Zoom out
Zoom in
Vorherige Seite
1/21
Nächste Seite
ENGLISH
LG
Air Conditioner
OWNER'S MANUAL
LG
IMPORTANT
• Please read this owner's manual carefully and thoroughly
before installing and operating your room air conditioner.
• Please retain this owner's manual for future reference after
reading it thoroughly.
Type : Convertible
êÛÒÒÍËÈ
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Inhalt der Seiten


  • Page 1

    OWNER'S MANUAL
    Type : Convertible

    IMPORTANT
    • Please read this owner's manual carefully and thoroughly
    before installing and operating your room air conditioner.
    • Please retain this owner's manual for future reference after
    reading it thoroughly.

    êÛÒÒÍËÈ

    LG
    Air Conditioner

    ENGLISH

    LG



  • Page 2

    Convertible Air Conditioner Owner’s Manual

    TABLE OF CONTENTS
    FOR YOUR RECORDS
    Safety Precautions.................3

    Write the model and serial numbers here:
    Model #

    Prior to operation ...................6
    Operating Instructions...........7

    Serial #
    You can find them on a label on the side of each unit.
    Dealer's Name
    Date Purchased

    Additional features...............14

    ■ Staple your receipt to this page in the event you need it
    to prove date of purchase or for warranty issues.

    Maintenance and Service ....18

    READ THIS MANUAL
    Inside you will find many helpful hints on how to use and
    maintain your air conditioner properly. Just a little
    preventive care on your part can save you a great deal
    of time and money over the life of your air conditioner.
    You'll find many answers to common problems in the
    chart of troubleshooting tips. If you review our chart of
    Troubleshooting Tips first, you may not need to call for
    service at all.

    PRECAUTION
    • Contact the authorized service technician for repair or
    maintenance of this unit.
    • Contact the installer for installation of this unit.
    • The air conditioner is not intended for use by young
    children or invalids without supervision.
    • Young children should be supervised to ensure that
    they do not play with the air conditioner.
    • When the power cord is to be replaced, replacement
    work shall be performed by authorized personnel only
    using only genuine replacement parts.
    • Installation work must be performed in accordance
    with the National Electric Code by qualified and
    authorized personnel only.

    2 Convertible Air conditioner



  • Page 3

    Safety Precautions

    Safety Precautions

    WARNING

    This symbol indicates the possibility of death or serious injury.

    CAUTION

    This symbol indicates the possibility of injury or damage to properties only.

    ■ Meanings of symbols used in this manual are as shown below.

    Be sure not to do.
    Be sure to follow the instruction.

    ■ Installation
    Do not use a defective or
    underrated circuit breaker.
    Use this appliance on a
    dedicated circuit.

    WARNING
    For electrical work, contact
    the dealer, seller, a qualified
    electrician, or an Authorized
    Service Center.

    • There is risk of fire or electric
    shock.

    • Do not disassemble or repair the product.
    There is risk of fire or electric shock.

    Install the panel and the
    cover of control box
    securely.

    Always install a dedicated
    circuit and breaker.

    • There is risk of fire or electric
    shock.

    • Improper wiring or installation
    may cause fire or electric shock

    Do not modify or extend the
    power cable.
    • There is risk of fire or electric
    shock.

    For installation, always contact the
    dealer or an Authorized Service Center.
    • There is risk of fire, electric
    shock, explosion, or injury.

    Do not install, remove, or
    re-install the unit by
    yourself (customer).
    • There is risk of fire, electric
    shock, explosion, or injury.

    Do not install the product on
    a defective installation stand.
    • It may cause injury, accident, or
    damage to the product.

    Always ground the product.

    • There is risk of fire or electric
    shock.

    Use the correctly rated
    breaker or fuse.
    • There is risk of fire or electric
    shock.

    Be cautious when
    unpacking and installing
    the product.
    • Sharp edges could cause injury.
    Be especially careful of the
    case edges and the fins on the
    condenser and evaporator.

    Be sure the installation area
    does not deteriorate with age.
    • If the base collapses, the air
    conditioner could fall with it,
    causing property damage,
    product failure, and personal
    injury.

    Owner's Manual 3

    ENGLISH

    To prevent injury to the user or other people and property damage, the following instructions must be
    followed.
    ■ Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified
    by the following indications.



