Zoom out
Zoom in
Vorherige Seite
1/10
Nächste Seite
Jumbo Weather Station
Model: BAR283
User Manual
P/N: 086L004374-016_EN REV1
1/10
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Inhalt der Seiten


  • Page 1

    Jumbo Weather Station
    Model: BAR283
    User Manual

    P/N: 086L004374-016_EN REV1
    1/10



  • Page 2

    EN

    Jumbo Weather Station
    Model: BAR283

    INTRODUCTION
    Thank you for selecting the Oregon ScientificTM Jumbo
    Weather Station (BAR283). This powerful device
    bundles time keeping, weather forecast, indoor and
    outdoor temperature, with remote control facility, into a
    single tool you can use from the convenience of your
    home.

    USER MANUAL

    CONTENTS
    Introduction............................................................... 1

    In this box, you will find:

    Product Overview ..................................................... 2
    Front View .............................................................. 2

    • Main unit (BAR283)

    Back View .............................................................. 2

    • Remote sensor (RTHR328N)

    LCD Display .................................................... 2

    • Main unit batteries, 4 x UM-3 (AA) 1.5V

    Remote Sensor (RTHR328N) - Front View ............ 3

    • Remote sensor batteries, 2 x UM-3 (AA) 1.5V

    Remote Sensor (RTHR328N) - Back View ............ 3
    Remote Sensor (RTHR328N) - LCD Display ......... 3

    NOTE The THGR328N (5-Channel) and THR228N (3Channel) remote sensors are also compatible with this
    weather station. If you purchase the THGR328N sensor,
    the humidity reading will not show on the BAR283.
    Additional sensors are sold separately. Please contact
    your local stockist for more information.

    Getting Started.......................................................... 3
    Batteries ................................................................. 3
    Remote Sensor (RTHR328N) ................................... 3
    Sensor Set Up ........................................................ 3
    Sensor Data Transmission ..................................... 4

    Keep this manual handy as you use your new product.
    It contains practical step-by-step instructions, as well
    as technical specifications and warnings you should
    know.

    Select Sensor Channel .......................................... 4
    Search for Sensor .................................................. 4
    Clock and Calendar .................................................. 4
    Radio-Controlled Clock .......................................... 4
    Turn Radio-Controlled Clock ON / OFF ................. 5
    Set Clock ................................................................ 5
    Switch Clock Display .............................................. 5
    Hourly Chime ......................................................... 5
    Alarm ......................................................................... 6
    View Alarm Settings ............................................... 6
    Set Alarm ................................................................ 6
    Activate Alarm ........................................................ 6
    Silence Alarm ......................................................... 6
    Weather Forecast ..................................................... 6
    Weather Forecast Icons ......................................... 6
    Temperature .............................................................. 6
    Maximum / Minimum Records ................................ 6
    Select Measurement Unit ....................................... 6
    Backlight ................................................................... 6
    Reset System ............................................................ 6
    Safety and Care ........................................................ 7
    Warnings ................................................................... 7
    Troubleshooting ....................................................... 7
    Specifications ........................................................... 7
    About Oregon Scientific .......................................... 8
    EU-Declaration of Conformity ................................ 8

    1
    BAR283_EN.indd 1

    P/N: 086L004374-016_EN REV1
    2/10

    3/17/06 6:33:33 PM



  • Page 3

    EN

    PRODUCT OVERVIEW

    2. Indoor Temperature Area: Maximum, minimum,
    and current readings

    FRONT VIEW

    3. Weather Forecast Area: Animated weather
    forecast
    4. Outdoor Temperature Area: Maximum, minimum,
    and current readings; sensor channel number
    Clock / Alarm / Calendar Area
    1

