SPECIFICATIONS
X-15
Depth Ranges:
Feet, fathoms,
meters.
Operating Frequency:
192 kHz
(192,000
cycles per
second); accuracy
is within 0.6
percent.
Pulse
Length:
(duration
of
pulse):
200-1000/ks
(30-2000/ks
programable)
Operating Voltage:
Minimum: 10 volts DC
Maximum: 15 volts
DC
Operating
Current:
0.7 to 1.8
amps
depending
on
printing density
and
output
power.
Output
Power:
1600 watts
typical peak-to-peak.
(200
watts
RMS)
Weight:
8.5 lb.
(3.9 Kg)
Dimension:
With Gimbal Mount:
Width
-
12¼"
Height
-
8%"
Depth
-
5¼"
Instrument
Only:
Width
-
91/2"
Height
-
7½"
Depth
-
5¼"
NOTICE
Periodically
wash the Trans-
ducer
Face with
soap
and water
to
remove
any
oil film that
may
collect Oil and dirt on the
face
will reduce
sensitivity
or
may
even
prevent sounding.
GOT A PROBLEM? LET US
HELP!
If
you
have a
problem
with
your
sonar
unit,
please
give
us a
chance to
help
before
sending
it in
for
repair.
Assistance can often
be ex-
tended
by
telephone
or letter.
Write or call one
of our Authorized
Service Centers or the Lowrance
Electronics, Inc.,
Customer
Ser-
vice
Department
in
Tulsa,
OK.
(Toll-free
1-800-331-3889).
Please detail
the
problem you
are
experiencing.
Our Service
De-
partment may
be able
to save
you
the inconvenience of
returning
your
unit.
If it is determined
that
your
unit
must be
returned,
full
shipping
in-
structions will be
provided.
SCHEMATIC DIAGRAM AND
PARTS LIST
Should
you
desire a Schematic
Diagram
and Parts list for
your
Lowrance TRUELINE RECORD-
ER,
send
$1.00
to PARTS
LIST,
Lowrance
Electronics, Inc.,
12000
East
Skelly
Drive, Tulsa,
Okla-
homa 74128. Be sure and
give
us
the Model Number and Serial
Number of
your
SONAR
INSTRUMENT.
Figure
2
The
stylus
continues to move
down
the
edge
of the
paper
while
the sound
pulse
is
traveling
through
the
water,
and when an
echo is
detected,
the
stylus
makes
another
mark on the
paper.
The
depth
of the
object
which reflected
the echo can
be read in feet
by
comparing
its location on the
paper
to the
depth
scale
printed
on the
paper.
A variable
speed
motor drives
the
paper graph. (The paper
is
treated
so that the
stylus
will burn
it to leave a
permanent
black
mark.) During
one revolution of
the
stylus
belt,
a
very
narrow mark
will be made
by
the flexible
stylus,
but
the
paper
will move a small
amount before
the next revolution.
Each
mark will blend into the one
before,
so
that a
composite pic-
ture" of
the
target
will be
made,
one
tiny
mark at a time.
Due to the
many
features that
-
this unit
has,
we
have
split
the
operation
section of
this manual
into two sections. The first section,
- Section
Ill,
is entitled Basic
Op-
eration" and covers
everything
that
is
absolutely
necessary
to use the
X-15
is a wide
variety
of
situa-
tions. It will tell
you
how to use the
basic controls
Sensitivity, Sup-
pressor,
Paper Speed,
Grayline,
Range, plus
a few
special
functions.
This section will
be
adequate
for
most situations. However,
once
you
have mastered
the basic
op-
eration of the
X-15 as described
in Section
III, you may
wish to
try
some of the features
described in
Section
VI
Advanced
Opera-
tion. This
chapter
will
explain
four
other features that
will enable the
serious
operator
to
get
the
maximum use out
of this
equipment.
We
urge you
to
read this man-
ual
thoroughly
and familiarize
yourself
with the controls.
Al-
though
this is a
very
advanced
unit,
it is
easy
to
use,
thanks to
the
power
of the
microcomputer
and the front
panel
controls.
Should
you require
extra
help,
please phone
our Customer
Ser-
vice
Department
toll
free at
1-800-331-3889.
(Oklahoma
resi-
dents call collect
-
1-918-437-
6881).
A service
representative
will
be
happy
to
help you.
II INSTALLATION
Mounting
The
depth
sounder
may
be in-
stalled in
any
convenient area,
provided
the unit
can be tilted for
the best
viewing
angle.
Four holes
in the bracket base
allow wood
screw or bolt
mounting.
A wood
stiffener
may
be
required
on the
3
22
GRAPH
PAPER
PDF compression, OCR, web-optimization with CVISION's PdfCompressor
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Lowrance X-15 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info