  • Page 4

    Safety Precautions

    ■ Operation
    Do not let the air conditioner run for a
    long time when the humidity is very high
    and a door or a window is left open.
    • Moisture may condense and
    wet or damage furniture.

    Take care to ensure that power
    cable could not be pulled out
    or damaged during operation.

    Do not place anything on
    the power cable.

    • There is risk of fire or electric
    shock.

    • There is risk of fire or electric
    shock.

    Do not touch(operate) the
    product with wet hands.

    Do not place a heater or
    other appliances near the
    power cable.

    • There is risk of fire or electric
    shock.

    • There is risk of fire or electrical
    shock.

    • There is risk of fire and electric
    shock.

    Do not allow water to run
    into electric parts.

    Do not store or use flammable
    gas or combustibles near the
    product.

    Do not use the product in a
    tightly closed space for a
    long time.

    • It may cause There is risk of
    fire, failure of the product, or
    electric shock.

    • There is risk of fire or failure of
    product.

    • Oxygen deficiency could occur.

    Do not plug or unplug the
    power supply plug during
    operation.

    When flammable gas leaks,
    turn off the gas and open a
    window for ventilation
    before turn the product on.

    If strange sounds, or small or
    smoke comes from product. Turn
    the breaker off or disconnect the
    power supply cable.

    • Do not use the telephone or
    turn switches on or off.
    There is risk of explosion or fire

    • There is risk of electric shock or
    fire.

    Do not open the inlet grill of the
    product during operation.
    (Do not touch the electrostatic
    filter, if the unit is so equipped.)
    • There is risk of physical injury,
    electric shock, or product
    failure.

    When the product is soaked
    (flooded or submerged),
    contact an Authorized
    Service Center.
    • There is risk of fire or electric
    shock.

    Ventilate the product from time to time
    when operating it together with a stove, etc.
    • There is risk of fire or electric shock.

    When the product is not be used for a long
    time, disconnect the power supply plug or
    turn off the breaker.
    • There is risk of product damage or failure, or
    unintended operation.

    4 Convertible Air conditioner

    Stop operation and close the window
    in storm or hurricane. If possible,
    remove the product from the window
    before the hurricane arrives.
    • There is risk of property
    damage, failure of product, or
    electric shock.

    Be cautious that water
    could not enter the product.

    • There is risk of fire, electric
    shock, or product damage.

    Turn the main power off when cleaning or
    maintaining the product.
    • There is risk of electric shock.

    Take care to ensure that nobody could step
    on or fall onto the outdoor unit.
    • This could result in personal injury and product
    damage.



  • Page 5

    Safety Precautions

    CAUTION
    ■ Installation

    • Low refrigerant levels may
    cause failure of product.

    Do not install the product where the
    noise or hot air from the outdoor unit
    could damage the neighborhoods.
    • It may cause a problem for your
    neighbors.

    Install the drain hose to ensure
    that water is drained away
    properly.
    • A bad connection may cause
    water leakage.

    Use two or more people to lift
    and transport the product.
    • Avoid personal injury.

    Keep level even when
    installing the product.
    • To avoid vibration or water
    leakage.

    Do not install the product
    where it will be exposed to
    sea wind (salt spray) directly.
    • It may cause corrosion on the product. Corrosion,
    particularly on the condenser and evaporator fins, could
    cause product malfunction or inefficient operation.

    ■ Operation
    Do not expose the skin directly to cool air
    for long periods of time.
    (Don't sit in the draft.)
    • This could harm to your health.

    Do not use the product for special purposes, such as
    preserving foods, works of art, etc. It is a consumer
    air conditioner, not a precision refrigeration system.
    • There is risk of damage or loss of property.

    Do not block the inlet or
    outlet of air flow.

    Use a soft cloth to clean. Do
    not use harsh detergents,
    solvents, etc.

    • It may cause product failure.

    • There is risk of fire, electric shock, or
    damage to the plastic parts of the product.

    • There is risk of personal injury.

    Do not step on or put
    anyting on the product.
    (outdoor units)

    Always insert the filter
    securely. Clean the filter
    every two weeks or more
    often if necessary.

