P/NO : MFL69517401
AC Ez Touch
PACEZA000, CACEZA000
www.lg.com
Please read this manual carefully before operating
your set and retain it for future reference.
INSTALLATION / USER MANUAL
AIR
CONDITIONER
ENGLISH
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Inhalt der Seiten


  • Page 1

    ENGLISH

    INSTALLATION / USER MANUAL

    AIR
    CONDITIONER

    Please read this manual carefully before operating
    your set and retain it for future reference.
    AC Ez Touch
    PACEZA000, CACEZA000

    www.lg.com
    P/NO : MFL69517401



  • Page 2

    2

    TABLE OF CONTENTS

    ENGLISH

    TABLE OF CONTENTS
    3
    4

    TIPS FOR SAVING ENERGY
    IMPORTANT SAFETY INSTRUCTIONS

    7

    COMPONENTS

    8

    PRODUCT SPECIFICATION

    33

    Delete schedule

    34

    View report

    36

    Emergency stop

    37

    Setting

    38

    Operation setting

    41

    Group setting

    44

    System setting

    45

    System setting (General setting)

    48

    System setting (Advanced setting)

    9

    NAME OF EACH PART

    53

    Screen setting

    9

    Name

    56

    Installer setting

    62

    PC access

    63

    Installation and setting

    64

    Installation environment check and setting up the equipment address

    66

    Central control address of the indoor
    unit set-up

    10 HOW TO USE
    10

    Menu composition

    11

    Home screen composition and function

    12

    Top bar detail screen

    13

    Status screen

    72

    Check list before calling for service

    14

    Menu screen

    72

    Guide to open source software

    15

    Control screen

    18

    Information input method

    19

    Air conditioner control

    24

    Ventilation(ERV and ERV DX) control

    26

    Heating control

    28

    Schedule view

    29

    Add schedule

    31

    Edit schedule



  • Page 3

    TIPS FOR SAVING ENERGY

    3

    Here are some tips that will help you minimize the power consumption when you use the air
    conditioner. You can use your air conditioner more efficiently by referring to the instructions
    below.
    • Do not cool excessively indoors. This may be harmful for your health and may consume more
    electricity.
    • Block sunlight with blinds or curtains while you are operating the air conditioner.
    • Keep doors or windows closed tightly while you are operating the air conditioner.
    • Adjust the direction of the air flow vertically or horizontally to circulate indoor air.
    • Speed up the fan to cool or warm indoor air quickly, in a short period of time.
    • Open windows regularly for ventilation as the indoor air quality may deteriorate if the air conditioner is used for many hours.
    • Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may block
    the air flow or weaken the cooling / dehumidifying functions.

    For your records
    Staple your receipt to this page in case you need it to prove the date of purchase or for warranty
    purposes. Write the model number and the serial number here.
    Model name :
    Serial number :
    You can find them on a label on the side of each unit.
    Dealer’s name :
    Date of purchase :

    ENGLISH

    TIPS FOR SAVING ENERGY



  • Page 4

    IMPORTANT SAFETY INSTRUCTIONS

    4

    ENGLISH

    IMPORTANT SAFETY INSTRUCTIONS
    READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
    • The installation work requires a specialized technology, so it shall be installed through the service center or an installation specialized store acknowledged by LG.
    • If the installation work is done without an installation license, the installer will be responsible for all
    problems related to the installation, and in such case, LG will not provide the free of charge A/S.
    • The following safety related cautions are to prevent the unexpected risk or damage in advance.

    ! WARNING
    If the instructions are not followed, it may cause death or severe injury of the user.

    ! CAUTION
    If the instructions are not followed, it may cause injury or property damage of the user.
    These are the symbols to alert the matters and operations that may have risks. Please carefully read them and follow the instructions to avoid the risk.

    !

    This is a symbol that indicates the action to avoid for reducing risk.

    !

    NOTE

    System air conditioner is not to be moved. If it has to be moved inevitably, make sure to contact
    the system air conditioner store with LG Electronics system air conditioner installation license.

    ! WARNING
    Installation
    • When you re-install this product, please contact your Supplier or Installation Company to carry
    out the work. If someone inexperienced installs the product, it may result in fire, electric
    shock, explosion, injury, or failure of the product.
    • Ensure there is no damage the power cable. It may cause fire or electric shock.
    • When you perform any electrical work, please contact the Supplier or Installation Company. If
    an inexperienced person performs the disassembly or repair, it may cause fire or electric
    shock.
    • Install the product that can avoid rain water. If water enters into the product, it may cause
    product failure.
    • Do not install the product at a place with a lot of moisture. If moisture enters the product, it
    may cause product failure.
    • Make sure to contact the Supplier or Installation Company for the product installation. If
    someone inexperienced installs the product, it may result in fire, electric shock, explosion, injury, or failure of the product.
    • Please ensure an electrical engineer perform the electric work based on the installation manual and the designated circuit diagram. If incorrect wiring is used, or inexperienced engineer
    performs the electric work, it may cause fire or electric shock.
    • Do not place the product near an electric fire. It may cause fire.
    • Avoid installing this controller in an area with sensitive electronic equipment. It may cause
    electrical interference with sensitive electronics.



  • Page 5

    IMPORTANT SAFETY INSTRUCTIONS

    5

    Operation
    • Do not place a heavy object on the power cable. It may cause fire or electric shock.
    • Do not change or extend the power cable without authorization. It may cause fire or electric shock.
    • Use the cable exclusive for the product. If an unauthorized or non-standard cable it used, it
    may cause fire or electric shock.
    • Do not use a heating equipment near the power cable. It may cause fire or electric shock.
    • Do not let water enter inside the product. It may cause electric shock of product failure.
    • Do not place a container with liquid on the product. It may cause product malfunction.
    • Do not touch the product with wet hand. It may cause fire or electric shock.
    • Use standard parts. If unauthorized parts are used, it may cause fire, electric shock, explosion,
    user injury, or product failure.
    • When the product is flooded, do not use, power off and contact the Service Company. It may
    cause fire or electric shock.
    • Do not impose shock to the product. It may cause product failure.
    • Do not store or use combustible gas or ignition material near the product. It may cause fire or
    product failure.
    • Do not disassemble, repair, or modify the product without authorization. It may cause fire or
    electric shock.
    • Provide adequate supervision for use of the product by children or elderly. The negligence
    may cause safety accident or product failure.
    • Safeguard the product from Children. It may cause product damage to the product or injury of
    the child.
    • Check the operation temperature boundary stated in the manual before using the product. If
    there is no usage boundary stated in the manual, use it in the boundary of 0 °C~ 40 °C (32 °F
    ~ 104 °F). If it is used in an environment exceeding the operation temperature boundary, it
    will seriously damage the product.
    • Do not press the switch or button of the product with a sharp object. It may cause electric
    shock of product failure.
    • Before cleaning, power off the product.
    • If there is an abnormal sound, smell, or smoke from the product, stop using the product. It

    ENGLISH

    • Install the product fixed firmly. If the product is not securely fixed, it may fall and become
    damaged.
    • Correctly install the product after fully studying the provided manual. It may cause fire or electric shock.
    • During the wiring, do not use non-standard cable and do not force or extend the cable. It may
    cause fire or electric shock.
    • During the wiring of the power cable and communication cable, firmly fix the cable. If the
    cable is loose, it may cause fire or electric shock.
    • Do not connect the power cable to a communication terminal. It may cause fire or electric
    shock or it may cause the product failure.
    • Do not install the product in a place where combustible gas may leak. It may cause fire, electric shock, explosion, injury of the user, or product failure.
    • Install the product without tension on the cable. If the tension is applied on the cable, the
    cable may be broken, or it may cause fire by the heat generation.
    • Do not use damaged plugs or connectors. It may cause electric shock or product failure.
    h If it is a model using a plug.



