FUNCTION SETTING
72
FUNCTION SETTING
ENGLISH
Function Setting Vane angle control setting
You can control the wind blowing angle.
- In the function setting list screen, press [,(up/down)] button to select the vane angle control
category, and press [OK] button to move to the up/down vane angle detail screen.
• In the detail screen, press [,(up/down)] button to select “individual control, overall control,
standard”.
• Use [<,>(left/right)] button to select the vane.
- The selected vane is moving. Check the moving vane.
• Press [,(up/down)] button to select the desired wind angle, and press [OK] button to save
the setting.
- The wind angle’s setting range can be changed to 5 stages or 6 stages according to the prod-
uct.
If you do not press [OK] button, the selected wind angle will not be reflected.
OK
NOTE
!
For some product types, there are products with only 1 or 2 vanes.
Control Description
Each It sets the vane angle individually.
All It sets the vane angle of all the vanes of the product at once.
Standard It sets the vane angle to the factory initialization state.
Menu Description
Vane angle control setting
You can control the wind blowing angle.
Elevation grill setting
It is the function to operate the Elevation grill for the indoor unit filter cleaning.
Robot cleaning setting
Robot cleaning function is the function to automatically perform the filter
cleaning with the cleaner of the product when the air conditioner is used for
certain time period. It sets the manual or automatic operation of the robot
cleaning. You can set it 30 seconds after the stopping of the operation.
Auto dry setting
Auto dry function is the function to remove mold and moisture by dry-
ing the inside of the indoor unit after the cooling operation and when
the product is turned off.
Filter sign check and ini-
tialization
When it becomes the time for the indoor unit filter cleaning, the filter
cleaning display appears, and it is the function to remove the display.
Change Temperature
setting
Change Temperature is the function to set the temperature for the au-
tomatic conversion between cooling and heating according to the
temperature in AI operation mode.
Dead Band
When heating and cooling desired temperatures have been changed,
the set value will maintain a difference between the heating and cool-
ing desired temperature.
Wi-Fi pairing
It is the function to perform the pairing function of the Wi-Fi module
connected to the indoor.
Zone Name setting Zone name settings allow you to select zone name.
Override set time setting When timed override is used, the set time will be a default value.
Home leave set temper-
ature setting
When customer operate as home leave mode, this setting tempera-
ture value will be applied.
Comfort cooling setting
It is the function to set the outdoor unit Comfort saving operation
stage value.
ODU Refrigerant Noise
Reduction setting
It is the function to set the outdoor unit’s refrigerant noise reduction
function.
Defrost Mode setting It is the function to set the outdoor unit’s defrost mode operation.
Smart load control
setting
It is the function to set the outdoor unit’s smart load control stage value.
(Smart load control is the function to calculate the necessary performance
with the indoor and outdoor air temperature and humidity and operate.)
Low noise mode time
setting
It is the function to set the start and end time of the outdoor unit’s
low noise mode operation.
Advanced fan speed “Auto”
It is the function to set the indoor unit’s fan auto by temperature.
Delay time setting (ex-
clusive for ventilation)
It is the function to set the ventilation operation to start after the delay
time.
Midnight air cooling
(ventilation interface)
It is the function to discharge indoor air and supply cool outdoor air
into the indoor during summer nights to save energy.
Human detection mode It is the function to set the operation of human detection mode.
Discharge direction
This is a function to set the usage of the upper and lower vanes when
operating the product.
CO2 fan control
A function that controls the fan when the product is turned ON/OFF,
based on the CO2 concentration in the ventilation product.
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 72
37

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für LG PREMTBB10 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von LG PREMTBB10

LG PREMTBB10 Bedienungsanleitung - Deutsch - 84 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info