Troubleshooting
About Error Messages
Message Cause Solution
Charging impossible You tried to charge the battery outside the
charging temperature range of 0 °C to 45 °C. You
cannot charge the battery outside the charging
temperature range of 0 °C to 45 °C for safety
reasons. The device may not have charged even
though the outside temperature is below 45 °C.
This happens because the device heats up when
the battery is charging.
Charge the battery in the charging temperature
range of 0 °C to 45 °C. If you turn off the device
when the battery is charging, the temperature does
not rise (
«
page 6).
The device stops charging when although it is not
charged enough even after a certain specied
charging time has passed.
This may happen because you charge the battery
while using Wi-Fi on the device with power on,
which causes to decrease the charging current.
Turn off the device’s Wi-Fi (
«
page 44).
Failed to start USB mass storage.
Disconnect, wait 5 minutes, reconnect
USB connection failed. This message also appears
when the mass storage connection is not available
and the USB is connected such as during the
setting backup.
Unplug the USB cable from the device, wait for a
while, and then try connecting again.
Storage space is getting low.
Please remove unnecessary data.
There is not enough free memory in the device
system area.
Transfer the ride log data to a PC. Delete the data
in the built-in ash memory from the PC (
«
page
26).
Please remove unnecessary data. There is not enough free memory in the built-in
ash memory of the device. This message appears
when the update data is stored temporarily to the
built-in ash memory during the update procedure.
Transfer the ride log data to a PC. Delete the data
in the built-in ash memory from the PC (
«
page
26).
Battery level is low. Please connect
power supply.
Updating will start after fully charged.
The device can be updated only when it is fully
charged to prevent update failures.
Charge the battery of the device. When charged
fully, the device starts updating automatically.
Shutdown If the remaining battery is low, this message is
displayed before shutdown.
Not while charging : Charge the battery
While charging : Continue charging the battery
Battery Level Decreasing If the remaining battery is low, this message is
displayed 5 minutes before shutdown.
Not while charging : Charge the battery
While charging : Turn off the power and continue
charging the battery.
Detected data is inconsistent. Do you
want to try again?
There is a failure in touch panel calibration data.
For example you didn't touch the plus mark during
the touch panel calibration.
Tap the center of the plus mark during the touch
panel calibration.
Built-in ash memory error There is a failure in le system of built-in ash
memory when you execute the initialization,
backup, or restore.
Format the built-in ash memory.
File Error CODE:0001 There is a le access error when you execute the
initialization, backup, or restore.
If errors occur during the initialization, try to write
the rmware again. If you still cannot solve the
problem, contact your dealer.
If errors occur during the backup, transfer the
ride log data and backup data to a PC, and then
remove them from the built-in ash memory.
Remove the unnecessary les in the built-in
ash memory.
If errors occur during the restore, copy other
backup data from the PC to the device to restore
the data.
The system try to mount the le system when you
execute the initialization, backup, or restore. If the
system can't conrm the mount, this message is
displayed.
Format the built-in ash memory.
Retry to write the rmware.
If you cannot solve the problem, contact your
dealer.
When the initialization, backup, or restore times
out, this message is displayed.
Format the built-in ash memory.
Retry to write the rmware.
If you still cannot solve the problem, contact your
dealer.
The built-in ash memory format failed. When the built-in ash memory format failed, this
message is displayed.
If the logging, timer reset, or setting manager
(initializing, backup, or restore) is in progress, retry
the memory format after nishing each command.
In the other cases, wait for a while, and then retry
to format the memory.
Storage space is getting low. If the remaining memory in the system area is
less than 100MB, this message is displayed every
minute.
Reset the ride log data.
Range of the valid value is XXX - YYY When you input the value outside a setting range,
this message is displayed.
Input the value within a setting range.
60

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Pioneer SGX-CA500S wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info