    Do not insert hands or other
    objects through the air inlet
    or outlet while the product
    is operated.

    • There is risk of personal injury
    and failure of product.

    • A dirty filter reduces the efficiency of
    the air conditioner and could cause
    product malfunction or damage.

    Do not drink the water
    drained from the product.

    Use a firm stool or ladder
    when cleaning or
    maintaining the product.

    • It is not sanitary and could
    cause serious health issues.

    Do not recharge or
    disassemble the batteries.
    Do not dispose of batteries
    in a fire.
    • They may burn or explode.

    • Be careful and avoid personal
    injury.

    If the liquid from the batteries gets
    onto your skin or clothes, wash it
    well with clean water. Do not use the
    remote if the batteries have leaked.
    • The chemicals in batteries could
    cause burns or other health
    hazards.

    Do not touch the metal parts of
    the product when removing the
    air filter. They are very sharp!

    • There are sharp and moving
    parts that could cause personal
    injury.

    Replace the all batteries in the remote
    control with new ones of the same
    type. Do not mix old and new batteries
    or different types of batteries.
    • There is risk of fire or explosion

    If you eat the liquid from the
    batteries, brush your teeth and
    see doctor. Do not use the remote
    if the batteries have leaked.
    • The chemicals could cause
    burns or other health hazards.

    Owner's Manual 5

    ENGLISH

    Always check for gas
    (refrigerant) leakage after
    installation or repair of product.



  • Page 6

    Prior to operation

    Prior to operation
    Preparing for operation
    1. Contact an installation specialist for installation.
    2. Connect the power cable between indoor unit and outdoor unit properly.
    3. Use a dedicated circuit.
    4. If the cord/plug is damaged, replace it with only an authorized replacement part.

    Usage
    1. Being exposed to direct airflow for an extended period of time could be hazardous to your health.
    Do not expose occupants, pets, or plants to direct airflow for extended periods of time.
    2. Due to the possibility of oxygen deficiency, ventilate the room when used together with stoves or
    other heating devices.
    3. Do not use this air conditioner for non-specified special purposes (e.g. preserving precision devices,
    food, pets, plants, and art objects). Such usage could damage the items.

    Cleaning and maintenance
    1. Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling
    sharp metal edges.
    2. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation,
    leading to possible electric shock.
    3. When cleaning the unit, first make sure that the power and breaker are turned off. There is a
    possibility of injury if the unit’s power is accidentally triggered on while cleaning inner parts of the
    unit.

    Service
    For repair and maintenance, contact your authorized service dealer.

    Symbols Used in this Manual
    This symbol alerts you to the risk of electric shock.
    This symbol alerts you to hazards that could cause harm to the
    air conditioner.

    NOTICE

    This symbol indicates special notes.

    6 Convertible Air conditioner



  • Page 7

    Operating Instructions

    Operating Instructions
    Remote Controller
    ENGLISH

    1. Remove the battery cover by pulling it according to the arrow
    direction.
    2. Insert new batteries making sure that the (+) and (-) of battery are
    installed correctly.
    3. Reattach the cover by sliding it back into position.

    NOTICE
    : Use 2 AAA(1.5volt) batteries. Do not use rechargeable batteries.

    Storage and Tips For Using the Remote Controller
    • The remote controller may be stored by mounting it
    on a wall.

    • To operate the room air conditioner, aim the Remote
    Controller to the signal receptor.

    R

    Signal Receptor
    Receives the signals from the remote controller.(Signal receiving sound: two short beeps or one long beep.)

    Operation Indication Lamps
    Operation indication lamps

    On/Off

    : Lights up during the system operation.

    Filter Sign

    : Lights up after 2400 hours from the time of first
    operating unit.
    : Lights up during Timer operation.

    Timer
    Defrost Mode

    : Lights up during Defrost Mode or
    Hot Start operation.(Heat pump model only)

    Outdoor unit
    operation

    : Lights up during outdoor unit operation.
    (Cooling model only)

    Owner's Manual 7



  • Page 8

    Operating Instructions

    Remote Control Operation
    The Remote Control transmits the signals to the system.

