- With 18 and 36 watt UVC lamps the 1“-1 1/4“ joint (30) can be
mounted at connection B, swiveled into any desired position, and fixed
with the 28x3 O-ring (35), the 1 1/4“ hose fitting (31), and the 1 1/4“
gasket (34).
- With the 9 and 11 watt lamps, the elbow hose connector with screw
cap and O-ring (23) can be mounted at connections A and B and
rotated 360°.
Cleaning and changing the lamp (see fig. C)
Dismantling
1. Follow the safety measures.
2. Disconnect the UV-C unit and secure against reclosing.
3. Pour out the water completely
.
4. Rotate the screw cap (7) at the end cap (6) in counterclockwise
direction to release.
5. Remove the end cap (6) CAREFULLY: the UVC lamp (1) is attached
to it. Pay attention to the O-ring (5) at the end cap (6)!
6. Hold the UVC lamp (1) at the base and remove and replace if
necessary. Old UVC lamps should not be broken and disposed of
in household waste. Please consult with your waste removal
contractor.
7. Rotate the pressure piece (10) in counterclockwise direction to
release, and remove.
8. Carefully extract silica tube (2) from the housing (11). Pay attention
to the O-ring (3/4) on the silica tube (2).
9. Carefully clean all parts. Do not use tools with sharp edges.
Replace the silica tube or the o-ring if defective.
Replacing the starter (only for 18+36 watts)
10. Release the 2 screws (12) in the end cap (6) and extract the lamp
holder (13) together with the socket (14).
11. Remove the starter (16) and rotate in counterclockwise direction to
release and extract from the starter socket (15).
12. Insert the new starter (16) in the starter socket (15) and rotate in
clockwise direction to secure.
13. Insert starter (16) and starter socket (15) into the end cap (6), insert
lamp holder (13) with lamp socket (14), and secure with the 2
screws (12).
Assembly
14. Slide the O-ring (3/4) onto the silica tube (2) and insert both parts
into the housing.
15. Rotate the pressure piece (10) in clockwise direction to secure the
silica tube (2).
16. Position the O-ring (5) properly on the end cap (6).
17. Rotate the screw cap (7) in counterclockwise direction on the
housing (11) to secure the end cap (6) with the UVC lamp (1).
Taking care of your UV-C unit in winter
Protect your UV-C unit from freezing-in!
Empty, dismount and clean the unit thoroughly in autumn.
Store it in a non-freezing room during the winter months.
Please read these instructions thoroughly, before using the
UV-C unit!
Use
This UV-C unit is suitable for use in garden or fish ponds helping to
clear polluted pond water.
It is not allowed to use the unit in or on the side of swimming pools!
For all technical data please refer to the type plates.
Safety measures
- Caution! UV-C radiation is dangerous to eyes and skin!
Do operate the UV-C unit only inside the casing. An integrated
safety switch protects against UVC radiation when the device is
open; the UVC lamp is lighted only when the UVC unit is
completely assembled! The correct function can easily and safely
be checked by the inspection glass (8) shining violet.
- It may only be used in garden ponds and in their protection area, if the
installations have been set up to comply with the code’s requirements.
Please contact an electrician.
- The UV-C unit has to be connected to a regular safety plug socket
through a circuit breaker (ground fault circuit interruptor, 30 mA).
- Before use: Check whether mains connection and electrical box are
intact.
- The mains connection of the electrical box cannot be replaced. If the
connection is damaged the device has to be scrapped.
- If the mains connection between electrical box and UV-C unit is dama-
ged it must be replaced by the manufacturer or his customer service or
similarly qualified personnel in order to avoid dangers.
- Mains voltage and type of current have to correspond to the data on
the type plate of the electrical box.
- The connection box and the electrical box (for indoor use only)
should be located in a water-protected area. They should be at
least 2 m away from the edge of the pond (see fig. A + B).
- Keep the plug dry!
- Pull out mains plug before starting to work on the UV-C unit,
garden or fish pond. (Disconnect the electrical box.)
- It is not allowed to run the UV-C unit when people are inside the
water!
- Do never immerse the UV-C unit in water and make sure that the unit
may not be flooded.
- Do never hang up or transport the UV-C unit by the cables.
- Avoid exposure to intense sunlight.
Start-up (see fig. A, B + C)
Important! Make sure that water always passes through the UV-C
unit during operation. Otherwise the unit could be damaged.
- You should only connect a pump with a max. delivery head of 10 m
(1 bar).
- The water temperature should not exceed 35° C.
- Fasten the UV-C unit by means of the fixing stands (9) in a flood-proof
position.
- The quartz glass tube (2) will be polluted by the pond water, thus
reducing the UV-C performance. This needs cleaning of the quartz
glass tube (2) at regular intervals according to the degree of pollution.
- The UV-C lamp (1) has a rated life of approx. 8000 hours. After that it
should be replaced, at least at the end of one season (from March till
October).
- We recommend you to run the unit 24 hours a day (continuous use).
Avoid frequent switching (on/off). This will reduce the lifetime of the
UV-C lamp.
- A 1” thread can be connected to the inlet or outlet of these UVC lamps.
- With the included hose fittings hoses to the pump and to the filter can
be mounted directly.
10 11
GB
130-003196_02/07_UV-C PL 9/11/18/36 Watt_BA 21.02.2007 11:23 Uhr Seite 13
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Messner UV-C PL 36 Watt wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info