    2

    7

    1. CHANNEL: Switch remote sensor display

    8

    3

    2. MEMORY: View current, maximum and minimum
    temperature readings

    9

    4
    5
    6

    3. MODE / LIGHT: Change settings / display; activate

    1. Time Zone Hour Offset

    backlight

    2. Time / date / calendar

    4. LCD display

    3. Channel number 1-5

    5. ALARM: View alarm status; set alarm

    4. RF clock reception

    6. UP / DOWN: Increase / decrease setting; activate /

    5. Backlight function is deactivated

    deactivate radio-controlled clock

    (under low battery condition)
    6. Alarm setting display

    BACK VIEW

    7. Alarm is activated
    8. Low battery icon for main unit
    9. Hourly chime icon
    Indoor Temperature Area

    1

    1

    4
    5

    2

    3

    2
    6

    3

    1. Indoor temperature - °C / °F
    1. Wall mount

    2. Indoor icon

    2. Table stand

    3. MAX / MIN temperature

    3. Battery compartment: Uses 4 x UM-3 (AA) 1.5V
    4. RESET hole

    Outdoor Temperature Area

    5. °C / °F button
    6. Ventilation holes

    3

    1
    4

    LCD DISPLAY

    2

    1. Outdoor temperature - °C / °F
    1

    3

    2. Channel number (1-5) / reception status
    3. Low battery icon for remote sensor
    4. MAX / MIN temperature

    2

    4

    1. Clock / Alarm / Calendar Area: Radio-controlled
    clock; alarm; calendar
    2
    BAR283_EN.indd 2

    P/N: 086L004374-016_EN REV1
    3/10

    3/17/06 6:33:36 PM



  • Page 4

    EN

    3. Low battery indicator

    REMOTE SENSOR (RTHR328N) - FRONT VIEW

    4. Time
    5. Temperature - °C or °F
    6. Temperature reading

    1

    GETTING STARTED
    BATTERIES

    2

    Batteries are supplied with this product:
    • Main unit

    4 x UM-3 (AA) 1.5V

    • Remote sensor

    2 x UM-3 (AA) 1.5V

    3

    Insert batteries before first use, matching the polarity
    as shown in the battery compartment. For best results,
    install batteries in the remote sensor before the main
    unit. Press RESET after each battery change.

    1. LCD display
    2. LED status indicator

    To install the main unit batteries:

    3. Ventilation duct

    REMOTE SENSOR (RTHR328N) - BACK VIEW

    1

    2
    3
    4
    5
    6

    NOTE Do not use rechargeable batteries.

    7

    shows when batteries are low.
    UNIT

    8

    LOCATION

    Main

    Clock/Alarm/Calendar Area

    Remote Sensor

    Outdoor Temperature Area

    NOTE It is recommended that you use alkaline batteries
    with this product for longer performance.

    1. Wall mount
    2. CHANNEL switch (1-5)
    3. RESET

    REMOTE SENSOR (RTHR328N)

    4. °C / °F

    This product is shipped with the RTHR328N Remote
    Sensor. The main unit can collect data from up to 5
    sensors.

    5. SEARCH
    6. EU / UK radio signal format switch
    7. Battery compartment

    The THGR328N and THR228N sensors are also
    compatible with this weather station. (Additional sensors
    are sold separately. Contact your local stockist for more
    information.)

    8. Fold-out stand

    REMOTE SENSOR (RTHR328N) - LCD DISPLAY

    The RTHR328N sensor collects temperature readings
    and signals from official time-keeping organizations for
    the radio-controlled clock.

    SENSOR SET UP
    1. Open the battery compartment with a small Phillips
    screwdriver and insert the batteries matching the
    polarity (+ and -) as shown below.

    1. Reception
    2. Channel number (1-5)

    BAR283_EN.indd 3

    P/N: 086L004374-016_EN REV1
    4/10

    3
    3/17/06 6:33:40 PM



  • Page 5

    EN

    SENSOR DATA TRANSMISSION
    Data is sent from the sensor(s) every 60 Seconds. The
    reception icon shown in the Outdoor Temperature Area
    indicates the status.
    ICON

    DESCRIPTION
    Main unit is searching for
    sensors.

    2. Set the channel by pressing the CHANNEL button
    to the required number. If you are using more than
    one sensor, select a different channel for each
    sensor.

    At least 1 channel has been
    found.
    Sensor 1 is sending data.
    (The number shows which
    sensor is selected.)

    3. Slide the EU / UK switch to the setting which best
    suits your location.

    --- shows in Temp
    Area

    4. Press RESET.
    5. Place the sensor near the main unit.
    6. Press SEARCH to manually initiate signal sending
    between the sensor and the main unit. The
    reception icon on the main unit will blink for
    approximately 3 minutes while it is searching for
    the sensor. (Refer to the “Sensor Data
    Transmission” section for more information.)

    The selected sensor cannot
    be found. Search for the
    sensor or check batteries.

    SELECT SENSOR CHANNEL
    Press CHANNEL on the main unit, to switch between
    sensors 1-5.

    7. Press the °C / °F button to select the setting you
    want.

    The house icon shows the selected remote sensor.

    8. Close the remote sensor battery compartment.
    9. Secure the sensor in the desired location using the
    wall mount or table stand.

    To auto-scan between sensors, press and hold
    CHANNEL for 2 seconds. Each sensor’s data will be
    displayed for 3 seconds.