    - Features of the Remote Control- Door Closed

    Heat pump model
    Cooling model

    2
    4

    1
    3

    Flip-up door(closed)

    1 START/STOP BUTTON
    Operation starts when this button is pressed and
    stops when the button is pressed again.

    2 OPERATION MODE SELECTION BUTTON
    Used to select the operation mode.

    3 ROOM TEMPERATURE SETTING BUTTONS
    Used to select the room temperature.

    4 INDOOR FAN SPEED SELECTOR
    Used to select fan speed in four steps-low,
    medium, high, or CHAOS.

    ■ Operation Mode
    Cooling Operation

    Cooling Operation
    Auto Operation

    Auto Operation
    Soft Dry Operation
    Soft Dry Operation

    Heating Operation

    (Cooling Model)

    (Heat Pump Model)

    8 Convertible Air conditioner



  • Page 9

    Operating Instructions

    - Features of the Remote Control- Door Opened

    1

    7

    3

    2
    ON

    OFF

    8
    9

    4
    5
    SET

    6

    CANCEL

    10
    11

    Flip-up door(opened)

    1 OPERATION DISPLAY
    Displays the operation conditions.

    2 START/STOP BUTTON
    Operation starts when this button is pressed and
    stops when the button is pressed again.

    3 OPERATION MODE SELECTION BUTTON
    Used to select the operation mode.

    4 ON/OFF TIMER BUTTONS
    Used to set the time of starting and stopping
    operation.

    5 TIME SETTING BUTTONS
    Used to adjust the time.

    7 AIR FLOW DIRECTION START/STOP BUTTON
    Used to stop or start louver movement and set
    the desired up/down airflow direction.

    8 SLEEP MODE AUTO BUTTON
    Used to set Sleep Mode Auto operation.

    9 AIR CIRCULATION BUTTON
    Used to circulate the room air without cooling or
    heating (turns indoor fan on/off).

    10 ROOM TEMPERATURE CHECKING BUTTON
    Used to check the room temperature.

    11 RESET BUTTON
    Used prior to resetting time or after replacing
    batteries.

    6 TIMER SET/CANCEL BUTTONS
    Used to set the timer when the desired time is
    obtained and to cancel the Timer operation.

    Owner's Manual 9

    ENGLISH

    Signal transmitter



  • Page 10

    Operating Instructions

    Cooling Operation

    1

    Press the Start/Stop button.
    The unit will respond with a beep.

    2

    To select Cooling Operation, press the Operation Mode Selection
    button.
    Each time the button is pressed, the operation mode is shifted in
    the direction of the arrow.

    Cooling

    3

    Auto

    Soft Dry

    Heating
    (Heat pump model only)

    Set the temperature lower than the room temperature. The
    temperature can be set within a range of 18°C~30°C in 1°C
    increments.

    To raise the temperature

    To lower the temperature

    4

    10 Convertible Air conditioner

    You can select the fan speed in four steps-low, medium, high, or
    CHAOS. Each time the button is pressed, the fan speed mode is
    shifted.



  • Page 11

    Operating Instructions

    Auto Operation
    Press the Start/Stop button.
    The unit will respond with a beep.

    2

    To select Auto Operation, press the Operation Mode Selection
    button.
    Each time the button is pressed, the operation mode is shifted in
    the direction of the arrow.

    Cooling

    3

    Auto

    ENGLISH

    1

    Soft Dry

    Heating
    (Heat pump model only)

    The temperature and fan speed are automatically set by the
    electronic controls based on the actual room temperature. If you
    want to change the set temperature, close the door on the remote
    control and press the Room Temperature Setting buttons. The
    cooler or warmer you feel, the more times (up to two times) you
    should press the button. The set temperature will then be changed
    automatically.

    To raise the temperature

    To lower the temperature

    During Auto Operation:
    ❏ You cannot switch the indoor fan speed. It has already been set by the Fuzzy rule.
    ❏ If the system is not operating as desired, manually switch to another mode. The system will not
    automatically switch from the cooling mode to the heating mode, or from heating to cooling, it must be
    done by manually resetting.
    ❏ During Auto Operation, pressing the chaos swing button makes the horizontal louvers swing up and down
    automatically. If you want to stop auto-swing, press the chaos swing button again.

