786817
1
Zoom out
Zoom in
Vorherige Seite
1/2
Nächste Seite
Installation
Installation Installatie
Installation IVET
ENGLISH: Connect the AC load to the AC output (OUTPUT). For safe installation it is necessary to:
Connect both the earth (PE/GND) and the neutral (N) of the AC output of the IVET to the central grounding point
which is connected to the hull of the ship.
Integrate a Residual Current Device (RCD) in wiring of the AC output
Refer to local applicable regulations on these issues
Connect the incoming shore power to the AC input (INPUT). Phase line to L and Neutral to N.
Do NOT connect the ground wire (PE/GND) of the shore power to the central grounding point (hull of the ship), neither
to the PE/GND connection of the output!
NEDERLANDS: Sluit de belasting aan op de AC uitgang (OUTPUT). Voor een veilige installatie dient u:
zowel de aarde (PE/GND) als de nul (N) van de uitgang van de IVET door te verbinden met het centraal aardpunt,
welke in verbinding moet staan met de romp van het schip.
in het uitgangscircuit van de IVET een 30mA aardlekschakelaar op te nemen.
Raadpleeg hiertoe de plaatselijk geldende richtlijnen.
Sluit de bedrading naar de walstroom aan op de AC ingang (INPUT), fase op L en nul op N.
De aardedraad (PE/GND) van de walstroom mag niet aangesloten worden op het centraal aardpunt (romp van het
schip) of de PE/GND aansluiting van de AC-uitgang!
DEUTSCH: Schließen Sie die AC-Last an den AC-Ausgang (OUTPUT) an. Für eine sichere Installation ist es
erforderlich:
sowohl die Erde (PE/GND) und den Nullleiter (N) des AC-Ausgangs des IVET an den zentralen Erdungspunkt
anzuschließen, der mit dem Rumpf des Schiffes verbunden ist.
ein Reststromgerät (RCD) in der Verkabelung des AC-Ausgangs zu installieren.
Nehmen Sie hinsichtlich dieser Punkte Bezug auf die örtlich anwendbaren Vorschriften.
Schließen Sie den eingehenden Landstrom an den AC-Eingang (INPUT) an, die Phasenleitung an L und den Nullleiter
an N.
Schließen Sie den Erdungsdraht (PE/GND) des Landstroms NICHT an den zentralen Erdungspunkt (Schiffsrumpf) an
und ebenfalls nicht an den PE/GND-Anschluss des Ausgangs!
FRANÇAIS : Raccorder la charge CA à la sortie CA (OUTPUT). Pour sécuriser l'installation, vous devez :
Raccorder à la fois la terre (Mise à la terre) et le neutre (N) de la sortie CA de l’IVET au point de masse central
connecté à la coque du bateau.
Intégrer un dispositif de courant résiduel (DCR) dans le câblage de la sortie CA.
Se référer à ce sujet aux réglementations locales en vigueur
Connecter l'alimentation quai entrante à l'entrée CA (INPUT). La ligne de phase au L et le Neutre au N.
Ne PAS connecter le fil de terre (Mise à la terre) de l'alimentation quai au point de masse central (coque du bateau), ni
à la connexion Mise à la terre de la sortie !
Only allow changes in your electrical system to be carried out by qualified electricians!
Laat veranderingen aan uw elektrische installatie alleen door gekwalificeerde elektriciens uitvoeren!
Sie sollten Änderungen Ihres Elektrosystems nur von qualifizierten Elektrikern durchführen lassen!
Seuls des électriciens qualifiés peuvent apporter des modifications à votre système électrique !
SPECIFICATIONS
IVET w/o Cabinet (IP00) 2.5 kVA up to 22 kVA
IVET in Dakar cabinet (IP23) 2.5 kVA up to 4.5 kVA
IVET in Steel plate cabinet (IP23) 6.0 kVA up to 22 kVA
Produced according to: VDE 0550, VDE 0532
Isolation class: T 40/E
Transformer type: E-core
Input voltage: 110 – 220 – 240 Volt
Output voltage: 110 – 220 – 240 Volt
Phase: 1
Input frequency: 50 / 60Hz
Output frequency: Same as input frequency
Cooling: Natural convection
Automatic voltage selector No (optional)
Soft start included No (optional)
Circuit breaker included No Dimensions of the E-core transformer IVET without cabinet
Mastervolt International B.V, P.O.Box 22947, NL-1100 DK Amsterdam, The Netherlands. Tel.: +31-20-3422100 Email: info@mastervolt.com Web: www.mastervolt.com v2.0 060901
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Mastervolt IVET 3.5 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info