    To fold out the stand:
    To end auto-scan, press CHANNEL or MEMORY.
    1

    SEARCH FOR SENSOR
    To search for a Thermo sensor, simultaneously press and
    hold CHANNEL and MEMORY for 2 seconds.

    2

    NOTE If the sensor is still not found, check the
    batteries.
    For best results:
    • Insert the batteries and select the unit, channel,
    and radio signal format before you mount the
    sensor.

    CLOCK AND CALENDAR
    This product tracks the time and date based on radiocontrolled signals from the RTHR328N remote sensor,
    or manual settings that you enter.

    • Place the sensor out of direct sunlight and moisture.
    • Do not place the sensor more than 30 metres (100
    feet) from the main (indoor) unit.

    RADIO-CONTROLLED CLOCK

    • Position the sensor so that it faces the main
    (indoor) unit, minimizing obstructions such as
    doors, walls, and furniture.

    The time and date are automatically updated by radio
    controlled clock signals from official time-keeping
    organizations in Frankfurt (Germany) and Rugby
    (England) unless you disable this feature. The signals
    are collected by the remote sensor (RTHR328N)
    whenever it is within 1500 km (932 miles) of a signal.

    • Place the sensor in a location with a clear view to
    the sky, away from metallic or electronic objects.
    • Position the sensor close to the main unit during
    cold winter months as below-freezing
    temperatures may affect battery performance
    and signal transmission.

    Initial reception takes 2-10 minutes, and is initiated when
    you first set up the unit, and whenever you press RESET.
    Once complete, the reception icon will stop blinking.

    NOTE The transmission range may vary and is subject
    to the receiving range of the main unit.

    The reception icon
    indicates 2 factors:

    You may need to experiment with various locations to
    get the best results.

    shown in the Clock Area

    4
    BAR283_EN.indd 4

    P/N: 086L004374-016_EN REV1
    5/10

    3/17/06 6:33:43 PM



  • Page 6

    • RF signal reception (

    You can select 1 of the 5 following languages:
    SYMBOL

    )

    LANGUAGE
    English

    How these signals work together:
    ICON

    EN

    • Connection between the main unit and the sensor
    that collects RF signals ( )

    German

    MEANING
    The unit has contact with
    the remote sensor and has
    synchronized the time.

    French
    Italian

    The unit has contact with the
    remote sensor but the time has
    not been synchronized

    Spanish

    The unit has lost contact with
    the remote sensor but the time
    is synchronized

    SWITCH CLOCK DISPLAY

    The unit has lost contact with
    the remote sensor but the time
    is not synchronized

    • RF time with hour-offset time (HH:MM)

    Press MODE / LIGHT to toggle between the following
    clock displays:

    The unit cannot reach the
    remote sensor.

    NOTE To force a manual search for the RF clock
    reception, press and hold SEARCH on the sensor
    (RTHR328N).

    • Day of the week

    TURN RADIO-CONTROLLED CLOCK ON / OFF
    If you wish to manually set the clock, you must first
    disable the radio-controlled feature. To do this, make
    sure you are not in Setting Mode, then press and hold
    DOWN on the main unit for 2 seconds. To enable it, hold
    UP for 2 seconds.
    • When the RF clock is enabled this icon
    appear on the display.

    will

    • When the RF clock is disabled this icon
    NOT appear on the display.

    will

    • Calendar

    • RF time without offset

    SET CLOCK
    You only need to do this if you have disabled the radiocontrolled clock, or if you are too far from a RF signal.
    1. Press and hold MODE / LIGHT for 2 seconds to
    enter Setting Mode.
    • Time-zone hour-offset setting

    Each display will be backlit for 5 seconds and will return
    to the main screen display after 10 seconds.

    2. The setting will blink to indicate it can now be
    changed.
    3. Press UP or DOWN to change the setting.
    4. Press MODE / LIGHT to confirm the setting and
    move to the next one. The order of the settings is:
    time zone hour offset (+ / -23 hours), 12 / 24 hour
    format, hour, minute, year, date / month format,
    month, date, display language and hourly chime
    (ON / OFF).

    HOURLY CHIME
    The hourly chime function when set to ON will beep once
    at the beginning of every hour, and the chime icon will
    show on the display.

    5
    BAR283_EN.indd 5

    P/N: 086L004374-016_EN REV1
    6/10

    3/17/06 6:33:48 PM



  • Page 7

    EN

    ALARM

    WEATHER FORECAST ICONS

    This product is equipped with a 2-minute crescendo
    alarm.