    Owner's Manual 11



  • Page 12

    Operating Instructions

    Soft Dry Operation

    1

    Press the Start/Stop button.
    The unit will respond with a beep.

    2

    To select Soft Dry operation, press the Operation Mode Selection
    button.
    Each time the button is pressed, the operation mode is shifted in
    the direction of the arrow.

    Cooling

    3

    Auto

    Soft Dry

    Heating
    (Heat pump model only)

    Set the temperature lower than the room temperature. The
    temperature can be set within a range of 18°C~30°C in 1°C
    increments.

    To raise the temperature

    To lower the temperature

    12 Convertible Air conditioner



  • Page 13

    Operating Instructions

    Heating Operation(Heat pump model only)

    2

    Press the Start/Stop button.
    The unit will respond with a beep.

    To select Heating operation, press the Operation Mode Selection
    button.
    Each time the button is pressed, the operation mode is shifted in
    the direction of the arrow.

    Cooling

    3

    ENGLISH

    1

    Auto

    Soft Dry

    Heating
    (Heat pump model only)

    Set the temperature higher than the room temperature.
    The temperature can be set within a range of 16°C~30°C in 1°C
    increments.

    To raise the temperature

    To lower the temperature

    4

    You can select the fan speed in four steps–low, medium, high, or
    CHAOS. Each time the button is pressed, the fan speed mode is
    shifted.

    Owner's Manual 13



  • Page 14

    Additional Features

    Additional Features
    Sleep Mode
    1 Press the Sleep Mode Auto button to set the
    time you want the unit to turn off automatically.

    2 The Timer is programmed in one-hour
    increments by pressing the Sleep Mode Auto
    button 1 to 7 times.
    The sleep mode is available for 1 to 7 times. To
    alter the time period in steps of 1 hour, press the
    Sleep Mode Button while aiming at air
    conditioner.

    To cancel the Sleep Mode, press the sleep Mode
    Auto button several times until the star
    (
    ) disappears from the operation display.
    Note: The Sleep Mode will be operated at low
    fan speed (cooling) or medium fan speed (heat
    pump only) for quiet sleeping.
    IN COOLING MODE: The temperature will
    automatically rise by 1°C over the next 30 minutes
    and by 2°C in 1 hour for comfortable sleeping.

    3 Make sure the Sleep Mode Auto LED lights up.

    Setting the Timer
    Time can be set only when you have pressed the
    Reset button. If you have just replaced the batteries,
    the Reset button should be pressed to reset the time.

    2 Press the Time Setting buttons until the desired
    time is set.

    1 Press the Start/Stop button.
    3 Press the Timer SET button.

    SET

    Note: Check the indicator
    for A.M. and P.M.

    Delay Start/Pre-Set Stop
    1 Make sure the time is set correctly on the
    remote control display.
    ON

    OFF

    2 Press the ON/OFF Timer

    4 Press the selected on/off setting by

    SET

    pressing the Timer SET button while
    aiming the remote control at the signal
    receptor.

    buttons to turn Timer on or off.

    3 Press the Time Setting
    buttons until the desired
    time is set.

    To cancel the setting the timer.
    CANCEL
    Press the Timer Cancel button while aiming
    remote control at the signal receptor.
    (The timer lamp on the air conditioner and
    the display will go out.)

    NOTE: Select one of the following four types of operation.

    14 Convertible Air conditioner



  • Page 15

    Additional Features

    Vertical Airflow Direction Control
    1 The up/down airflow (Vertical Airflow) can be

    R

    To adjust left/right(Horizontal Airflow) direction

    2 Press the Start/Stop button to start the unit.

    Caution : Ensure unit is turned off before adjusting the
    horizontal airflow direction control.
    Carefully open vertical louver to allow
    access to the horizontal airflow direction.

    3 Press Chaos Swing button and the louvers will
    swing up and down. Press the Chaos Swing
    button again to set the vertical louver at the
    desired airflow direction.

    Adjust the left/right airflow direction by hand.

    R

    Air Circulation Mode
    Circulates the room air without cooling or heating.

    1 Press the Start/Stop button. the unit will respond with a beep.
    2 Press the Air Circulation button. Now each time that you press the Indoor Fan Speed Selector, the fan
    speed is shifted from low to CHAOS and back to low again.

