Note
If no setting command is received within 60 seconds the module
will automatically exit programming mode.
Cancelling programming mode
Briefly press the program button
once; the red LED is now off,
or wait 60 seconds so
that programming mode
is cancelled automatically.
!
Figure 1. To activate and cancel programming mode, insert a screwdriver through the
opening (A) in the rear of the box.
A
20
Programming (continued)
Programming the options
The table below shows the standard settings and options.
The SAX35 is set to "Standard".
Proceed as follows to access the options:
Put the module into programming mode.
Send the desired command in "Setup Command" twice,
via a program and measurement interface (PMIX35) or a
Marmitek X-10 Control Box.
The program LED confirms the "Setup Command" by flashing a
specific number of times.
Cancel programming mode.
Must always be programmed
Standard Optional Setup Number
Command flashing
Send address A1 A1 … P16 Desired address 1
Receive address A3 A1 … P16 Desired address 2
Note: If the receive address is programmed lower than the send
address, one free address should be left between the two
addresses. The programmed send address and programmed
receive address must therefore always differ by at least
2 addresses. Example: if the send address is C7, the receive
address cannot be programmed as C6, C7 or C8.
21
Optional settings for the output:
Standard Optional Setup Number
Command flashing
No All Lights On All Lights On All Lights On 6
No All Lights Off All Lights Off All Lights Off 10
No All Units Off All Units Off All Units Off 8
Note
When in programming mode, always enter the address first
and then the other settings.
When a new address is programmed the optional commands
are lost (reset).
!
22
Programming (continued)
Example where the send address is programmed on D3 and the
receive address on D6
Event Result
Input 1 is connected to supply SAX35 sends D3 Don
Input 1 is disconnected SAX35 sends D3 Doff
Input 2 is connected to supply SAX35 sends D4 Don
Input 2 is disconnected SAX35 sends D4 Doff
SAX35 receives D6 Don Relay contact closes
SAX35 receives D6 Doff Relay contact opens
23
Input 1
Input 1
Input 2
Input 2
Uitgang 2
Relais
output
3k2
3k2
R1
R5
X4
D2
D1
X2
+
+
SAX15
Figure 2. Internal diagram of galvanically separated section.
24
Connection example
Figure 3 shows an application in which an input on the SAX35 is
activated by a bell transformer switch. In this way, pressure on
the doorbell button is converted into a Marmitek X-10
command. When doorbell switch S1 is closed, the SAX35 sends
the programmed send address plus an ON command. When S1
is opened, the SAX35 sends the programmed send address plus
an OFF command.
Lamp L1 is switched by the relay output. When the SAX35
receives the programmed receive address plus an ON
command, L1 will switch on. When the SAX35 receives the
programmed receive address plus an OFF command, L1 will
switch off.
230 V~
+
Input 1
L1
Transformer
Relais
output
Figure 3.
Connection
applications
example.
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Marmitek SAX35 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info