Wireless Weather Station with
Temperature / Humidity Display and
Self - Setting Atomic Clock
MODEL: BAR688HGA
INTRODUCTION
Thank you for selecting this Oregon Scientic
TM
Wireless
Weather Station with Temperature / Humidity Display and
Self - Setting Atomic Clock (BAR688HGA). This clock
is supplied with a remote sensor (THGR122N) and can
support up to 3 sensors in total (additional sensors sold
separately).
NOTE Please keep this manual handy as you use your new
product. It contains practical step-by-step instructions, as
well as technical specications and warnings you should
know about.
CLOCK OVERVIEW
FRONT VIEW
1. SNOOZE
2. Weather Forecast Area
3. Outdoor Temperature Area
4. Indoor Temperature Area
5. Clock / Alarm Area
BACK VIEW
1. TEMP / HUMIDITY HI / LO : Change settings or
enable / disable hi or lo temperature / humidity alarm
for channel 1
2. / : Increase / decrease setting; activate / deactivate
clock reception signal
LCD DISPLAY
Weather Forecast Area:
Outdoor Temperature Area:
1. Heat index icon
2. Hi / lo temperature alarm
3. Sensor reception icon
4. Sensor battery low
5. Max / min icon
6. Temperature display
7. Ice warning is active
8. Hi / lo humidity alarm
9. Temperature trend
10. Humidity trend
11. Humidity display

Indoor Temperature Area:
1. Internal sensor icon
2. Max / min icon
3. Temperature display
4. Temperature trend
5. Humidity trend
6. Humidity display
Clock / Alarm Area:
1. Alarm set
2. AM / PM icon
3. Clock signal reception
4. Low battery icon
5. Clock
6. Alarm mode icon
7. Moon phase
REMOTE SENSOR (THGR122N)
1. LED status indicator:
Blinks red during data
transmission
2. LCD screen
1. Wall mount hole
2. RESET hole
3. CHANNEL switch
4. Battery compartment
GETTING STARTED
SETTING UP THE CLOCK
Insert batteries before rst use, matching the polarity (+
and -). RESET after each battery change.
SENSOR DATA TRANSMISSION
indicates main unit batteries are low.
NOTE Do not use rechargeable batteries. We
recommend that you use alkaline batteries with this product
for longer usage and lithium batteries in temperatures
below freezing.
REMOTE SENSOR
The sensor collects temperature readings approx. every
40 seconds and sends them to the main unit. The main
unit can collect data from up to 3 sensors.
To set up the sensor:
1. Remove the screws from the battery door.
2. Insert the batteries, matching the polarity (+ / -).
3. Select a channel. Make sure you use a different channel
for each sensor.
4. Place the sensor near the main unit. Press RESET on
the sensor.
5. Simultaneously press CHANNEL and MEM on the main
unit to initiate signal sending between the sensor and
main unit.
6. Close the battery door and secure the screws
7. Place the sensor in the desired location using the table
stand or wall mount.
For best results:
Place the sensor out of direct sunlight and moisture.
Do not place the sensor more than 30 m (100 ft) from
the main (indoor) unit.
Position the sensor so that it faces the main (indoor)
unit, minimizing obstructions such as doors, walls, and
furniture.
Place the sensor in a location with a clear view to the
sky, away from metallic or electronic objects.
Position the sensor close to the main unit during cold
winter months as below-freezing temperatures may
affect battery performance and signal transmission.
Data is sent from the sensor(s) every 40 seconds. The
sensor reception icon in the remote sensor area shows
the status.
ICON DESCRIPTION
and “- - . -“
(Outdoor
temperature area)
The sensor cannot be found.
Search for the sensor or check
batteries
To search for a sensor:
Simultaneously, press and hold MEM and CHANNEL for
2 seconds.
NOTE If the sensor is still not found, check the batteries,
obstructions, and remote unit location.
CLOCK
CLOCK RECEPTION
This product is designed to synchronize its date and time
automatically once it is within range of the WWVB-60 signal
from the atomic clock in Boulder, Colorado.
The sensor collects the radio signals whenever it is within
1500 km (932 miles) of a signal.
NOTE Initial reception takes 2-10 minutes for rst set up
or when RESET is pressed. Once complete, the reception
icon will stop blinking. If the signal is weak, it can take up
to 24 hours to get a valid signal.
RECEPTION SIGNAL
To enable and force a signal search:
Press and hold for 2 seconds.
To disable the signal reception:
Press and hold for 2 seconds.
ashes when it is disabled.
STRONG SIGNAL WEAK SIGNAL NO SIGNAL
SET CLOCK
To manually set the clock make sure the clock signal
reception is disabled.
1. Press and hold MODE for 2 seconds.
2. Select the US time zone (Pacic (P), Eastern (E),
Central (C) and Mountain (M)), hour, minute, year,
month, day and language. Press or to change the
setting.
3. Press MODE to conrm.
NOTE The language options are English (E), German (D),
French (F), Italian (I), and Spanish (S).
Press MODE to choose between the clock with seconds
and clock with weekday display modes.
1. Pressure trend
2. Weather forecast
3. Comfort zone
4. Pressure icon
5. Altitude icon
6. Pressure / Altitude unit
7. UV index icon
USER MANUAL
3. CHANNEL: Switch remote sensor display
4. HEAT INDEX: Display heat index
5. MODE: Change settings / display
6. ALARM: View alarm status; set alarm
7. Battery compartment
8. MEM: View current, maximum and minimum
temperature / humidity
9. PRESSURE: Select pressure unit; set altitude
10. °C / °F: Select temperature unit
11. RESET: Reset unit to default settings
The transmission range may vary depending on many
factors. You may need to experiment with various locations
to get the best results.
Standard Alkaline batteries contain signicant amounts of
water. Because of this they will freeze in low temperatures
of approximately -12°C (10°F). Disposable Lithium
batteries have a much lower threshold for temperature
with an estimated freezing range of below -30°C (-22°F).
Wireless ranges can be impacted by a variety of factors
such as extremely cold temperatures. Extreme cold may
temporarily reduce the effective range between the sensor
and the base station. If the unit's performance fails due to
low temperature, the unit will resume proper functioning
as the temperature rises to within the normal temperature
range (i.e. no permanent damage will occur to the unit due
to low temperatures).
Sensor 1 is sending data
A channel has been found
Main unit is searching
for the sensor(s)
Clock signal reception indicator:
BAR688HGA_M 2005.12.12, 4:06 PM1
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Oregon Scientific BAR688HGA wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info