    CHAOS Air

    Fan speed is on low.

    Fan speed is on medium.

    Fan speed is on high.

    Note:
    ❏ The fan speed of the indoor unit will automatically cycle depending on the room temperature.
    ❏ CHAOS Air economizes power consumption and prevents overcooling. The fan speed is automatically
    changed from medium to low or vice versa, depending on the ambient temperature.

    Owner's Manual 15

    ENGLISH

    adjusted by using the remote control.

    Note:
    ❏ Always use the remote control to adjust the up/down
    airflow direction. Manually moving the vertical
    airflow direction louver by hand could damage the
    air conditioner.
    ❏ When the unit is shut off, the up/down airflow
    direction louver will close the air outlet vent of the
    system.



  • Page 16

    Additional Features

    Forced Operation
    • Operation procedures when the remote control can't be
    used.
    • Press the Forced Operation button.

    R

    • If you want to stop operation, press again.
    • When started, the operation conditions are automatically
    set as follows:
    • During Forced Operation, the initial mode continues.

    Cooling Model

    Room Temp. ≥ 24°C

    Heat pump Model
    21°C ≤ Room Temp. < 24°C

    Room Temp. < 21°C
    Heating

    Operating mode

    Cooling

    Cooling

    Soft Dry

    Indoor FAN Speed

    High

    High

    Soft Dry Rule

    High

    Setting Temperature

    22°C

    22°C

    Air Intake Temperature

    24°C

    Auto Restart
    In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate
    procedures automatically to the previous operating conditions.
    In case the air conditioner does not receive any signal from the remote control, it will turn off automatically
    after 7 hours.

    When The Front Grille is Opened:
    Once the front grille is opened for cleaning of the air filters or other reasons, the unit automatically stops
    operation for safety: In some 60 Hz models (for cooling only), all memorized functions such as operation
    mode, room temperature setting, operation start & stop by timer setting, etc. shall be erased.
    To restart the unit, close the front grille and press the Start/Stop button on the remote controller. If
    necessary, please reset the reservation functions like operation start & stop and room temperature setting.

    16 Convertible Air conditioner



  • Page 17

    Additional Features

    Operation Details
    Soft Dry Operation Mode (Refer to page 14)

    In Soft Dry Operation, the indoor fan speed is automatically switched to the low.
    ROOM TEMP.
    COOLING

    ROOM TEMP.

    SET TEMP. +1°C
    SOFT DRY
    SET TEMP. -0.5°C

    INDOOR
    FAN

    SETTING
    FAN
    SPEED
    LOW COOL
    OPERATION

    COMP.

    OPERATE

    OPERATE
    FOR
    10 MINS

    STOP
    FOR 3 MINS
    OPERATING START

    LOW COOL
    OPERATION

    OPERATE
    FOR
    10 MINS
    STOP
    FOR 7 MINS
    Room Temp.

    Natural wind by the CHAOS logic (Refer to page 17)
    For more fresh feeling than other fan speed,
    press the Indoor Fan Speed Selector and set to
    CHAOS mode. In this mode, the wind blows like
    natural breeze by automatically changing fan
    speed according to the CHAOS logic.

    0.5°C
    0.5°C
    1HOUR
    11/2HOUR

    CHAOS MODE OPERATION

    Helpful information
    Fan speed and cooling capacity.
    The cooling capacity indicated in the specification is the value when
    the fan speed is set to high, and the capacity will be lower at low or
    medium fan speed.
    High fan speed is recommended when you wish to cool the room
    quickly.

    h
    Hig ed
    e
    Sp

    Owner's Manual 17

    ENGLISH

    When the room temperature is higher than the set temperature, it operates in cooling mode at the set
    temperature, the set fan speed (if CHAOS mode, then medium.), and then it will be in automatically switched to
    Soft Dry Mode when the room temperature reaches the set temperature.



  • Page 18

    Maintenance and Service

    Maintenance and Service
    CAUTION: Before performing any maintenance, turn off the main power to the system.

    Indoor Unit
    Grille, Case, and Remote
    Control
    ❏ Turn the system off before cleaning. To clean,
    wipe with a soft, dry cloth. Do not use bleach or
    abrasives.
    Note: Supply power must be disconnected before
    cleaning the indoor unit.