  • Page 6

    6

    IMPORTANT SAFETY INSTRUCTIONS

    ENGLISH

    may cause fire or electric shock.
    • Do not place a heavy object on the product. It may cause product failure.
    • Do not directly spray water on the product or wipe the product with wet towel, etc. It may
    cause fire or electric shock.
    • Do not use the product for special usage such as animal or plant, precision equipment, or
    preservation of art pieces, and do not use the product at a place unsuitable for the installation.
    It may cause property damage.
    • Safely dispose of the packaging material. If it is not disposed, the remaining packaging material may cause injury to the user.
    • When you pull out the power plug, hold the head of the plug, and do not touch the power
    plug with wet hand. - It may cause fire or injury.
    • Make sure to cut off the power of the product during the cleaning or repair. It may cause fire
    or product deformation.

    ! CAUTION
    Installation
    • Install the product firmly on a place that can support the weight of the product. The product
    may fall and be damaged.
    • Do not use the product at a place with grease, steam, or sulphuric acid gas. It may cause
    product performance degradation or product damage.
    • Check the rated power. It may cause fire or product failure.
    • Please use the adaptor provided where necessary. If non-standard adaptor is used, it may
    cause product failure.
    • During the transportation of the product, be careful not to drop or damage the product. It may
    cause product failure or injury of the transporting person.
    • During the wiring, do not let dew, water, insect, etc. enter the connection part where the
    cable is extended. If an foreign object enters, it may cause electric shock or product failure.

    Operation
    • When cleaning the product, do not use strong detergent such as solvents, wipe with a soft
    cloth instead. If strong detergent such as solvents are used, it may cause a fire or the product
    may be deformed.
    • Do not press the touch panel with a pointed or sharp object. It may cause electric shock or
    product failure.
    • Do not let a metal material touch the product. It may cause product failure.
    • Before cleaning, power off the product. It may cause malfunction of the product.
    • Do not touch anything inside the product. It may cause product failure.
    • After a long period of product use, check it for any wear and tear or damage. When the product is used for a long period of time, the product status may become worn or damaged, and it
    may cause user injury during the usage.
    • Do not store the product near liquid such as a vase or water jar. It may cause fire or electric
    shock.
    • When the product is not used for a long period of time, turn off at the main power switch. It
    may cause fire or product failure.



  • Page 7

    COMPONENTS

    ENGLISH

    COMPONENTS

    AC Ez Touch
    Controller

    Wall installation plate

    Wall installation screw

    ENGLISH

    SLOVENČINA

    MAGYAR

    ITALIANO

    SLOVENŠČINA

    БЪЛГАРСKN

    ESPAÑOL

    SRPSKI

    FRANÇAIS

    HRVATSKI

    DEUTSCH

    SVENSKA

    ΕΛΛΗΝΙΚΆ

    NORSK

    ČEŠTINA

    SUOMI

    NEDERLANDS

    DANSK

    POLSKI

    EESTI KEEL

    LIMBA ROMÂNĂ

    MALTI

    PORTUGUÊS

    LATVIEŠU VALODA

    INSTALLATION MANUAL

    LIETUVIŲ KALBA

    AIR
    CONDITIONER

    GAEILGE
    МАКЕДОНСКИ
    SHQIP
    ÍSLENSKA

    Please read this installation manual completely before installing the product.
    Installation work must be performed in accordance with the national
    wiring standards by authorized personnel only.
    Please retain this installation manual for future reference after reading
    it thoroughly.

    BOSANSKI

    AC Ez Touch
    PACEZA000, CACEZA000
    Original instructions

    www.lg.com
    P/NO : MFL69306902

    Power adapter

    !

    7

    Power cord

    Installation / User manual

    NOTE

    The image of components or separately sold products may be different from the actual products.



  • Page 8

    8

    PRODUCT SPECIFICATION

    AC Ez Touch product specification is as follows.

    47.4 mm

    137 mm

    85 mm

    121 mm

    ENGLISH

    PRODUCT SPECIFICATION

    25 mm

    23.7 mm

    Item

    Specification

    Power

    DC 12 V (Adapter)

    Adapter

    Input : 100-240 V~, 50 / 60 Hz , 1.2 A
    Output : DC 12 V, 3.33 A

    LCD

    5 inch color LCD (800 * 480)

    Touch

    C-Type Touch Panel

    485 communication

    Max 1 000 m

    DI

    Max 100 m

    Ethernet

    100 Mbps

    Keyboard

    Korean/English/Number

    Operation temperature

    0 °C ~ 40 °C (32 °F ~ 104 °F)

    Storage temperature

    -20 °C ~ 60 °C (-4 °F ~ 140 °F)



  • Page 9

    NAME OF EACH PART

    ENGLISH

    NAME OF EACH PART
    Name
    ① 噼#OFG#㳝⤲#㎺
    LCD display window

    嚀#᲋#㧡⤶⌫

    LAN communication part

    ② Back button ③ 噾#㼅#㼕᾽
    Home screen
    噽#ᤷᵤ#ཾᇵ#
    button
    ཾᇵ#∑㬉
    ∑㬉

    ④噿#⻾ⶣ
    Power input part

    ⹮ᴥ⌫
    ⑥嚁#7;8
    RS-485
    commu㧡⤶#⌫
    nication

    Reset
    ⑦ AI(Reserved) /
    嚃#Ở❬#∑㬉
    嚂#DL+Ⳃ␈,2
    part
    Button
    DI input part
    GL#⹮ᴥ⌫

    No.

    Item



    LCD display window



    Back button



    Home screen button



    Power input part



    LAN communication part



    RS-485 communication part



    AI/DI Input part



    Reset button

    9

    Specification
    Operation and setting status display
    Move to the previous screen
    Move to the default screen
    DC 12 V Adaptor connection part
    LAN communication connection port for ethernet connection
    (100 Mbps Support)
    1 port
    AI+ : Reserved
    DI+ : Contact point input (dry contact input)
    COM : Common GND
    For system restart



  • Page 10

    10 HOW TO USE

    ENGLISH

    HOW TO USE
    Menu composition

    Start

    Aircon control

    Home (status)

    Heating
    control

    Vent control

    Home (menu)

    Schedule

    Report

    Setting

    Monthly

    Error

    Operation
    setting

    Weekly

    Change alarm

    List

    Energy

    Group setting
    System setting
    Screen setting
    Installer setting

    General user

    Manager
    and installer

    Access rights for each menu
    Detail access rights
    - General user: can access all menu displayed in the screen.
    - Manager and installer: When it enters the setting, the manger and installer are verified by password.



