WIND CHILL (Wind chill)
WIND (Wind speed)
BARO (Barometer)
RAINFALL (Rain)
To select time range display mode:
Press bar chart area to toggle the chart records between the following
time ranges.
LAST 24 HRS (Past 24 hours)
LAST 24 DAYS (Past 24 days)
LAST 24 MTHS (Past 24 months)
To select record range display mode:
Press
bar chart area, and then press to toggle the chart records
between the following ranges.
MAX (Maximum record)
MIN (Minimum record)
NOTE
The purpose of the bar chart is to provide a quick comparison between
the records. Changing the measurement unit will have corresponding effect on
the bar chart display.
MEMORY
MAX / MIN OF TODAY / MONTHLY RECORDS
Area Type of Memory Indicators
Temperature
Current indoor /
outdoor temperature
MONTHLY
MAX
MIN
TODAY
MAX
MIN
Heat index
MONTHLY
MAX
TODAY
Wind chill
MONTHLY
MIN
TODAY
Dewpoint
MONTHLY
MAX
TODAY
MIN
Humidity
Current indoor /
outdoor humidity
MONTHLY
MAX
MIN
TODAY
MAX
MIN
Wind Gust wind speed
MONTHLY
MAX
TODAY
Barometer Barometer
MONTHLY
MAX
MIN
TODAY
MAX
MIN
Rain
Rain rate
MONTHLY
MAX
TODAY
Rainfall
MONTHLY
MAX
TODAY
To view memory records:
1. Press desired area to activate.
2. Press
to toggle between MIN/MAX of TODAY/MONTHLY
recorded readings.
To clear individual area records:
1. Select a record in memory.
2. Press and hold for 2 seconds.
3. Delete process is complete when display changes to current reading.
NOTE
When MAX/MIN reading displays, the corresponding timestamp will be
displayed in the area
HOURLY RECORDS
Display Hourly readings of up to
Barometer 24 hours back
Hourly Rainfall 24 hours back
To view hourly records:
1. Press desired area to activate until the hour frame displays.
2. Press or to view current (0 hr) / hourly reading
(from -1hr to -24hr).
DATA LOG
The weather data can be automatically saved by setting data logger, and then you
can view the data through a PC program by uploading to the PC.
To set data log:
1. Press
area, then press to activate DATA LOG mode.
2. Press and hold
.
3. Press
or to select frequency of data recording (1 / 5 / 15
/ 60 minutes).
4. Press
.
5. Number of days memory will allow for records will be displayed.
Frequency In Minutes
No. of Days Available for Data Logging with
Memory Available
1 22D (3 weeks)
5 113D (3.5 months)
15 341D (10.5 months)
60 1364D (3.5 years)
To view remaining days for records:
Press area.
NOTE
When DATA LOG is almost full, DATA LOG flashes to remind you to
transfer the data to PC for storage. Otherwise, data logger cannot log any more
data when it is full.
To upload records to PC:
Plug the small end of the USB cable to USB port on the main unit and the big end
of the cable into the USB port of the PC. The records will be uploaded onto the
software run by the PC via the USB cable.
displays in area on main unit.
NOTE
PC program provided must be installed before uploading of records from
main unit.
To clear records:
1. Press
area, then press , DATA LOG displays.
2. Press and hold
.
3. After all the data cleared, the display shows the new time remaining. Delete
process is complete and successful.
ALARM
Weather alarms are used to alert you of certain weather conditions. Once activated,
the alarm will turn on and start flashing when a certain criterion is met. The alarm
does not flash and goes back to normal until the reading is not beyond the alarm
setting anymore.
Area Type of Alarm
Clock Daily alarm
Temperature
Current indoor / outdoor temperature
HI
LO
Heat index HI
Dew point
HI
LO
Wind chill LO
Humidity Current indoor / outdoor humidity
HI
LO
Wind Gust wind speed HI
Barometer Barometric pressure *
Rain
Rain rate HI
Past 24-hour rainfall HI
*Barometric pressure alarm is a pressure drop alarm
To set the alarm:
1. Press desired area to activate.
2. Toggle
to display current reading and HI / LO alarm.
3. Press and hold
.
4. Press
or to set the desired values.
5. Press
to confirm and continue to next setting
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Oregon Scientific WMR300 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Oregon Scientific WMR300

Oregon Scientific WMR300 Bedienungsanleitung - Deutsch, Englisch, Holländisch, Französisch, Italienisch, Portugiesisch, Spanisch, Schwedisch - 131 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info