    ❏ Never use any of the followings:
    • Water hotter than 40°C
    Could cause deformation and/or discoloration.
    • Volatile substances
    Could damage the surfaces of the air
    conditioner.

    SI

    Be

    N NER

    n zene

    SCO
    U RIN G
    C LB
    A R GER

    Vertical louver
    Horizontal louver
    Air outlet vent Air inlet vent Air filters

    1 Lift the front access panel and pull the filter tab

    Air Filters
    The air filters behind the front grille should be
    checked and cleaned once every 2 weeks or more
    often if neccessary.

    slightly forward to remove the filter.

    2 Clean the filter with a vacuum or warm, soapy
    water.
    • If dirt is conspicuous, wash with a solution of
    detergent in lukewarm water.
    • If hot water (50°C or more) is used, it may be
    deformed.

    3 After washing with water, dry well in the shade.
    4 Re-install the air filter.

    Outdoor Unit
    The heat exchanger coils and panel vents of the
    outdoor unit should be checked regularly. If clogged
    with dirt or soot, the heat exchanger and panel vents
    may be professionally steam cleaned.
    Note: Dirty or clogged coils will reduce the operating
    efficiency of the system and cause higher
    operating costs.

    18 Convertible Air conditioner

    (Side)

    (Rear)

    Air intake
    vents

    Piping

    Air outlet
    vents

    Drain
    Hose



  • Page 19

    Maintenance and Service

    Troubleshooting
    Check the following points before requesting repairs or service.... If the fault persists, please contact your dealer or service center.

    Explanation

    See page
    16

    The air conditioner does not
    operate.

    • Check room temperature setting?
    • Check if circuit breaker is on?

    The room has a peculiar
    odor.

    • Check that this is not a damp smell exuded by
    the walls, carpet, furniture, or cloth items in the
    room.

    -

    It seems that condensation
    is leaking from the air
    conditioner.

    • Check the drain hose is connected tight or if
    indoor unit is installed even.

    -

    Air conditioner does not
    operate for about 3 minutes
    after turning on.

    • This is the protector of the mechanism.
    • Wait about 3 minutes and operation will begin.
    • About 3 minutes delay is applied to protect
    compressor from frequenty on/off.

    Does not cool or heat
    effectively.

    • Is the air filter dirty? See air filter cleaning
    instructions.

    18

    • Has the temperature been set correctly?

    10~13

    -

    -

    • Are the indoor unit's air inlet or outlet vents
    obstructed?

    -

    • For a noise that sounds like water flowing.
    -This is the sound of refrigerant flowing inside
    the air conditioner unit.
    • For a noise that sounds like the compressed
    air releasing into atmosphere.
    -This is the sound of the dehumidifying water
    being processed inside the air conditioning
    unit.

    -

    Remote Controller display is
    faint, or no display at all.

    • Are the batteries depleted?
    • Are the batteries inserted in the opposite (+)
    and (-) directions?

    7

    Crack sound is heard.

    • This sound is generated by the
    expansion/constriction of the front panel, etc.
    due to changes of temperature.

    -

    The air conditioner
    operation is noisy.

    Owner's Manual 19

    ENGLISH

    Case



  • Page 20

    Memo

    20 Convertible Air conditioner



  • Page 21

    P/No.: MFL62047501
    Printed in Korea
    After reading this manual, keep it in a place easily accessible to the user for future reference.






Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für LG V24LH wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Holen Sie sich Ihr Benutzerhandbuch per E-Mail

Geben Sie Ihre E-Mail-Adresse ein, um das Handbuch zu erhalten von LG V24LH in der Sprache / Sprachen: Englisch als Anhang in Ihrer E-Mail.

Das Handbuch ist 1,07 mb groß.

 

Sie erhalten das Handbuch in Ihrer E-Mail innerhalb von Minuten. Wenn Sie keine E-Mail erhalten haben, haben Sie wahrscheinlich die falsche E-Mail-Adresse eingegeben oder Ihre Mailbox ist zu voll. Darüber hinaus kann es sein, dass Ihr ISP eine maximale Größe für E-Mails empfangen kann.

Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info