  • Page 11

    HOW TO USE

    11

    It describes the home screen composition and function.
    The home screen is divided to status screen and menu screen.

    ① Easy







    information

    ② Detail

    screen





    No.

    Item

    Specification



    Easy information

    Controller name / error message / current time



    Detail screen

    Provides operation status and today's schedule



    Controller name

    Displays the controller name
    (can edit in ‘Setting > System setting > General > Controller name’)



    Error message

    It displays the current number of the errors that occurred, and it
    displays the detail screen when the top bar is pressed.



    Current time

    Current time display
    (can edit in ‘Setting > System setting > General > Time setting’)



    Status screen

    Provides today's schedule / entire equipment operation status



    Menu screen

    Provides menu for detail control / setting

    ENGLISH

    Home screen composition and function



  • Page 12

    12 HOW TO USE

    ENGLISH

    Top bar detail screen
    tab on Top bar area














    No.

    Item

    Specification



    Setting status



    Notice list



    Close

    When it is selected, the notice list area is closed



    Lock

    Displays the number of locked (entire lock) devices



    Schedule

    Displays the number of the entire schedules



    Occupied

    Displays the number of currently occupied equipments (applied only
    for overseas model)



    Detail display

    Set function list area
    Displays the number of each notice
    (error, oil change, filter change)

    Error: move to the error report menu
    Change alarm: move to the change alarm report menu
    - Oil change / Filter change



  • Page 13

    HOW TO USE 13

    ENGLISH

    Status screen











    No.

    Item

    Specification



    Status screen

    Provides today's schedule / operation status as fixed display



    Operation status

    Displays the number of entire indoor unit
    (Air conditioner + Ventilation + Heating) operation/stop/error



    Entire control



    Today’s schedule



    Schedule

    Entire indoor unit (Air conditioner + Ventilation + Heating)
    operation/stop control
    Sort today's schedule in timely order
    - displays time information and name of the schedule
    - If there are 4 or more today's schedules, "More" button is displayed
    - If "More" button is pressed, it moves to "Schedule> Monthly" screen

    Displays the screen according to the number of today's schedules

    If the schedules are 3 or less

    If there is no schedule



  • Page 14

    14 HOW TO USE

    ENGLISH

    Menu screen



    No.



    Item

    Menu screen

    Specification
    The component of menu is different depending on the type of the
    connected equipment.
    When the menu is selected, it moves to the control screen.
    h In case of the menu screen, the location of the menu changes according to the connected product.

    <In case when
    Only air conditioner is connected>

    <When air conditioner and ventilation
    are connected>



  • Page 15

    HOW TO USE 15

    ENGLISH

    Control screen

    1. Equipment display area
    - It displays group and individual equipment in 3*4 matrix.
    - It is positioned at the top when a group is created.
    4ea

    Group

    3ea
    Individual
    equipment

    <Group/individual
    equipment position>

    <It is positioned at the top
    when a group is created>

    2. Equipment name display
    - When an equipment is selected, a detail status screen appears.
    (The number of letters for the equipment name set in the installer setting device management is restricted to 20.)

    <Equipment detail status screen>

    <Equipment name abbreviation
    display screen>



  • Page 16

    16 HOW TO USE

    ENGLISH

    3. Page move button
    - It is activated when the control screen's number of equipment or groups is 13 or more.
    - Current page number / entire number of pages and buttons
    4. Group / equipment display
    - Group
    If the corresponding group's equipment is on, it displays the number of turned on equipments (ON N equipments).
    If all of the equipment in the corresponding group are turned off, it displays stop text.
    On state

    Off state

    - Individual Air conditioner
    Displays indoor temperature, operation mode, and status icon (lock / occupied).
    If it is stop state, it is displayed in gray, and the color is displayed differently for each mode.
    Cool(blue), Heat(orange), Fan(green), Dry(dark blue), Auto(purple)

    - Individual Ventilation(ERV/ERV DX)
    Displays indoor temperature, operation mode, and status icon (lock).
    If it is stop state, it is displayed in gray, and the color is displayed differently for each mode.
    Normal(blue), HEX(orange), Auto(purple)

    - Individual Heating
    Displays indoor temperature, operation mode, and status icon (lock).
    If it is stop state, it is displayed in gray, and the color is displayed differently for each mode.
    Cool(blue), Heat(orange), Auto(purple)

    !

    NOTE

    In case of Heating Device
    - If hot water operation is ‘ON’, the icon is displayed as in operation even if operation is in OFF
    state.
    - If hot water operation is ‘ON’, the icon is displayed as heating color regardless of the actual
    mode.



  • Page 17

    HOW TO USE 17

    Item

    Specification

    !

    When an error occurs

    !

    In case of oil/filter change alarm

    h If error, oil change alarm, and filter change alarm occur at the same time, the error is displayed
    with the priority. Error alarm has a high priority.
    6. When [Energy save mode] icon is pressed
    When [Energy save mode] icon in the Air conditioner control screen is pressed, the energy
    save mode becomes on.
    When the energy save mode is on, the [Energy save mode] icon is lighted in green, and the
    operation state change control is repeated according to the setting of energy save mode
    cycle.
    h Energy save mode operates the air conditioner only.
    - During the cooling operation: Cool ↔ Fan, Lock all
    - During the heating operation: Heat ↔ OFF, Lock all

    !

    NOTE

    In slave state, you cannot use each equipment’s lock setting, set temp range, 2set point, IDU
    2set, auto search device function, energy report and energy save mode.

    ENGLISH

    5. When an error occurs
    - Error icon is displayed.
    - In case of a group, if there is at least 1 indoor unit with error in the group, it is applied.



  • Page 18

    18 HOW TO USE

    ENGLISH

    Information input method
    A touch keyboard appears at the bottom of the screen by touching the information input column.
    Enter information using the touch keyboard.

    OK

    < Keyboard display screen>

    !

    NOTE

    When you press number input
    field, you can directly input the
    number for the setting.

    OK



  • Page 19

    HOW TO USE 19

    In this screen, you can control the air conditioner indoor unit group/individual equipment or check
    the status.
    Control button, selection box to control group/individual equipment appears.
    1. When you press

    <Status view screen>
    2. After selecting the equipment to control, when you press
    control screen.
    - In the detail control screen, set the detail status.

    <Control screen>
    Done

    button, it enters the detail

    3. After changing the setting in the detail control screen, when you press
    the control command is executed.

    <Select equipment to control>

    <Control completed message display>

    Apply

    button,

    <Detail control screen>

    ENGLISH

    Air conditioner control



  • Page 20

    20 HOW TO USE

    ENGLISH

    <General control category>

    Classification

    Detail control

    Operation

    ON/OFF

    Set temp

    18 °C ~ 30 °C / 64 °F ~ 86 °F

    Mode

    COOL/HEAT/DRY/FAN/AUTO

    Lock

    Hard Lock/Temp Lock/Mode Lock/Fan Lock/Clear

    Fan speed

    Low/Med/High/Auto

    Swing

    ON/OFF

    Set temp range

    Lower: 16 °C ~ 30 °C / 60 °F ~ 86 °F
    Upper: 18 °C ~ 30 °C / 64 °F ~ 86 °F
    (Even if the temperature display setting is in Celsius /
    0.5 °C unit, setting is possible only in 1 °C unit.)

