16.2 READING OUT THE DATA ON A BID CHIP
If you wish to read out the saved data, you must first press the
"STOP / ESC" button. This display now shows the maximum
charged-in and discharged capacity of all the charge / discharge
processes involving this battery.
Note:
The data cannot be displayed if any process (charging, dischar-
ging, etc.) is currently active.
The illustration shows a typical screen display, which gives you a
means of estimating the values for your battery, and accurately
assessing the overall state of the pack . No additional equipment,
such as a PC with the appropriate software, is required.
An analysis of the example display shows the following:
•Todatethebatteryhasbeenchargedtwicewiththecharger,
terminating with the "END" message.
•Thehighestcharged-incapacitywas1100mAh.Atthe
moment a capacity of 1000 mAh has been charged in.
•Thehighestdischargedcapacitywas600mAh.Atthemoment
a capacity of 500 mAh has been discharged.
BID Info
LiPo11.1V4000mAh
Last ChgCapa : 1000 mAh
Max ChgCapa : 1100 mAh
Num ChgCycles: 2
Last dChgCaps: 500 mAh
Max dChgCaps: 600 mAh
19. ERROR MESSAGES
The Power Peak
®
D7 EQ-BID is equipped with special safety fea-
tures to ensure safe and reliable charging and discharging operati-
ons. As soon as a fault occurs, a corresponding message appears
on the screen, and the piezo buzzer emits a warning tone. After
eliminating the cause, you can erase the following error messages
by pressing the "STOP / ESC" button.
[ Error ]
DC input too low
* Please check the
Input voltage!
[ Error ]
Interruption
* The battery
is disconnected.
* Please connect the battery
and start.
[ Error ]
Reverse polarity
* The battery is connected to
the output with reversed
polarity!
[ Error ]
Balance lead error
* Connect the
balance lead.
[ Error ]
DC input too high
* Please check the
Input voltage!
[ Error ]
Capacity limit
* The set capacity
limit has been reached.
[ Error ]
Cell count incorrect
* Incorrect number of cells set
[ Error ]
No battery
* No battery is
connected to the output.
[ Error ]
Cell error
*Voltageofonebatterycellis
too low.
[ Error ]
Connection error
* The battery was disconnected
during an active process.
* Possible short-circuit
at the output.
18. USB PC SOCKET
The Power Peak
®
D7 EQ-BID is fitted with two mini-USB sockets
at the front. A USB lead can be connected to either of these sok-
kets for connection to a PC. The appropriate lead can be obtained
from any electronics shop. Software updates can be loaded using
this lead.
USB charge socket
Thechargerisfittedwitha5V/1AUSBchargesocketonthe
front. This can be used for charging smart-phones and digital
cameras.
16.1 STARTING CHARGE / DISCHARGE PROCESSES WITH
BID CHIP / KEY
When you have edited and saved the BID data, the "BID EDIT"
screen display appears. Processes are initiated from this display.
This is accomplished by holding the "START / ENT." button
pressed in for at least two seconds. The various modes (CHARGE,
DISCHARGE, STORAGE, FAST-CHARGE, BALANCE, etc.) are
then displayed.
The procedure is identical to that required for starting a process for
one of the twenty memories ("Memory name" menu). The same
set-up facilities and parameters are available.
After highlighting the desired process using the "+" or "-" but-
tons, hold the "START / ENT." button pressed in for at least two
seconds to start.
saved to the BID chip or key: navigate to the "Store" line, and press
the "START / ENT." button to save the data.
If the BID chip or key has already been operated with another char-
ger, the data are naturally adopted. However, if the set parameters
are not compatible with the D7 charger (charge / discharge current,
cell count, capacity or "Special" battery with the Power Peak E1), an
error message appears, and you have to re-enter the data.
17. CHARGE OUTPUT 2 / OUT2
The Power Peak
®
D7 EQ-BID charger is fitted with a second charge
output, which has the same specification as Output 1. Both charge
outputs can be operated independently of each other.
Note:
Do not wire the outputs together in parallel or in series!
29

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Multiplex Power Peak D7 EQ-BID - 30 8129 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info