Notes:
• The recorder will stop if you leave it idle for 3 minutes during a menu setup operation, when a
selected item is not applied.
• If you press the
STOP (4) button during a menu setup operation, the recorder will stop and
apply the items that were set to that point.
Other Functions
VCVA indicator
h Recording Modes [HQ SP LP]
The recording mode can be chosen from [HQ] (high quality sound record-
ing), [SP] (standard recording) and [LP] (long-term recording).
In Menu mode selection...
[HQ], [SP], [LP]
HQ SP LP
VN-6500
VN-6000
Approx. 40 h.
30 min.
Approx. 107 h.
55 min.
Approx. 604 h.
15 min.
VN-5500
VN-5000
Approx. 20 h.
5 min.
Approx. 53 h.
40 min.
Approx. 300 h.
30 min.
Current recording mode
Alarm indicator
h Moving File between Folders
You can move files recorded in folders [%], [&], ['] and [(] to other folders. The moved file is
added to the end of the destination folder.
Current microphone
sensitivity
2 Press the + or button to
select what you would like
to set up.
The selected menu item flashes.
3 Press the or 0 but-
ton to change the setting.
4 Press the
PLAY
(`) button
to confirm the setting.
5 Press the
STOP
(4 ) button to close the
menu.
h Alarm Playback Function [
I
]:
You can use the alarm playback function to sound the alarm tone for
5 minutes at the scheduled time. Within this 5 minutes, pressing any
button other than the HOLD switch starts the recorder to playback the
preselected file.
In Menu mode selection...[
SET
], [
On
], [
OFF
]
After selecting [
SET
], press the
PLAY
( `) button to set the
time.
Note:
With the alarm playback function, only one le can be played back. Select
a le for the function before setting the time.
1 Select the file you want to transfer, and press
the
PLAY
(`) button to play it.
Notes:
• The destination folder and the number of the moved le appear on the display, and moving is
completed.
If the destination folder is full (100 les), [
FULL] appears on the display, and you cannot move the
le to that folder.
2 While the recorder is during playback mode,
press and hold the
DISP
/
MENU
button for 1
second or longer.
3 Press the 9 or 0 but-
ton to select a destination
folder.
4 Press the
PLAY
(`) but-
ton.
a Destination folder
b Destination number of the file
h Microphone Sensitivity [
F
]
h Using the Variable Control Voice
Actuator [VCVA]
h System Sounds [BEEP]
Informs a button operation or a wrong operation of the recorder by sound.
System sounds may be turned off.
In Menu mode selection...[On], [OFF]
Note:
If the alarm playback function has been set, the alarm will sound at the
scheduled time even if the system sounds are disabled.
h Timer Recording [TIMER]:
You can schedule for automatic recording, specifying the start time and
end time of recording. When the timer-controlled recording completes,
the setting is released.
In Menu mode selection...[
SET
], [
On
], [
OFF
]
After selecting [
SET
], press the
PLAY
(`) button to set the
time.
To cancel the timer setting:
For the timer in the menu mode, select [
OFF
], and press the
PLAY
(`) button.
When the microphone senses that sound has reached a preset volume,
the built-in Variable Control Voice Actuator (VCVA) starts recording
automatically, and stops it when the volume drops. Particularly helpful for
extended recording, the VCVA not only conserves memory by turning off
recording during silent periods, but also makes playback more efficient
and convenient.
In Menu mode selection...[On], [OFF]
Notes:
During recording, press the
+ and buttons to adjust the VCVA level in
15 levels.
The Record/Play indicator light is lit during recording. When the recorder
is in Standby mode, the Record/Play indicator light ashes and [VCVA]
ashes on the display.
Notes:
To view the current setting, select [
On], and press the PLAY (`) button.
With this function, you can set only the start and the end time of recording. The current settings of
the recording mode, microphone sensitivity, VCVA and folder are applied for the settings before
you set timer-controlled recording.
The setting exceeding the remaining recording time is not allowed.
You can record at any time even if it is not within the specied recording duration. However, if that
makes the remaining recording time insucient for the timer-controlled recording, the recording
will not complete.
If any operation is ongoing, the timer-controlled recording is overridden.
To cancel an alarm playback:
For [I] in the menu mode, select [
OFF
] and press the
PLAY (
`
)
button.
Notes:
Regardless of the selected folder, once the alarm playback is set, it operates every day unless the
setting is canceled.
To view the current setting, select [
On], and press the PLAY ( `) button.
The alarm tone stops automatically if no button is pressed within 5 minutes after the alarm starts.
The le is not played back in this case.
If the recorder has no recorded le in the selected folder, the alarm playback function is not
available.
Alarm playback occurs every day unless it is set to [
OFF].
b
a
Timer indicator
Microphone sensitivity is adjustable to meet your recording needs.
In Menu mode selection...[
E
], [
G
]
EG
High-sensitivity mode that records
sounds in all directions.
Low-sensitivity mode suited for
dictation.
Notes:
To ensure successful recording, make a test recording to select
appropriate microphone sensitivity before recording.
If you select [
E], we recommend setting the recording mode to [HQ]
to best take advantage of the higher sensitivity.
If you select [
E], background noise may be high depending on the
recording conditions.
Notes:
The recording time shown above is for one continuous le. The available recording time may be
shorter than specied if several les are recorded. (Use the remaining time and recorded time
only as references.)
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Olympus VN-6000 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Olympus VN-6000

Olympus VN-6000 Bedienungsanleitung - Französisch - 2 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info