    2set point /
    IDU 2set

    ON/OFF
    (Refer to the description for
    the auto mode option setting / operation setting.)



  • Page 21

    HOW TO USE 21

    ENGLISH

    <Lock setting screen>

    <Control mode setting screen>

    <Temperature limit setting screen>

    !

    NOTE

    According to the product type, some additional functions may not be displayed or not operational. In slave state, you cannot use each equipment’s lock setting, set temp range, 2set point,
    IDU 2set, auto search device function, energy report and energy save mode.



  • Page 22

    22 HOW TO USE

    ENGLISH

    <Auto control setting category>

    <AutoChangeover/Setback setting screen>

    Classification

    Auto
    Changeover

    Whether used

    ON/OFF

    Fan

    Low/Med/High/Auto

    Temp range

    Lower: 18 °C ~ 30 °C / 64 °F ~ 86 °F
    Upper: 18 °C ~ 30 °C / 64 °F ~ 86 °F

    Whether used

    ON/OFF

    Start temp

    Cooling: 21 °C ~ 40 °C / 70 °F ~ 104 °F
    Heating: 1 °C ~ 20 °C / 34 °F ~ 68 °F

    Setback

    !

    Detail control

    NOTE

    In slave state, you cannot use each equipment’s lock setting, set temp range, 2set point, IDU
    2set, auto search device function, energy report and energy save mode.



  • Page 23

    HOW TO USE 23

    ENGLISH

    <Advanced setting category>

    <2set Auto mode setting screen>

    Classification

    Detail control

    Occupancy setting

    ON(Occupied)/OFF(Unoccupied)

    Cool set temperature

    10 °C ~ 37.5 °C / 50 °F ~ 99 °F

    Cool upper temperature

    10 °C ~ 37.5 °C / 50 °F ~ 99 °F

    Cool lower temperature

    10 °C ~ 37.5 °C / 50 °F ~ 99 °F

    Heat set temperature

    4 °C ~ 32 °C / 40 °F ~ 90 °F

    Heat upper temperature

    4 °C ~ 32 °C / 40 °F ~ 90 °F

    Heat lower temperature

    4 °C ~ 32 °C / 40 °F ~ 90 °F

    !

    NOTE

    - 2set auto mode is a US-only option.
    Only indoor and outdoor group 2set support the automatic mode, you can use the feature.
    (please refer to the manual for that device, whether it supports 2set function for each device.)
    - 2set auto mode should be set in Settings> Operation Settings> Auto Mode option menu, you
    can use the feature.
    - In slave state, you cannot use each equipment’s lock setting, set temp range, 2set point, IDU
    2set, auto search device function, energy report and energy save mode.



  • Page 24

    24 HOW TO USE

    ENGLISH

    Ventilation(ERV and ERV DX) control
    In this screen, you can control Ventilation(ERV and ERV DX)’s group/individual equipment or
    check the status.
    1. When you press Control button, selection box to control group/individual equipment appears.

    <Status view screen>

    <Control screen>

    2. After selecting the equipment to control, when you press Done button, it enters the detail
    control screen.
    - In the detail control screen, set the detail status.
    3. After changing the setting in the detail control screen, when you press Apply button, the control command is executed.

    <Select equipment to control>

    <ERV detail control screen>

    <ERV DX detail control screen>

    <Control completed message display>



  • Page 25

    HOW TO USE 25

    ENGLISH

    <General control category>

    Classification

    ERV

    ERV DX

    Operation

    ON/OFF

    ON/OFF

    Mode

    HEX/NORMAL/AUTO

    HEX/NORMAL/AUTO

    Lock

    Lock/Clear

    Lock/Clear

    Fan

    Low/High/Super/Auto

    Low/High/Super/Auto

    Set temp

    -

    18 °C ~ 30 °C / 64 °F ~ 86 °F
    (Even if the temperature display setting is in Celsius /
    0.5 °C unit, setting is possible only in 1 °C unit.)

    Additional function

    Drift/Quick/Clear

    Drift/Quick/Clear

    Heater

    ON/OFF

    ON/OFF

    Humid

    -

    ON/OFF
    (Setting is possible only in
    air conditioner heat mode operation.)

    Co-Air conditioner

    -

    COOL/HEAT/AUTO/STOP

    !

    NOTE

    According to the product type, some additional functions may not be displayed or not operational. When ERV and ERV DX are selected at the same time, the ERV control screen is displayed.



  • Page 26

    26 HOW TO USE

    ENGLISH

    Heating control
    In this screen, you can control the heating’s group / individual equipment or check the status.
    1. When you press Control button, selection box to control group/individual equipment appears.

    <Status view screen>
    2. After selecting the equipment to control, when you press
    control screen.
    - In the detail control screen, set the detail status.

    <Control screen>
    Done

    button, it enters the detail

    3. After changing the setting in the detail control screen, when you press
    the control command is executed.

    <Select equipment to control>

    <Control completed message display>

    Apply

    button,

    <Detail control screen>



  • Page 27

    HOW TO USE 27

    ENGLISH

    <General control category>

    Classification

    Detail control

    Operation

    ON/OFF

    Hot water

    ON/OFF

    Lock

    Lock/Clear

    Mode

    COOL/HEAT/AUTO

    Set temp

    Product type
    1) WHU[Hydrokit]
    3) CASCADE
    Air temp (Cool) : 18 °C ~ 30 °C / 64 °F ~ 86 °F
    Air temp (Heat) : 16 °C ~ 30 °C / 60 °F ~ 86 °F
    Air temp (Heat) : 16 °C ~ 30 °C / 60 °F ~ 86 °F
    Water temp(Heat) : 30 °C ~ 80 °C / 86 °F ~ 176 °F
    Water temp(Cool) : 6 °C ~ 25 °C / 42 °F ~ 77 °F
    Water temp(Heat) : 20 °C ~ 50 °C / 68 °F ~ 122 °F
    2) SINGLE_AWHP
    4) HEAT_ONLY_AWHP
    Air temp (Cool) : 16 °C ~ 30 °C / 60 °F ~ 86 °F
    Air temp (Heat) : 16 °C ~ 30 °C / 60 °F ~ 86 °F
    Air temp (Heat) : 16 °C ~ 30 °C / 60 °F ~ 86 °F
    Water temp(Heat) : 15 °C ~ 80 °C / 59 °F ~ 176 °F
    Water temp(Cool) : 6 °C ~ 25 °C / 42 °F ~ 77 °F
    Water temp(Heat) : 20 °C ~ 55 °C / 68 °F ~ 131 °F

    Hot water
    temp

    !

