Please read these instructions thoroughly, before using the pump!
This appliance is not suitable for use by persons (including children) with limited physical, sensory or mental
capabilities or lacking experience and/or knowledge, except if they are supervised by a person responsible
for their safety or have been instructed in the use of the appliance.
Children should be supervised in order to make sure that they do not play with the appliance.
Use
Centrifugal pump for submersible usage with resin encapsulated motor.
The pumps are designed for use in water, for instance: swimming pond, swimming pool, garden pond, fi sh
pond, fountain, terrace fountain, indoor fountain, for operating fi lters systems, watercourses etc. as well as
for aerating and recirculating water.
Please refer to the type plate for technical specifi cations or the table on page 1.
Safety measures
- Caution! It may only be used in garden ponds and in their protection area, if the electrical installations
have been set up to comply with the code‘s requirements. The following standards must be complied
with when setting up these pumps in swimming ponds/swimming pools: DIN EN 13451 Part 1 to Part 8,
as well as DIN VDE 0100 Part 702 and part 737. Please contact an electrician.
- Before use: Check whether mains connection and plug are intact.
- Mains voltage and type of current have to correspond to the data on the type plate.
- The pump has to be connected to a regular safety plug socket through a residual current
device (RCD, 30 mA).
- Supply of the pump with 12 V safety extra-low voltage (SELV) must be executed via a safety
transformer in accordance with VDE 0570.
- Attach connection outlet and safety transformer in an area that is protected from water and
that is at least 2 m from the edge of the pond (see Fig. 1).
- Keep the plug dry!
- Important! When the mains connection or the motor housing are damaged, the pump cannot be used
anymore. It cannot be repaired since the connection is cast into the motor housing.
- Do never hang up or transport the pump by the cable!
- The pump must be run submerged!
Start-up (see fi g.1)
Important! Do not let the pump run dry. This could cause damages to the appliance.
- Immerse the pump completely in your pond. This causes the pump body to be fi lled with water.
- A minimum water depth of 15 cm is required for underwater operation to avoid the pump taking in air.
- The maximum depth for submerged operation of the
2 m
pump is 2 m!
- The water temperature should not exceed 35°C.
- Do not let the pump freeze in the wintertime.
- The pump is switched on by putting the plug in the socket.
- To prevent the pump becoming unnecessarily dirty, place it above the mud in your pond, in a fi rm and
horizontal position (on a brick)!
- A range of accessories may be fi tted onto the threaded connection of the pump.
- Running in conjunction with fountain jets, the pump should be positioned fi rmly and horizontally
(on a brick).
- To prevent the fountain jets becoming clogged, we recommend you to fi t the enclosed fi lter
sponge.
Dismantling / Assembly (see fi g. 2 - 5)
1. Follow the safety measures. Disconnect the pump!
2. Press together the fi lter cover (1) laterally and take it out of the pump (8).
3. Pull the fi lter sponge (2) out of the fi lter cover (1).
4. Turn the inlet lid (3) counterclockwise and take it out of the pump (8).
5. Pull the rotor (4) out of the pump (8).
6. The complete rotor (4) can be made to rotate on the axle.
7. The impeller and the magnet, too, may be turned against each other through a predetermined angle.
8. Clean all components - please use clear water only - so that they allow to be easily moved. Do not
use sharp-edged objects.
9. Proceed as follows in order to reassemble the pump
9.1. Replace complete rotor (4) in the pump (8).
9.2. Insert the inlet lid (3) in the pump (8), holding it in the same position as when you took it out of it,
then turn it clockwise until it stops.
9.3. Insert the fi lter sponge (2) in the fi lter cover (1).
9.4. Insert the front (1) and rear (6) fi lter covers in the pump (8).
To ensure proper functioning, repeat the above procedure frequently, depending on clogging and
working time.
Maintenance
In order to prolong the service life of your pump and to keep it in good operating condition, it is
recommended to carry out maintenance and cleanup regularly. This can be done by everyone, quickly and
easily. See „Dismantling/Assembly“
Servicing intervals
- In the beginning check performance of your pump every day. If necessary, clean the fi lters.
- Since servicing intervals (complete cleanup) will vary depending on pond pollution, repeat the periodic
service to your pump in accordance with the requirements given.
Should you determine that there are damaged or worn parts, do replace them. See „Spare parts“.
Winter / Pump care
Protect your pump from freezing-in!
Take the pump out of your pond in autumn.
Clean the pump completely following the outlined instructions.
During the winter months store the pump in a frost-resistant room.
Spare parts
For ordering spare parts, please indicate the pump type, the de signation and the Art.-No. as per table
below. (see also fi g. 5)
Item Designation Pump Type Art-No.
1 Filter cover front M 800 - 12 V, M 1200 - 12 V, M 1600 - 12 V 168/009063
2 Filter sponge M 800 - 12 V, M 1200 - 12 V, M 1600 - 12 V 168/009064
3 Lid incl. sealing ring M 800 - 12 V, M 1200 - 12 V, M 1600 - 12 V 168/009073
4 Rotor complete M 800 - 12 V 168/009067
M 1200 - 12 V 168/009068
M 1600 - 12 V 168/009069
6 Filter cover back M 800 - 12 V, M 1200 - 12 V, M 1600 - 12 V 168/009066
7 Handle/Stand M 800 - 12 V, M 1200 - 12 V, M 1600 - 12 V 168/009072
Guarantee conditions
This pump comes with a 36-month guarantee that is effective from the date of delivery. The invoice will be
the proof of the date. In case of damages due to defects in material or manufacturing, we shall either do a
free repair during the guarantee period or replace the damaged part, the choice being ours’.
Damages that occur due to installation and operating errors, lime deposits, insuffi cient care, frost action,
normal wear and tear or improper repair attempts will not come under this guarantee. The guarantee will
not be valid in case of modifi cations to the pump, e.g. cutting off the line connection or the line cord. We
will not accept responsibility for consequential damages resulting from breakdown of the pump or improper
operation.
When making use of the guarantee, please send us the pump, along with the corresponding invoice, free of
charge via the specialist dealer who sold you the pump.
Waste disposal
Waste disposal of electronic devices by the user in private households of the EU
It is not allowed to dispose the product along with the regular waste disposal, instead it has to be collected
separately. It is your responsibility to dispose and recycle the device in a proper place and protect the
environment through this. More information, where to dispose your devices can be obtained at the local
departments.
GB
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Messner System M 1600 - 12 V wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info