    ICON

    DESCRIPTION
    Clear

    /

    VIEW ALARM SETTINGS

    Day / Night

    Press ALARM. The alarm time and status will show in
    the Clock Area.

    /

    Partly cloudy

    Day / Night

    SET ALARM

    Cloudy

    1. Press ALARM to switch to alarm display.
    Rainy
    Snowy

    NOTE The night time icon displays from 6 PM to 6
    AM.

    2. Press and hold ALARM again, for 2 seconds. The
    alarm settings will blink.

    TEMPERATURE

    3. Select the hour and minute. Press UP or DOWN to
    change settings. Press ALARM to confirm. The
    alarm will be activated automatically.

    This product can display maximum, minimum and
    current temperatures collected by the remote sensors
    and main (indoor) unit.

    ACTIVATE ALARM
    MAXIMUM / MINIMUM RECORDS

    Press ALARM. twice to start toggling between alarm
    ON and alarm OFF.

    • Press MEMORY to toggle between maximum
    (MAX),

    shows in the Clock / Alarm Area when the alarm is
    activated.

    minimum (MIN) and current records.
    • To clear the records, press and hold MEMORY for

    NOTE Press MODE, or wait 1 minute to return to clock
    display.

    2 seconds. A beep will sound to confirm that the
    memory has been cleared.

    SILENCE ALARM

    SELECT MEASUREMENT UNIT

    When the alarm time is reached, the crescendo alarm
    will sound for 2 minutes and the backlight will turn on
    for 5 seconds. To silence the alarm:

    Press the °C / °F button to choose the setting you want.
    The display can show indoor temperatures ranging from
    -5°C to +50°C (23°F to +122°F).

    • Press any key on the main unit to mute the alarm
    and activate it again after 24 hours.

    BACKLIGHT
    To turn on the backlight for 5 seconds:

    If no button is pressed, the alarm will automatically
    silence after 2 minutes.

    • Press MODE / LIGHT on the main unit.
    NOTE When
    appears, the backlight function is
    deactivated due to low-battery power. Replace with new
    batteries to operate this function again.

    WEATHER FORECAST
    This product forecasts the next 12 to 24 hours of weather
    within a 30-50 km (19-31 mile) radius. The forecast is
    based on barometric pressure trend readings.

    RESET SYSTEM
    Insert a thin blunt instrument into the hole below RESET
    to return to the default settings.
    NOTE When you press RESET, all settings will return to
    default value, and you will lose all stored information.

    The LCD display shows an animated icon indicating the
    forecasted weather.
    6
    BAR283_EN.indd 6

    P/N: 086L004374-016_EN REV1
    7/10

    3/17/06 6:33:51 PM



  • Page 8

    SPECIFICATIONS

    Clean the product with a slightly damp cloth and alcoholfree, mild detergent. Avoid dropping the product or
    placing it in a high-traffic location.

    Main Unit Dimensions

    EN

    SAFETY AND CARE

    LxWxH

    225 x 24 x 141 mm
    (8.86 x 0.94 x 5.55 inches)

    Weight

    542 grams (1.19 lbs)
    without battery

    WARNINGS

    Remote Sensor Dimensions

    This product is designed to give you years of service
    if handled properly. Oregon Scientific will not be
    responsible for any deviations in the usage of the
    device from those specified in the user instructions or
    any unapproved alterations or repairs of the product.
    Observe the following guidelines:
    • Never immerse the product in water. This can
    cause electrical shock and damage the product.

    LxWxH

    70 x 24.5 x 116 mm
    (2.76 x 0.96 x 4.57 inches)

    Weight

    108 grams (0.24 lbs)
    without battery

    Temperature

    • Do not subject the main unit to extreme force,
    shock, or fluctuations in temperature or humidity.
    • Do not tamper with the internal components.
    • Do not mix new and old batteries or batteries of
    different types.
    • Do not use rechargeable batteries with this product.
    • Remove the batteries if storing this product for a
    long period of time.

    Unit

    °C or °F

    Indoor Range

    -5°C to 50°C
    (23°F to 122°F)

    Outdoor Range

    -20°C to 60°C
    (-4°F to 140°F)

    Resolution

    0.1°C (0.2°F)

    Memory

    Min / Max

    • Do not scratch the LCD display.
    • Placement of this product on wood surfaces with
    certain types of finishes, such as clear varnish, may
    result in damage to the finish. Consult the furniture
    manufacturer’s care instructions for direction as to
    the types of objects that may safely be placed on
    the wood surface. Oregon Scientific shall not be
    responsible for any damage to wood surfaces from
    contact with this product.