    Product type
    1) WHU[Hydrokit] : 30 °C ~ 50 °C / 86 °F ~ 122 °F
    2) SINGLE_AWHP : 30 °C ~ 80 °C / 86 °F ~ 176 °F
    3) CASCADE : 30 °C ~ 80 °C / 86 °F ~ 176 °F
    4) HEAT_ONLY_AWHP : 30 °C ~ 80 °C / 86 °F ~ 176 °F

    NOTE

    According to the product type, some additional functions may not be displayed or not operational.



  • Page 28

    28 HOW TO USE

    ENGLISH

    Schedule view
    This screen views the monthly/weekly/list of the schedule.
    The default schedule screen display is monthly.
    - Monthly view: You can see monthly set schedules at a glance.
    - Weekly view: You can see weekly set schedules at a glance.
    You can check the start time of the schedule and the set operation mode.
    - List view: You can check the entire set schedule list.
    You can check the number of equipment that will be operated in the set schedule.

    <Monthly view>

    <List view>

    <Weekly view>



  • Page 29

    HOW TO USE 29

    ENGLISH

    Add schedule
    1. Press the

    Add

    button.

    2. Input the basic schedule information.

    After the input, press

    Next

    <Name setting>

    <Date setting>

    <Time setting>

    <Repeat setting>

    button.



  • Page 30

    30 HOW TO USE

    ENGLISH

    3. Input additional equipment and detail setting values.

    <Select Air conditioner> <Setting value input screen>

    <Select Ventilation>

    <Setting value input screen>

    <Select Heating>

    4. When you press

    !

    Complete

    <Setting value input screen>

    button, the schedule is saved.

    NOTE

    If repeat pattern is set not to use, the set period is fixed to today's date. When ERV and ERV DX
    are selected at the same time, the ERV control screen is displayed.



  • Page 31

    HOW TO USE 31

    1. Select the schedule to edit.

    2. Press

    Edit

    button at the bottom.

    3. Change the basic schedule information.

    After the input, press

    Next

    <Name setting>

    <Date setting>

    <Time setting>

    <Repeat setting>

    button.

    ENGLISH

    Edit schedule



  • Page 32

    32 HOW TO USE

    ENGLISH

    4. Add equipment and change detail setting values.

    <Select Air conditioner> <Setting value input screen>

    <Select Ventilation>

    <Setting value input screen>

    <Select Heating>

    5. When you press

    Complete

    button, the schedule is saved.

    <Setting value input screen>



  • Page 33

    HOW TO USE 33

    ENGLISH

    Delete schedule
    1. Select the schedule to edit.

    3. In the whether to delete check screen, press

    4. The schedule is deleted.

    2. Press

    Apply

    Delete

    button.

    button at the bottom.



  • Page 34

    34 HOW TO USE

    ENGLISH

    View report
    This screen views the occurred error information, filter / oil change alarm information and energy
    information.
    - Error: Displays the error report.
    (You can view each error report of Air conditioner/Ventilation/Heating.)
    It displays [date / time / device name / error code / message] of the occurred error.
    When you select the error contents, you can check the detail error information.

    <View entire error report>

    <View detail error information>

    - Change alarm: It displays the occurred filter / oil change alarm report.
    It displays [date / time / device name / message] of the occurred alarm.
    When you select the alarm contents, you can check the detail change alarm information.

    <View entire change alarm report>

    <View detail change alarm information>



  • Page 35

    HOW TO USE 35

    !

    <View entire energy report>

    <View detail energy information of group>

    <View entire energy report>

    <View detail energy information of device>

    NOTE

    In slave state, you cannot use each equipment’s lock setting, set temp range, 2set point, IDU
    2set, auto search device function, energy report and energy save mode.

    ENGLISH

    - Energy: It displays the energy report.
    You can check the power consumption and accumulated power consumption of
    group / individual equipment.
    When you select the energy contents, you can check the detail energy information.



  • Page 36

    36 HOW TO USE

    ENGLISH

    Emergency stop
    <Occurrence of emergency stop situation>
    The emergency stop function is to stop all connected cooling and heating equipment when an
    emergency stop situation occurs.
    When there is an input to DI port, it stops all connected equipment and shows the emergency
    stop state as follows.

    AI+
    DI +
    COM -

    <Cancel emergency stop>
    When there is no input to DI port, you can cancel the emergency stop by pressing the emergency stop Cancel button.
    To cancel the emergency stop state, input the password and press Apply button.

    !

    NOTE

    If the password setting is “OFF”, you can cancel emergency stop without the password input.



  • Page 37

    HOW TO USE 37

    ENGLISH

    Setting

    Classification

    Detail control

    Operation setting

    Auto mode option, energy save mode cycle, temperature difference,
    holiday setting, schedule initialization

    Group setting

    Equipment group setting (for each Air conditioner/Ventilation/Heating)

    System
    setting

    General

    Date, time, daylight saving time, controller name, speaker,
    temperature display, language

    Advance

    Network, password, version information, open source license

    Screen setting

    Theme, screen saver, screen saver waiting time, monitor power waiting time, brightness

    Installer setting

    LGAP setting, language update, device management



  • Page 38

    38 HOW TO USE

    ENGLISH

    Operation setting

    <Auto mode option setting>
    Auto mode option is set to auto mode and 2set auto mode.
    Auto mode supports the setting function for the auto conversion operation and temperature limit
    operation.
    2set auto mode supports the setting function for advanced setting.
    (When it is in the auto mode, in the detail control screen, you can select whether to use the auto
    change over / setback. In 2set auto mode, you can select occupied/unoccupied.)

    <Energy save mode cycle setting>
    It is the function for power saving, and you can set the Energy save mode cycle [5 minutes / 10
    minutes / 15 minutes].



  • Page 39

    HOW TO USE 39

    When the energy save mode icon is turned on, the [Energy save mode] icon is lighted in green.

    <Temperature difference setting>
    When the central auto control operation function is on, you can set the temperature difference.

    - Celsius : You can set in 0.5 °C unit from 0.5 °C ~ 3.0 °C
    Fahrenheit : You can set in 1.0 °F unit from 1.0 °F ~ 6.0 °F

    ENGLISH

    When you press
    in the Aircon control screen, the air conditioner energy save mode is turned
    on, and it repeats the operation state change control in sequence according to the set energy
    save mode cycle.
    h Energy save mode operates the air conditioner only.
    - In cooling operation: Cool ↔ Fan, lock all
    - In heating operation: Heat ↔ OFF, lock all



  • Page 40

    40 HOW TO USE

    ENGLISH

    <Holiday setting>
    You can set the exception date not to apply the schedule.

    Setting up the exceptional date is applicable only to the corresponding year.
    1) Add exception date
    Add button to enter the addition screen.
    - Press
    - After the input of the name and date of the exception date to add, press Apply button.

    2) Edit exception date
    - After selecting the exception date to edit from the
    list, press
    Edit button.
    - After changing the exception date name and date,
    press Apply button.

    3) Delete exception date
    - After selecting the exception date to delete from
    the list, press Delete button.

