109307
11
Zoom out
Zoom in
Vorherige Seite
1/11
Nächste Seite
- 12 -
(Fig.5).
Filter Version
To transform the exhausting version to a filter version
cooker hood, active carbon filters are required and you
should ask for them from your local supplier.
The active carbon filters purify the air that is recycled
within the environment. The filters are not washable or
regenerative and must be replaced at least every 4
months. The saturation of the active carbon depends on
the frequent use of the cooker-hood, from the type of
food cooked and the frequency of cleaning the grease.
The rectangular filters must be affixed to the exhausting
area inside the cooker-hood. Fit the pivots (K) in the
appropriate slots (Fig 4) then, using the appropriate han-
dles, and with a turning movement towards the top slot in
the pivots (J) which are located next to the handle. To do
this operation remove the grill G (Fig 2). The air is put
back into the atmosphere via the connection tube pass-
ing through the cabinet to the linking ring B (Fig 6).
USE AND MAINTENANCE
It is recommended to operate the appliance prior to
cooking.
It is recommended to leave the appliance in operation for
15 minutes after cooking is terminated in order to
completely eliminate cooking vapours and odours.
The proper function of the cooker hood is conditioned by
the regularity of the maintenance operations, in particular,
the active carbon filter.
The anti-grease filters capture the grease particles
suspended in the air, and are therefore subject to clogging
according to the frequency of the use of the appliance.
In order to prevent fire hazard, it is recommendable to
clean the filter at a maximum of 2 months by carrying out
the following instructions:
- Remove the filters from the cooker hood and wash them
in a solution of water and neutral liquid detergent, leaving
to soak.
- Rinse thoroughly with warm water and leave to dry.
- The filters may also be washed in the dishwasher.
The aluminium panels may alter in colour after several
washes. This is not cause for customer complaint nor
replacement of panels.
The active carbon filters purify the air that is replaced
in the environment. The filters are not washable nor re-
useable and must be replaced at maximum every four
months. The saturation of the active carbon filter depends
on the frequency of use of the appliance, by the type of
cooking and the regularity of cleaning the anti-grease
filters.
Clean the fan and other surfaces of the cooker hood
regularly using a cloth moistened with denatured alcohol
or non abrasive liquid detergent.
• The illumination installation is designed for use during
cooking and not for prolonged general illumination of the
environment. Prolonged use of the illumination installation
notably reduces the duration of the bulb.
• CONTROLS: ELECTRONIC (fig.7)
A = LIGHT
B = OFF/SPEED I
C = SPEED II
D = SPEED III
E = AUTOMATIC STOP TIMER – 15 minutes
F = FILTER SATURATION RESET LIGHT
When the “filter saturation” light flashes, the anti-grease
filters must be washed.
When the light comes on without flashing, the anti-grease
filters must be washed and the carbon filters replaced (in
case of operation whit the recycling version).
When this operation has been completed, press the key
to reset it.
The “automatic stop timer” delays stopping of the hood,
which will continue functioning for 15 minutes at the
operating speed set at the time this function is acti-
vated.
•COMANDS: (Fig.8) SLIDER the key symbols are ex-
plained below:
A = Light switch
A1 = Off key
A2 = On key
B = Gemma warning light key
C = Speed control
C1 = Off key
C2 = FIRST SPEED key
C3 = SECOND SPEED key
C4 = THIRD SPEED key
THE MANUFACTURER DECLINES ALL RESPONSIBILITY
FOR EVENTUAL DAMAGES CAUSED BY BREACHING
THE ABOVE WARNINGS.
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Pelgrim ISW 870 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info