    Weather Forecast

    RF frequency

    433 MHz

    • Do not dispose this product as unsorted municipal
    waste. Collection of such waste separately for
    special treatment is necessary.

    Range

    Up to 30 metres (100 feet) with
    no obstructions

    Transmission

    Approx. every 1 minute

    Channel No.

    1, 2, 3, 4 or 5

    Unit

    °C or °F

    Display

    Sunny (day / night), partly cloudy
    (day / night), cloudy, rainy,
    snowy

    Remote Unit (RTHR328N)

    NOTE The technical specification of this product and
    contents of this user manual are subject to change
    without notice. Images not drawn to scale.

    Radio-Controlled Clock

    TROUBLESHOOTING
    PROBLEM

    SYMPTOM

    REMEDY

    Calendar

    Strange date /
    month

    Change language

    Clock

    Cannot adjust
    clock

    Disable radiocontrolled clock

    Cannot autosynch

    1. Adjust batteries

    Synchronization

    Auto or disabled

    Clock display

    HH:MM

    Hour format

    12hr AM / PM
    (MSF format)
    24hr (DCF format)

    Calendar

    2. Press RESET

    languages (E, G, F, I, S)

    3. Manually
    activate radiocontrolled clock
    Temp

    Shows “LLL” or
    “HHH”

    Temperature is
    out-of-range

    Remote
    sensor

    Cannot locate
    remote sensor

    Check batteries

    DD / MM or MM / DD;
    Day of the week in 1 of 5

    Alarm

    Daily with 2-minute crescendo

    Power
    Main unit
    Batteries

    4 x UM-3 (AA) 1.5V

    Remote Sensor
    Batteries

    2 x UM-3 (AA) 1.5V

    WARNINGSZ
    7
    BAR283_EN.indd 7

    P/N: 086L004374-016_EN REV1
    8/10

    3/17/06 6:33:52 PM



  • Page 9

    EN

    NOTE It is recommended that you use alkaline batteries
    with this product for longer performance.

    ABOUT OREGON SCIENTIFIC
    Visit our website (www.oregonscientific.com) to learn
    more about Oregon Scientific products such as digital
    cameras; MP3 players; children’s electronic learning
    products and games; projection clocks; health and
    fitness gear; weather stations; and digital and conference
    phones. The website also includes contact information
    for our Customer Care department in case you need
    to reach us, as well as frequently asked questions and
    customer downloads.
    We hope you will find all the information you need on our
    website, however if you’re in the US and would like to
    contact the Oregon Scientific Customer Care department
    directly, please visit:
    www2.oregonscientific.com/service/default.asp
    OR
    Call 1-800-853-8883.
    For international inquiries, please visit:
    www2.oregonscientific.com/about/international.asp
    EU-DECLARATION OF CONFORMITY
    Hereby, Oregon Scientific, declares that this Jumbo
    Weather Station (BAR283) is in compliance with the
    essential requirements and other relevant provisions
    of Directive 1999/5/EC. A copy of the signed and dated
    Declaration of Conformity is available on request via our
    Oregon Scientific Customer Service.

    COUNTRIES RTTE APPROVED
    All EU countries, Switzerland

    CH

    and Norway

    N

    8
    BAR283_EN.indd 8

    P/N: 086L004374-016_EN REV1
    9/10

    3/17/06 6:33:53 PM



  • Page 10

    © 2006 Oregon Scientific. All Rights Reserved.
    086L004374-016

    P/N: 086L004374-016_EN REV1
    10/10






Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Oregon Scientific BAR283 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Holen Sie sich Ihr Benutzerhandbuch per E-Mail

Geben Sie Ihre E-Mail-Adresse ein, um das Handbuch zu erhalten von Oregon Scientific BAR283 in der Sprache / Sprachen: Englisch als Anhang in Ihrer E-Mail.

Das Handbuch ist 2,37 mb groß.

 

Sie erhalten das Handbuch in Ihrer E-Mail innerhalb von Minuten. Wenn Sie keine E-Mail erhalten haben, haben Sie wahrscheinlich die falsche E-Mail-Adresse eingegeben oder Ihre Mailbox ist zu voll. Darüber hinaus kann es sein, dass Ihr ISP eine maximale Größe für E-Mails empfangen kann.

Andere Handbücher von Oregon Scientific BAR283

Oregon Scientific BAR283 Bedienungsanleitung - Deutsch - 8 seiten

Oregon Scientific BAR283 Bedienungsanleitung - Holländisch - 8 seiten

Oregon Scientific BAR283 Bedienungsanleitung - Französisch - 8 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info