    <Schedule initialization>
    All currently set schedules are deleted.



  • Page 41

    HOW TO USE 41

    ENGLISH

    Group setting
    You can add a new group to manage, or edit or delete existing indoor unit group.
    <Add group>
    1. In the group setting screen, select the
    equipment group to add
    (Air conditioner/Ventilation/Heating).
    2. Press Edit button at the top to enter the
    edit mode.

    3. Select

    4. In the 1st stage after entering the group
    add screen, input the group name and
    press Next button at the top.

    5. In the 2nd stage, select the equipment to
    add to the group. (You can select several
    equipment.)
    6. Press Complete button at the top.

    7. It displays the phrase saying that group addition is completed, and the added group
    appears.

    Add

    button.



  • Page 42

    42 HOW TO USE

    ENGLISH

    <Edit group>
    1. In the group setting screen, select the
    equipment group (Air conditioner/Ventilation/Heating) to edit and select the group
    to change in the group list.

    2. Select

    3. Change the group name, and press
    Next
    button.

    4. Select the equipment to add to the corresponding group.
    (You can select several equipment.)

    If you do not change the group name,
    directly press Next button.

    6. It displays the phrase saying that the group
    edition is completed, and the edited contents are reflected.

    5. Press

    Edit

    Complete

    button.

    button at the top.



  • Page 43

    HOW TO USE 43

    1. In the group setting screen, select the
    equipment group (Air conditioner/Ventilation/Heating) to delete from the group.
    2. Press Edit button at the top to enter
    the edit mode.

    3. Select the group to delete and press
    button.
    Del

    4. In the group deletion verification window, press Apply button.

    5. It displays the phrase saying that group
    deletion is completed, and the corresponding group is deleted.

    ENGLISH

    <Delete group>



  • Page 44

    44 HOW TO USE

    ENGLISH

    System setting
    The system setting is divided to general setting / advanced setting.

    <General setting>

    <Advanced setting>

    - In the general setting, you can set the time, date, daylight saving time, controller name,
    speaker, temperature display, and language.
    - In the advanced setting, you can set the network and password, and it displays the version information, open source license.



  • Page 45

    HOW TO USE 45

    <Date setting>
    In this screen, you can set the current date. After the input of the year / month / day input to
    set, press Apply button.

    h When you change the current date value, the standard date is changed, and the displayed
    date and schedule interface date, etc. will be operated based on the set date.
    <Time setting>
    In this screen, you can set the current time. After the input of the AM/PM / hour / minute to
    set, press Apply button.

    h When you change the current time value, the standard time is changed, and the displayed
    time and schedule interface time, etc. will be operated based on the set time.
    <Daylight saving time setting>
    In this screen, you can set the date and time to start/end daylight saving time. If the system
    date/time is reached at the daylight saving time start time, it operates by adding one hour
    from the current time. Conversely, if the system date/time is reached at the daylight saving
    time end time, it operates by subtracting one hour from the current time.

    ENGLISH

    System setting (General setting)



  • Page 46

    46 HOW TO USE

    ENGLISH

    <Controller name setting>
    In this screen, you can set the name of the currently used controller. After the controller name
    input, press Apply button.

    The set name is displayed at the top left side of the home screen.

    <Speaker setting>
    In this screen, you can set whether to use the speaker.

    !

    NOTE

    The speaker set-up function is not supported on the PC.



  • Page 47

    HOW TO USE 47

    <Celsius>

    <Fahrenheit>

    When Celsius is selected, °C minimum temperature display is activated, and please select
    whether to set the temperature unit to 0.5° or 1.0°.

    <Language setting>
    In this screen, you can set the language to display on the controller. Select the language to use,
    and press Apply button.

    ENGLISH

    <Temperature display setting>
    In this screen, it sets whether to display the temperature in Celsius or Fahrenheit. Select Celsius
    / Fahrenheit.



  • Page 48

    48 HOW TO USE

    ENGLISH

    System setting (Advanced setting)
    <Network setting>
    In this screen, you can save or change the network setting information to use when you wish to
    connect to ethernet.
    1) IP address setting
    IP address setting methods are using DHCP to get IP address and designating IP address.

    - Get the IP address using DHCP
    You can use DHCP to automatically set dynamic IP in the currently connected internet network.
    (If it is DHCP, IP information setting category is deactivated.)

    - Using static IP address
    You can set the network using the user input IP information. If you select the IP address
    designation, IP information is activated, and you can input the IP information.



  • Page 49

    HOW TO USE 49

    3) HTTP port designation
    You can change HTTP port setting information for the ethernet connection (for service).
    User can freely set HTTP port according to the network environment.
    (Input boundary is 1~65535.)

    ENGLISH

    2) DNS server designation
    You can set main DNS / sub DNS address.



  • Page 50

    50 HOW TO USE

    ENGLISH

    <Password setting>
    In this screen, you can initialize or change the password, and when you enter the setting screen,
    you can set whether to use password.
    1. If password is used
    1) Select to use the password.

    3) It displays that the password is set, and
    the password is displayed as used.
    You need to press Apply button to finally apply the set password.

    2. When you change the password
    1) Select password change.

    2) Input the previously set password, and
    press Apply button.

    4) It displays that the password set-up is
    completed.

    2) Input the current password and the new
    password, and press Apply button.



  • Page 51

    HOW TO USE 51

    3. If you do not use the password
    1) Select password usage.

    4) It displays that the password set-up is
    completed.

    2) It displays that the password is cleared,
    and the password is displayed as not
    used. You need to press Apply button to
    apply password not used.

    3) It displays that the password set-up is completed.

    ENGLISH

    3) It displays that the password is set, and
    the password is displayed as used.
    You need to press Apply button to
    apply the changed password.



  • Page 52

    52 HOW TO USE

    ENGLISH

    4. In case of wrong password input,
    1) In case of wrong password input, it displays the phrase saying that the password input
    is wrong as follows.
    2) In case of 5 repeated wrong password input, it verifies whether to initialize the password.
    When you press Cancel button, the password input screen appears again.
    h For the password initialization, please contact the installation store or service center.

    <In case of wrong password input>

    <In case of 5 repeated wrong password input>

    <Version information & SW update>
    In this screen, it displays the current version information of the controller.

    h Update function is an installer and service function.

    <Open source license>
    This screen displays a open source license notice of AC Ez Touch.



  • Page 53

    HOW TO USE 53

    <Theme setting>
    In this screen, you can select white / black theme according to the usage environment.
    Select the desired theme, and press Apply button.

    <Screen saver setting>
    In this screen, it sets the screen saver to display on the screen.
    Select whether to use screen saver / guide word button / screen saver preview button, and
    press Apply button.
    1) Screen saver setting

    2) Screen saver guide edit
    Input the phrase to display at the bottom
    of the screen saver, and press Apply
    button.

    3) Screen saver preview
    In this screen, you can preview the screen
    saver.

    ENGLISH

    Screen setting



  • Page 54

    54 HOW TO USE

    ENGLISH

    !

    NOTE

    If the monitor power standby time is the same as the screen saver standby time or shorter, the
    monitor power is turned off.

