteries inserted in the opposite (+)
    and (-) directions?

    10

    Crack sound is heard.

    • This sound is generated by the
    expansion/constriction of the front panel, etc.
    due to changes of temperature.

    -

    Owner's Manual 27

    ENGLISH

    Case



  • Page 28

    Memo

    28 Room Air Conditioner



  • Page 29

    P/No.: 3828A20283D(Inverter-Series)
    Printed in Korea
    After reading this manual, keep it in a place easily accessible to the user for future reference.






Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für LG ASUW2463 MH0 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Holen Sie sich Ihr Benutzerhandbuch per E-Mail

Geben Sie Ihre E-Mail-Adresse ein, um das Handbuch zu erhalten von LG ASUW2463 MH0 in der Sprache / Sprachen: Englisch als Anhang in Ihrer E-Mail.

Das Handbuch ist 1,75 mb groß.

 

Sie erhalten das Handbuch in Ihrer E-Mail innerhalb von Minuten. Wenn Sie keine E-Mail erhalten haben, haben Sie wahrscheinlich die falsche E-Mail-Adresse eingegeben oder Ihre Mailbox ist zu voll. Darüber hinaus kann es sein, dass Ihr ISP eine maximale Größe für E-Mails empfangen kann.

Andere Handbücher von LG ASUW2463 MH0

LG ASUW2463 MH0 Bedienungsanleitung - Deutsch - 29 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info