    <Screen saver waiting time setting>
    It sets the standby time before displaying the screen saver when there is no input.
    → Screen saver standby time [1 minute / 5 minutes / 10 minutes]
    Select the screen saver standby time, and press Apply button.

    <Monitor power waiting time setting>
    It sets the standby time before turning off the screen when there is no input.
    → Monitor power standby time [1 minute / 5 minutes / 10 minutes / OFF]
    Select the monitor power standby time, and press Apply button.

    While the monitor power is turned off, when you touch the screen, it displays the screen again.



  • Page 55

    HOW TO USE 55

    In this screen, you can set the brightness of the screen according to the ambient illumination.
    → Screen brightness selection [25%, 50%, 75%, 100%]
    Select the screen brightness, and press Apply button.

    !

    NOTE

    The screen brightness set-up function is not supported on the PC.

    ENGLISH

    <Screen brightness setting>



  • Page 56

    56 HOW TO USE

    ENGLISH

    Installer setting
    <LGAP setting>
    In this screen, you can set Master / Slave according to the interface status to the central controller.

    If the one AC Ez Touch is installed without other central controller, set to Master.

    !

    NOTE

    In slave state, you cannot use each equipment’s lock setting, set temp range, 2set point, IDU
    2set, auto search device function, energy report and energy save mode.

    <Language update (for service)>
    This screen is the function to update language when multi-language needs to be applied.

    h Language update function is for service.



  • Page 57

    HOW TO USE 57

    In this screen, you can search registered device and register the searched device to the device
    management list. At this time, device that can be searched is Air conditioner/Ventilation/Heating.
    1. Auto registration function
    1) To automatically search the connected device, press Auto button.
    2) To run the auto device registration, check the following cautions, and then press
    OK
    button.

    3) When the search is completed, it displays the number of searched indoor units. To register
    the searched device, press Apply button.

    4) The searched device is added to the list. To complete the device registration, press
    Complete button.

    !

    NOTE

    In slave state, you cannot use each equipment’s lock setting, set temp range, 2set point, IDU
    2set, auto search device function, energy report and energy save mode.

    ENGLISH

    <Device management>



  • Page 58

    58 HOW TO USE

    ENGLISH

    5) It checks whether to lock the address of the indoor unit so that general user may not
    change the set indoor unit address without authorization. To set the indoor unit address
    lock, press Yes button, and if you do not set, press No button.

    6) It displays the phrase saying that the device information is updated, and it displays the
    number of registered device.



  • Page 59

    HOW TO USE 59

    2) Press

    Add

    button at the top.

    3) Input the detail information of the device to add.
    (device type, device name, address,
    model, capacity)
    4) Press Apply button.

    5) It enters the device management screen.

    7) It checks whether to lock the device address so that general user may not
    change the set device address without
    authorization.

    8) It displays the phrase saying that the device information is updated, and it displays
    the number of registered device.

    To lock the device address, press
    button, and when you do not set,
    Yes
    press No button.

    6) To reflect the device addition, press
    Complete button.

    ENGLISH

    2. Manual registration function
    1) Press Edit button at the top.



  • Page 60

    60 HOW TO USE

    ENGLISH

    3. Manual edit function
    1) Select the device to edit in the device
    management list.

    2) Press Edit button in the detail device information screen.

    3) Input the detail information of the device to edit.
    (device type, device name, address,
    model, capacity)
    4) Press Apply button.

    5) It enters the device management screen.

    7) It checks whether to lock the device address so that general user may not
    change the set device address without
    authorization.

    8) It displays the phrase saying that the device information is updated, and it displays
    the number of registered device.

    To lock the device address, press
    button, and when you do not set,
    Yes
    press No button.

    6) To reflect the device edition, press
    Complete button.



  • Page 61

    HOW TO USE 61

    4) To proceed with the delete, press
    button.

    2) Select the device to delete.
    3) Press Del button at the top.

    Apply

    7) It checks whether to lock the device address so that general user may not
    change the set device address without
    authorization.
    To lock the device address, press
    button, and when you do not set,
    Yes
    press No button.

    5) It enters the device management screen.
    6) To reflect the device deletion, press
    Complete button.

    8) It displays the phrase saying that the device information is updated, and it displays
    the number of registered device.

    ENGLISH

    4. Device delete function
    1) Press Edit button at the top.



  • Page 62

    62 HOW TO USE

    ENGLISH

    PC access
    It supports the function that you can control and monitor connected devices via the web application.
    1. Set the IP in the network setting screen.

    2. Connect by entering the IP set in the web
    browser. Click the download link.

    3. Install the program.

    4. Run the installed program.

    5. Enter the Name and IP.
    Click on the “Setup" button.
    (Enter the name after ‘ACEzTouch_’)

    6. Connected.

    123.456.789.100

    <Requirements>
    Hardware
    CPU
    Main memory
    Hard disk
    Main OS

    Dual core 2.4GHz or more
    4GB or more
    At least 1GB of free space on the disk
    Windows XP/7/8/8.1/10 (32/64bits)



  • Page 63

    HOW TO USE 63

    In this chapter, it describes the installation and setting method to set AC Ez Touch.
    To use AC Ez Touch, you need to establish the environment for the controller and the equipment (Air conditioner/Ventilation/Heating) to communicate with each other, and you need to register the corresponding equipment through AC Ez Touch.
    You need to install in the following order.

    Step 1 : Installation environment check and setting up the equipment address
    Before installing AC Ez Touch, check the network composition with the interfaced equipment, and assign address that does not overlap on the connected equipment.

    Step 2 : Product installation and RS485 communication connection
    Install AC Ez Touch and connect RS-485 communication cable.

    Step 3 : Connecting cables and power adapter
    Connect network and other cables, and then connect the power adapter.

    Step 4 : Air conditioner/Ventilation/Heating equipment registration and group set-up
    Register the connected air conditioner, ventilation and heating equipment, and set the group.

    Step 5 : Operation
    Check if basic control and the set up contents work normally.

    ! CAUTION
    • Installation work requires specialized technology. Therefore, the installation contents
    mentioned in this chapter must be carried out by a qualified installation technician.
    • If you have questions or requests related to the installation, please contact the service
    center or specialist installation company acknowledged by LG Electronics.

    ENGLISH

    Installation and setting



  • Page 64

    64 HOW TO USE

    ENGLISH

    Installation environment check and setting up the equipment address
    Power Distribution
    Indicator (PDI)

    Outdoor unit
    Indoor unit 1

    Setting
    address
    01
    Outdoor unit

    Indoor unit 1

    Setting
    address
    04

    Indoor unit 2

    Setting
    address
    02
    Indoor unit 2

    Setting
    address
    05

    Indoor unit 3

    Setting
    address
    03
    Indoor unit 3

    Setting
    address
    06

    ERV
    Setting
    address
    11
    PI485

    ERV
    Setting
    address
    12
    PI485

    Heating
    Setting
    Address
    31
    PI485

    ...

    !

    NOTE

    • The maximum communication distance guaranteed by LG Electronics is 1 000 m. That is, the
    equipment installed at the farthest location from AC Ez Touch shall be within 1 000 m.
    • It is recommended to use the communication cable of 0.75 mm2 or more.
    • Set a unique address, that does not overlap with other equipment on the same bus.
    • Each device which can be used with PDI must be set to a unique address when connected
    with PDI. For further information about the devices can be used with PDI, please refer to the
    PDI manual.



  • Page 65

    HOW TO USE 65

    Maximum of 64 indoor units can be connected to one AC Ez Touch. If multiple number of the
    outdoor units need to be connected, the connection should be in BUS type. Otherwise, AC Ez
    Touch may malfunction.

    <Correct example :
    RS485 BUS-type connection>

    <Incorrect example :
    RS485 STAR-type connection>

    ENGLISH

    <RS485 communication cable connection>



  • Page 66

    66 HOW TO USE

    ENGLISH

    Central control address of the indoor unit set-up
    First, you need to assign address that does not overlap with other equipment (Air-conditioner/Ventilation/Heating equipment) considering the entire installation composition connected to one AC Ez Touch.
    The equipment address can be set in hexadecimal from 00 to FF.

    !

    NOTE

    Outdoor unit and indoor unit number assignment
    If the outdoor unit product is Multi V, it is recommended
    to set the first digit of the address as the outdoor unit
    number, and set the second digit as the indoor unit
    number, so that the system composition and division
    can be easily identified during the address setting.

    !

    Outdoor unit
    (group) number

    Indoor unit
    number

    NOTE

    Indoor unit central control address setting
    The central control address setting method may be different according to the indoor unit product
    or remote controller type, so set the address by referring to the indoor unit product or wired remote controller manual.



  • Page 67

    HOW TO USE 67

    The installation and cable connection methods of AC Ez Touch are as follows.
    1. Decide the space to install the controller.
    - Before fixing the controller to the wall, check if it is a suitable location to connect the controller, RS485 cable, power cable, and ethernet cable.
    - Determine the wiring direction of the product, and remove the knockout structure of the corresponding direction.
    * Method of removing the knockout structure
    ① Cut the rim of the groove part on the both
    sides of the knockout structure using a
    nipper.

    ② After cutting, bend the knockout structure to
    the inward direction & outward director for 2
    times, respectively.

    ③ Tear the knockout structure.

    !

    NOTE

    Make sure to use a nipper as tool. When
    using other tools such as pincers, a sharp
    cutting trail remains on the cut surface,
    and scratch or notches by the electricwire may occur.

    <when using a nipper>

    <when using a pincers>

    ENGLISH

    <Installing the product>



  • Page 68

    68 HOW TO USE

    ENGLISH

    2. Fix the controller's wall installation plate to the wall above RS485 cable.

    3. Connect RS485 cable located at the backside of the controller main unit to RS485 connector.

    When connecting T/B, after removing the sheath referring to the guide as shown on the
    picture, make sure to connect by inserting a short-protecting sleeve into the O-ring or U-terminal.
    mm ±3mm
    10

    ±5

    45

    GN

    /YL
    20
    mm

    <Sheath-removal guide>

    sleeve O-ring
    <Shape of applying to O-ring and sleeve>

    ! CAUTION
    • Be careful not to cross wire connections. RS485 communications are dependant on correct polarity.
    • When the cable is connected in reclamation structure, be careful of the bending of RS485
    communication cable.



  • Page 69

    HOW TO USE 69

    5. Connect power adaptor to the power connector located at the backside of the controller main
    unit.

    ENGLISH

    4. If network connection is required from the controller, connect the ethernet cable to LAN port
    at the backside of the controller main unit.



  • Page 70

    70 HOW TO USE

    ENGLISH

    6. After matching the hook of the wall mounting plate installed on the wall and the groove of
    the product, push the product to match the groove.

    <Groove of the product>

    <Wall-mounting plate hook>

    7. Push down the product to lock the top hook.

    !

    NOTE

    Seperation sequence is in reverse of installation sequence.

    8. Connect the power cord of the power adapter of the power plug.



  • Page 71

    HOW TO USE 71

    AC Ez Touch has an emergency stop function to stop all connected equipment (Airconditioner/Ventilation/Heating equipment) when there is an emergency in the building.
    When DI port detects a short circuit signal, AC Ez Touch stops the operations of all connected
    equipment.
    Regarding emergency stop function, it can be used by connecting to the DI port of external powerless contact type on the rear of AC Ez Touch as shown below.

    AI+
    DI +
    COM -

    !

    NOTE

    DI port shall always be in open state except the emergency situation.

    ENGLISH

    <Emergency stop function set-up>



  • Page 72

    72 HOW TO USE

    ENGLISH

    Check list before calling for service
    When any malfunction occurs to the product, check the following list before contacting the service center.
    Symptoms

    Check

    All products keep
    turning off.

    Is the DI port in 'short' status?

    Product is reset in
    the middle of a
    night.

    It is automatically reset at
    AM 2:05 every Monday.

    Equipment is not
    controlled.

    Is the equipment in ‘locked’
    status?

    Error display apIs the equipments with the
    pears on the equip- error message connected
    ment icon.
    properly?

    Action
    Change DI port state to open state.
    (If DI port is in short circuit state, operations
    of all connected equipment stop.)

    Check if lock function is set, and clear the
    lock function.
    If the equipment are not properly connected,
    error is displayed.
    Check the equipment connection status.

    Lock cannot be set.
    Cannot use temperature limit setting. Is the product set up as
    'Slave' status?
    Cannot user auto
    search device function.

    In slave state, you cannot use each equipment’s lock setting, set temp range, 2set
    point, IDU 2set, auto search device function,
    energy report and energy save mode.

    PC program is stop. -

    After exiting the running program, try again.

    Time is changed
    without setting
    manually.

    Please turn off daylight saving time.

    Is daylight saving time set?

    Guide to open source software
    If you want to obtain GPL, LGPL, MPL and other source codes developed under open source
    license, visit http://opensource.lge.com.
    You can download all the contents of the relevant license including source code, copyright
    marking and marking which represents there is no guaranteed liability.
    If you request open source code of the software installed in this product by sending e-mail to
    opensource@lge.com within 3 years from the purchase of the product, it will be provided in
    CD-ROM with minimum fee for media, transportation, etc.



  • Page 73

    ver. 1.0.3






Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für LG CACEZA000 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Holen Sie sich Ihr Benutzerhandbuch per E-Mail

Geben Sie Ihre E-Mail-Adresse ein, um das Handbuch zu erhalten von LG CACEZA000 in der Sprache / Sprachen: Englisch als Anhang in Ihrer E-Mail.

Das Handbuch ist 16,5 mb groß.

 

Sie erhalten das Handbuch in Ihrer E-Mail innerhalb von Minuten. Wenn Sie keine E-Mail erhalten haben, haben Sie wahrscheinlich die falsche E-Mail-Adresse eingegeben oder Ihre Mailbox ist zu voll. Darüber hinaus kann es sein, dass Ihr ISP eine maximale Größe für E-Mails empfangen kann.

Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info